Chapter 2 S-Registers Table 2-1 summarizes the S-Registers and their default values. Use the &Wn command to store registers denoted with an '*' in one of the two user profiles. Use the Zn command to load any of these profiles. “Reserved” denotes registers reserved for current or future use by the firmware, or are permanently overridden by PTT limitations. All bit-mapped registers are read-only. Use the appropriate AT command that controls the relevant bits in the S-Register to change the value.
Factory Defaults The factory default values are stored in ROM and are loaded into the active configuration at power up or by the ATZn command. The designated default profile is subsequently loaded, and may change some of the factory default values. Use the &Yn command, where n is one of the two possible user profiles, to change the designated default profile. The defaults in the table are those in factory profiles zero and one. Enter the &Fn command at any time to load the factory default values.
2-1
Page 54
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Table 2-1. S-Register Summary Register
Function
Range
Units
Saved *
Default**
S0
Rings to Auto-Answer
0-255 rings
S1
Ring Counter
0-255 rings
S2
Escape Character
0-255
ASCII
S3
Carriage Return Character
0-127
ASCII
13
S4
Line Feed Character
0-127
ASCII
10
S5
Backspace Character
0-255
ASCII
8
S6
Wait Time for Dial Tone
2-255 s
*
4
S7
Wait Time for Carrier
1-255 s
*
50
S8
Pause Time for Dial Delay Modifier 0-255 s
*
2
S9
Carrier Detect Response Time
1-255
0.1 s
*
6
S10
Carrier Loss Disconnect Time
1-255
0.1 s
*
14
S11
DTMF Tone Duration
0.001 s
*
95
S12
Escape Prompt Delay
0-255
0.02 s
*
50
S13
Check Line Quiet Before Seize
0-1
-
S14
General Bit Mapped Options Status -
-
*
S15
Reserved
-
-
-
S16
Test Mode Bit Mapped Options Status (&T)
-
-
0
S17
Reserved
-
-
-
S18
Test Timer
0-255 s
S19
AutoSync Options
-
-
S20
AutoSync HDLC Address or BSC Sync Character
0-255
-
*
0
S21
V.24/General Bit Mapped Options Status
-
-
*
52 (34h)
0 *
43
1
*
138 (8Ah)
0 0
*Register value may be stored in one of two user profiles with the &W command.
2-2
1
Page 55
S-Registers
Table 2-1. S-Register Summary (continued) Register
Function
Range
Units
Saved
Default**
S22
Results Bit Mapped Options Status -
-
*
117 (75h)
S23
General Bit Mapped Options Status
-
*
62 (3Dh)
S24
Sleep Inactivity Timer
0-255 s
*
0
S25
Delay to DTR Off
0-255 s or 0.01 s
5
S26
RTS-to-CTS Delay
0-255
0.01 s
1
S27
General Bit Mapped Options Status -
-
*
73 (49h)
S28
General Bit-Mapped Options Status
-
-
*
0
S30
Disconnect Inactivity Timer
0-255
10 s
S31
General Bit-Mapped Options Status
-
-
*
S32
XON Character
0-255
ASCII
17 (11h)
S33
XOFF Character
0-255
ASCII
19 (13h)
S34-S35
Reserved
-
-
S36
LAPM Failure Control
-
-
*
7
S37
Line Connection Speed
-
-
*
0
S38
Delay Before Forced Hangup
0-255 s
S39
Flow Control Bit Mapped Options Status
-
-
*
3
S40
General Bit-Mapped Options Status
-
-
*
104 (68h)
S41
General Bit-Mapped Options Status
-
-
*
195 (C3h)
S42-S45
Reserved
-
-
S46
Data Compression Control
-
-
*
138
S48
V.42 Negotiation Control
-
-
*
7
S82
LAPM Break Control
-
-
0 194 (C2h)
-
20
-
128(40h)
*Register value may be stored in one of two user profiles with the &W command.
2-3
Page 56
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Table 2-1. S-Register Summary (continued) Register
Function
Range
Units
S86
Call Failure Reason Code
0-255
-
S95
Result Code Messages Control
-
-
Saved
Default** -
*
0
*Register value may be stored in one of two user profiles with the &W command.
