Page 71

S-Registers

S37, Desired Line Connection Speed Description Specifies the desired line connection speed.

Notes 1. When the Nn command is issued or the S37 register value is modified, the +MS command subparameters are updated to reflect the speed and modulation specified by the S37 value (see +MS, Select Modulation on page 1-34). For example: If N0 command is active, S37=10 updates the +MS command subparameters to reflect +MS=10,1,300,12000 If N1 command is active, S37=10 updates the +MS command subparameters to reflect +MS=10,0,12000,12000 2. S37 is not updated by the +MS command. 3. Use of the +MS command is recommended instead of the Nn and S37=x commands. Nn and S37=x commands are supported for compatibility with existing communication software. Default: 0 Bits 0-4 Desired line connection speed. This is interlinked with the Fn command. If an invalid number is entered, the number is accepted into the register, but S37 behaves as if the default value was entered. 0 = Attempt automode connection. If N0 is active, connection is attempted at the most recently sensed DTE speed (+MS command settings are updated to the appropriate values). If N1 is active, connection is attempted at the highest possible speed (+MS settings are updated to 11,1,300,1440 to reflect V.32bis automode, 300 bps minimum speed, and 14400 bps maximum speed) (default). 1-3 =Attempt to connect at 300 bps. F1 command 4 = Reserved. 5 = Attempt to connect at V.22 1200 bps. F4 command 6 = Attempt to connect at V.22 bis 2400 bps. F5 command

2-19

Page 72

CRD 1500 Modem/Charging Cradle Programmer’s Guide

7 = Attempt to connect at V.23. 8 = Attempt to connect at V.32 bis/V.32 4800 bps. F6 command 9 = Attempt to connect at V.32 bis/V.32 9600 bps. F8 command 10 = Attempt to connect at V.32 bis 12000 bps. F9 command 11 = Attempt to connect at V.32 bis 14400 bps. F10 command 12 = Attempt to connect at V.32 bis 7200 bps. F7 command Bits 5-7 Reserved

S38, Delay Before Forced Hang Up Description Specifies the delay between the modem's receipt of the H command to disconnect (or ONto-OFF transition of DTR if the modem is programmed to follow the signal), and the disconnect operation. Applicable to error-correction connection only. Use this register to ensure that data in the modem buffer is sent before the modem disconnects. 1. If S38 is set to a value between 0 and 254, the modem waits that number of seconds for the remote modem to acknowledge all data in the modem buffer before disconnecting. If time expires before all data is sent, the NO CARRIER result code is issued to indicate that data was lost. If all data is transmitted prior to time-out, the response to the H0 command is OK. 2. If S38 is set to 255, the modem does not time out and continues to attempt to deliver data in the buffer until the connection is lost or the data is delivered. Range:

0-255 seconds

Default: 20

2-20

Page 73

S-Registers

S39, Flow Control Bit Mapped Options Status Description Default: 3 (00000011b) Bits 0-2 Status of command options 0 = No flow control 3 = RTS/CTS (&K3) (default) 4 = XON/XOFF (&K4) 5 = Transparent XON (&K5) 6 = Both methods (&K6) Bits 3-7 Reserved

S40, General Bit Mapped Options Status Description Indicates the status of command options. Default: 104 (68h) (01101000b) Bits 0-1 MNP Extended Services (-Kn) 0 = Disable extended services (-K0) (default) 1 = Enable extended services (-K1) 2 = Enable extended services (-K2) Bit 2

Reserved

Bits 3-5 Break Handling (\Kn) 0 = \K0 1 = \K1 2 = \K2 3 = \K3 4 = \K4 5 = \K5 (default) Bits 6-7 MNP block size (\An) 0 = 64 chars (\A0) 1 = 128 chars (\A1) (default) 2-21

Page 74

CRD 1500 Modem/Charging Cradle Programmer’s Guide

2 = 192 chars (\A2) 3 = 256 chars (\A3)

S41, General Bit Mapped Options Status Description Indicates the status of command options. Default: 195 (C3h) (11000011b) Bits 0-1

Compression selection (%Cn) 0 = Disabled (%C0) 1 = MNP 5 (%C1) 2 = V.42 bis (%C2) 3 = MNP 5 and V.42 bis (%C3) (default)

Bits 2, 6 Auto retrain and fallback/fall forward (%En)

2-22

Bit 6

Bit 2

0

0 = Retrain and fallback/fall forward disabled (%E0)

0

1 = Retrain enabled (%E1)

1

0 = Fallback/fall forward enabled (%E2) (default)

Bit 3

Reserved

Bits 4-5

Reserved

Bit 7

Reserved

Page 75

S-Registers

S46, Data Compression Control Description Controls selection of compression. The following actions are executed for the given values: Range:

136 or 138

Default: 138 S46=136

Execute error correction protocol with no compression.

S46=138

Execute error correction protocol with compression (default).

S48, V.42 Negotiation Action Description The V.42 negotiation process determines the capabilities of the remote modem. However, when these capabilities are known and negotiation is unnecessary, this process can be bypassed. Range:

0, 7, or 128 If an invalid number is entered, it is accepted into the S-Register, but S48 behaves as if 128 was entered.

Default: 7 S48=0

Disable negotiation; bypass the detection and negotiation phases; and proceed with LAPM.

S48=7

Enable negotiation (default).

S48=128

Disable negotiation; bypass the detection and negotiation phases; and proceed at once with the fallback action specified in S36. Can be used to force MNP.

S82, Break Handling Options S82 is for compatibility purposes; changing this register has no affect.

2-23

Page 76

CRD 1500 Modem/Charging Cradle Programmer’s Guide

S86, Call Failure Reason Code Description When the modem issues a NO CARRIER result code, a value is written to this S-Register to help determine the reason for the failed connection. S86 records the first event that contributes to a NO CARRIER message. The cause codes are: Range:

0, 4, 5, 9, 12, 13, or 14

Default: S86=0

Normal disconnect, no error occurred.

S86=4

Loss of carrier.

S86=5

V.42 negotiation failed to detect an error-correction modem at the other end.

S86=9

The modems could not find a common protocol.

S86=12

Normal disconnect initiated by the remote modem.

S86=13

Remote modem does not respond after 10 re-transmissions of the same message.

S86=14

Protocol violation.

S95, Extended Result Codes Description The bits in this register can be set to override some of the Wn command options. A bit set to 1 in this register enables the corresponding result code regardless of the Wn setting. Default: 0

2-24

Bit 0

CONNECT result code indicates DCE speed instead of DTE speed.

Bit 1

Append/ARQ to CONNECT XXXX result code in error-correction mode (XXXX = rate).

Bit 2

Enable CARRIER XXXX result code (XXXX = rate).

Bit 3

Enable PROTOCOL XXXX result code (XXXX = protocol identifier).

Page 77

S-Registers

Bit 4

Reserved.

Bit 5

Enable COMPRESSION result code (XXXX = compression type).

Bit 6

Reserved.

Bit 7

Reserved.

2-25

Page 78

CRD 1500 Modem/Charging Cradle Programmer’s Guide

2-26