Page 45

AT Command Set

Third State A break is received from a remote modem during a non-error corrected connection: \K0

Clear data buffers and send break to the DTE.

\K1

Clear data buffers and send break to the DTE.

\K2

Send a break immediately to DTE.

\K3

Send a break immediately to DTE.

\K4

Send a break in sequence with received data to DTE.

\K5

Send a break in sequence with received data to DTE (default).

Result Codes OK n = 0 to 5

ERROR Otherwise

1-31

Page 46

CRD 1500 Modem/Charging Cradle Programmer’s Guide

\Nn, Operating Mode Description Controls the preferred error correcting mode to be negotiated in a subsequent data connection. \N0

Selects normal speed buffered mode (disables error-correction mode). (Forces &Q6.)

\N1

Selects direct mode and is equivalent to &M0, &Q0 mode of operation. (Forces &Q0.)

\N2

Selects reliable (error-correction) mode. The modem first attempts a LAPM connection, then an MNP connection. Failure to make a reliable connection causes the modem to hang up. (Forces &Q5, S36=4, and S48=7.)

\N3

Selects auto reliable mode. This is similar to \N2 except failure to make a reliable connection results in the modem falling back to the speed buffered normal mode. (Forces &Q5, S36=7, and S48=7.)

\N4

Selects LAPM error-correction mode. Failure to make an LAPM errorcorrection connection causes the modem to hang up. (Forces &Q5 and S48=0.) Note: The -K1 command can override the \N4 command.

\N5

Selects MNP error-correction mode. Failure to make an MNP error-correction connection causes the modem to hang up. (Forces &Q5, S36=4, and S48=128.)

Result Codes OK n = 0 to 5

ERROR Otherwise

1-32

Page 47

AT Command Set

AT+ Commands +GCI, Country Profiles Description The +GCI command functionality is in accordance with ITU V.250 and T.35 as follows: +GCI=xx Changes country code where xx is the T.35 code defined in the following table. The new country code is used after the next reset (either power or Z command). +GCI?

Returns the T.35 code for the active country.

+GCI=? Returns all the supported T.35 codes within the firmware. To improve compatibility with different drivers, the older Rockwell/ Conexant *NC format is also supported. The modem responds to either command format, but the ITU V.250 +GCI format is recommended for new code. *NCyy

Changes country code where yy is the code defined in the following table. The new country code is used after the next reset (either power or Z command). Setting may be checked with the I5 command for a response of 0yy. Table 1-2. Table of Country Codes according to ITU T.35

Country

+GCI=xx

*NCyy

Country

+GCI=xx

*NCyy

USA (default)

B5

22

Italy

59

08

Europe (see notes that FD follow)

55

Japan

00

43

Argentina

07

23

Malaysia

6C

26

Australia

09

40

Mexico

73

27

Austria

0A

01

Peru

88

28

Brazil

16

24

Portugal

8B

12

Canada

20

20

Singapore

9C

47

Chile

25

25

Spain

A0

13

Reserved for future Czek use

2E

50

Taiwan

FE

46

1-33

Page 48

CRD 1500 Modem/Charging Cradle Programmer’s Guide

Table 1-2. Table of Country Codes according to ITU T.35 (continued) Country

+GCI=xx

*NCyy

Greece

46

17

Reserved for future Hungary use

51

51

Country

+GCI=xx

Reserved for future AE Turkey use

*NCyy 14

European Notes 1. European-specific hardware is required. To avoid damage, use CRD1500-1000EU in Europe. 2. Both the USA (B5) and European (FD) codes contain the same settings; you may use the default B5 setting in Europe. The separate codes maintain compliance with ITU T.35 3. Pulse dialing characteristics vary in Europe. Countries that do not fully support tone dialing support pulse dialing using the specific Country Code instead of European (FD). 4. If you have problems with the modem, try the specific country setting.

+MS, Select Modulation Description This extended-format command selects the modulation and, optionally, enables or disables automode, specifies the lowest and highest connection rates, selects ?-Law or A-Law codec type, and enables or disables robbed bit signaling generation (server modem) or detection (client modem) using one to five subparameters. The command format is: +MS= <mod> [,[<automode>][,[<min_rate>][,[<max_rate>] [,[<x_law>][,[< rb_signaling>]]]]]]<CR>

Notes 1. For 14400 bps and lower speeds, the Nn command and S37 register can alternatively be used, where the +MS subparameters are modified to reflect the Nn and S37=x settings. Use of the Nn and S37=x commands is not recommended but is provided for compatibility with existing communication software. (The +MS command does not update S37.)