S-Register Definitions S0, Number of Rings to Auto-Answer Description Sets the number of rings required before the modem automatically answers a call. Set to zero to disable auto-answer mode. Range:
0-255 rings
Default: 1
S1, Ring Counter Description S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an eight-second interval. Range:
0-255 rings
Default: 0
2-4
Page 57
S-Registers
S2, Escape Character Description Holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII '+'. A value over 127 disables the escape process, i.e., no escape character is recognized. Range:
0-255, ASCII decimal
Default: 43 (+)
S3, Carriage Return Character Description Sets the command line and result code terminator character. Pertains to asynchronous operation only. Range:
0-127, ASCII decimal
Default: 13 (Carriage Return)
S4, Line Feed Character Description Sets the character recognized as a line feed. Pertains to asynchronous operation only. The Line Feed control character is output after the Carriage Return control character if verbose result codes are used. Range:
0-127, ASCII decimal
Default: 10 (Line Feed)
2-5
Page 58
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S5, Backspace Character Description Sets the character recognized as a backspace. Pertains to asynchronous operation only. The modem does not recognize the Backspace character if it is set to a value greater than 32 ASCII. This character can be used to edit a command line. When the echo command is enabled, the modem echoes back to the local DTE the Backspace character, an ASCII space character, and a second Backspace character; therefore a total of three characters are transmitted each time the modem processes the Backspace character. Range:
0-32, ASCII decimal
Default: 8 (Backspace)
S6, Wait Time for Dial Tone Before Blind Dialing, or After “W” Dial Modifier Description Sets the length of time, in seconds, the modem waits before starting to dial after going offhook when blind dialing. This operation, however, may be affected by some ATX options according to country restrictions. The “Wait for Dial Tone” call progress feature (W dial modifier in the dial string) overrides the value in register S6. S6 also sets the length of time, in seconds, the modem waits for a dial tone when encountering a “W” dial modifier before returning a NO DIAL TONE result code. The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less than 2 seconds. Range:
2-255 seconds
Default: 4
2-6
Page 59
S-Registers
S7, Wait Time For Carrier After Dial, For Silence Description Sets the length of time, in seconds, the modem waits for carrier before hanging up. The timer is started when the modem finishes dialing (originate), or 2 seconds after going offhook (answer). In originate mode, the timer resets when an answer tone is detected, if allowed by country restrictions. S7 also sets the length of time, in seconds, the modem waits for silence when encountering the @ dial modifier before continuing with the next dial string parameter. Range:
1-255 seconds
Default: 50
S8, Pause Time For Dial Delay Description Sets the time, in seconds, the modem must pause when encountering the “,” dial modifier in the dial string. Range:
0-255 seconds
Default: 2
S9, Carrier Detect Response Time Description Sets the time, in tenths of a second, the carrier must be present before the modem considers it valid and turns on RLSD. As this time increases, there is less chance to detect a false carrier due to noise from the telephone line. Range:
1-255 tenths of a second
Default: 6 (0.6 second)
2-7
Page 60
CRD 1500 Modem/Charging Cradle Programmer’s Guide
S10, Lost Carrier To Hang Up Delay Description Sets the length of time, in tenths of a second, the modem waits before hanging up after a loss of carrier. This allows for a temporary carrier loss without causing the local modem to disconnect. When set to 255, the modem functions as if a carrier is always present. The actual interval the modem waits before disconnecting is the value in register S10 minus the value in register S9. Therefore, the S10 value must be greater than the S9 value or the modem disconnects before it recognizes the carrier. Range:
1-255 tenths of a second
Default: 14 (1.4 seconds)
S12, Escape Prompt Delay (EPD) Description Defines the maximum time, in fiftieths of a second, allowed between receipt of the last character of the three escape character sequence from the DTE, and sending of the OK result code to the DTE. If any characters are detected during this time, the OK is not sent. Note that sending of the OK result code does not affect entry into command mode. Range:
0-255 1/50 of a second
Default: 50 (1 second)
S13, Check Line Quiet before Line Seize Description Causes the modem to 'listen' to the line, in the high impedance state, prior to originating a call. If activity is detected, the modem does not seize the line, but responds 'NO DIALTONE' and remains in command mode. Activity is qualified by signals with a duration of 200ms or more. Silence is qualified as 3 seconds of inactivity. If this register is 0, the feature is inactive. If this register is non-zero, the feature is active. Range:
0-1
Default: 1
2-8
Page 61
S-Registers
S14, General Bit Mapped Options Status Description Indicates the status of command options. Default: 138 (8Ah) (10001010b) Bit 0
This bit is ignored.
Bit 1
Command echo (En) 0 = Disabled (E0) 1 = Enabled (E1) (default)
Bit 2
Quiet mode (Qn) 0 = Send result codes (Q0) (default) 1 = Do not send result codes (Q1)
Bit 3
Result codes (Vn) 0 = Numeric (V0) 1 = Verbose (V1) (default)
Bit 4
Reserved
Bit 5
Tone (T)/Pulse (P) 0 = Tone (T) (default) 1 = Pulse (P)
Bit 6
Reserved
Bit 7
Originate/Answer 0 = Answer 1 = Originate (default)
S15, Reserved
2-9