1-34

Page 49

AT Command Set

2. Subparameters not entered (enter a comma only or <CR> to skip the last subparameter) remain at their current values.

Reporting Selected Options The modem can send a string of information to the DTE consisting of selected options using the following command: +MS? The response is: +MS: <mod>,<automode>,<min_rate>,<max_rate>,<x_law>,<rb_signaling> For example: +MS: 56,1,300,56000,0,0 +MS: 11,1,300,33600,0,0 +MS: 10,1,300,14400,0,0

Reporting Supported Options The modem can send a string of information to the DTE consisting of supported options using the following command: +MS=? The response is: +MS:

(list of supported <mod> values), (list of supported <automode> values), (list of supported <min_rate> values), (list of supported <max_rate> values), (list of supported <x_law> values), (list of supported <rb_signaling> values)

For example: +MS:

(0,1,2,3,9,10,64,69),(0,1),(300-14400),(300-14400),(0,1),(0,1)

1-35

Page 50

CRD 1500 Modem/Charging Cradle Programmer’s Guide

Subparameter Definitions <mod> A decimal number which specifies the preferred modulation (automode enabled) or the modulation (automode disabled) to use in originating or answering a connection. The options are: Table 1-3. Modulation Rates <mod>

Modulation

Possible Rates (bps) 1

0

V.21

300

1

V.22

1200

2

V.22 bis

2400 or 1200

3

V.23

1200

9

V.32

9600 or 4800

10

V.32 bis

14400, 12000, 9600, 7200, or 4800

64

Bell 103

300

69

Bell 212

1200

Notes

See Note 2???

Default for RC144

Note: See optional <automode>, <min_rate>, and <max_rate> subparameters

The modem may also automatically switch to another modulation (automode), subject to the following constraints:

1-36

•

The modem may not be able to automatically switch from certain modulations (specified by <mod>). For example, there is no standard way to automode from Bell 103 to V.23.

•

The DTE may disable automode operation (see <automode> below).

•

The DTE may constrain the range of modulations available by specifying the lowest and highest rates (see <min_rate> and <max_rate>).

Page 51

AT Command Set

<automode> an optional numeric value which enables or disables automatic modulation negotiation using V.8 bis/V.8 or V.32 bis Annex A. The options are: 0

Automode disabled

1

Automode enabled using V.8 bis/V.8 or V.32 Annex A (default)

The default value is 1, which enables automode. However, there are modulations for which there is no automatic negotiation, e.g., Bell 212 (<mod> = 69). For <automode> = 0 (automode disabled, i.e., fixed modulation): •

If <max_rate> is within the rates supported by the selected modulation, the selected rate is that specified by <max_rate>. For example: +MS=10,0,1200,4800 selects V.32 bis 4800 bps fixed rate.

•

If <max_rate> is greater than the highest speed supported by the modulation specified by <mod>, the starting rate is the highest rate supported by the selected modulation. For example: +MS=10,0,2400,14400 selects V.32 bis 14400, 12000, 9600, 7200, or 4800 bps.

•

To emulate the N0S37=x command sequence to select fixed mode operation, set the <max_rate> and <min_rate> to the same requested speed, and <mod> to be the modulation for that speed. For example: +MS=10,0,12000,12000 selects V.32 bis 12000 bps fixed mode (as in N0S37=10).

For <automode> = 1 (automode enabled, i.e., automatically selected speed and modulation), the modem connects at the highest possible rate in accordance with V.8 bis/V.8, or V.32 bis Annex A if V.8 bis/V.8 is not supported by the remote modem. •

If <max_rate> is greater than the highest rate supported by the modulation specified by <mod>, the modem automodes down from the highest rate of the selected modulation. For example: +MS=10,1,1200,24000 selects automoding down from V.32 bis 14400 bps.

•

To emulate the N1S37=x sequence command, set the modulation and the rate to start automoding down from using <mod> and <max_rate>, respectively. Set <min_rate> to 300 to allow automoding down to V.21 300 bps. For example: +MS=9,1,300,12000 selects automode starting at V.32 bis 12000 bps (same as N1S37=10).

1-37

Page 52

CRD 1500 Modem/Charging Cradle Programmer’s Guide

<min_rate> an optional number which specifies the lowest rate at which the modem may establish a connection. The value is decimal coded, in units of bps, e.g., 2400 specifies the lowest rate to be 2400 bps. <max_rate> an optional number which specifies the highest rate at which the modem may establish a connection. The value is decimal coded, in units of bps, e.g., 14400 specifies the highest rate to be 14400 bps. The default is 28800 for 28800 bps. <x_law> an optional number which specifies the codec type. The options are: •

0 = ?-Law

•

1 = A-Law

Note that ATZ resets the <x_law> selection to 0 (?-Law). <rb_signalling> an optional number which enables or disables robbed bit signalling generation in a server modem or enables or disables robbed bit signalling detection in a client modem. The options are: •

0 = Robbed bit signalling generation (server modem) or detection (client modem) disabled (default)

•

1 = Robbed bit signalling generation (server modem) or detection (client modem) enabled

Note that ATZ resets the <rb_signalling> selection to 0 (disabled).

Result Codes OK

Valid subparameter string

ERROR Otherwise

1-38