Page 35

AT Command Set

Result Codes OK n = 0 to 6

ERROR Otherwise

&Rn, RTS/CTS Option Description Selects how the modem controls CTS. CTS operation is modified if hardware flow control is selected (see &Kn, Flow Control on page 1-19 command). The parameter value, if valid, is written to S21 bit 2. &R0

CTS tracks the state of RTS; S26 defines the RTS-to-CTS delay. CTS turns OFF if required by flow control.

&R1

CTS is normally ON (RTS transitions are ignored) and turns OFF only if required by flow control.

Result Codes OK n = 0 or 1

ERROR Otherwise

&Tn, Test and Diagnostics Description Performs selected test and diagnostic functions according to the parameter supplied. A test can be run only when in an asynchronous operation in non-error-correction mode (normal or direct mode). To terminate a test in progress, enter the escape sequence first, except for parameters 7 and 8 (see Chapter 2, S-Registers). If S18 is non-zero, a test terminates after the time specified by S18 and displays the OK message. For tests 3, 6, and 7, a connection between the two modems must be established. &T0

Terminates test in progress. Clears S16.

&T1

Initiates local analog loopback, V.54 Loop 3. Sets S16 bit 0. If a connection exists when this command is issued, the modem hangs up. The CONNECT XXXX message appears upon the start of the test.

&T2

Returns ERROR. 1-21

Page 36

CRD 1500 Modem/Charging Cradle Programmer’s Guide

&T3

Initiates local digital loopback, V.54 Loop 2. Sets S16 bit 2. If no connection exists, ERROR is returned. Sets S16 bit 4 when the test is in progress.

&T4

Enables digital loopback acknowledgment for remote request, i.e., an RDL request from a remote modem is allowed. Sets S23 bit 0.

&T5

Disables digital loopback acknowledgment for remote request, i.e., an RDL request from a remote modem is denied. Clears S23 bit 0. (Default.)

&T6

Requests a remote digital loopback (RDL), V.54 Loop 2, without self test. If no connection exists, ERROR is returned. Sets S16 bit 4 when the test is in progress. The CONNECT XXXX message appears upon the start of the test.

&T7

Requests a remote digital loopback (RDL),V.54 Loop 2, with self test. (In self test, a test pattern is looped back and checked by the modem.) If no connection exists, ERROR is returned. When the test is terminated either via expiration of S18, or via the &T0 or H command, the number of detected errors is reported to the DTE. Sets S16 bit 5 when the test is in progress.

&T8

Initiates local analog loopback, V.54 Loop 3, with self test. (In self test, a test pattern is looped back and checked by the modem.) If a connection exists, the modem hangs up before the test is initiated. When the test is terminated either via expiration of S18, or via the &T0 or H command, the number of detected errors is reported to the DTE. Sets S16 bit 6 when the test is in progress. This command may not be available in some countries due to PTT restrictions.

1-22

Page 37

AT Command Set

&V, Display Current Configuration and Stored Profiles Description Reports the current (active) configuration, the stored (user) profiles, and the first four stored telephone numbers.

Result Code OK

Example AT&V ACTIVE PROFILE: B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0 S00:002 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:030 S08:002 S09:006 S10:014 S11:255 S12:050 S18:000 S25:005 S26:001 S36:007 S37:000 S38:020 S46:138 S48:007 S95:000 STORED PROFILE 0: B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S36:007 S37:000 S40:105 S41:003 S46:138 S95:000 STORED PROFILE 1: B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S36:007 S37:000 S40:105 S41:003 S46:138 S95:000 TELEPHONE NUMBERS: 0=1= 2=3= OK

1-23

Page 38

CRD 1500 Modem/Charging Cradle Programmer’s Guide

&V1, Display Last Connection Statistics Description Displays the last connection statistics in the following format (shown with typical results): TERMINATION REASON

LINK DISCONNECT or LOCAL REQUEST

LAST TX data rate

14400 BPS

HIGHEST TX data rate

14400 BPS

LAST RX data rate

14400 BPS

HIGHEST RX data rate

14400 BPS

Error correction PROTOCOL

LAPM

Data COMPRESSION

V42Bis

Line QUALITY

030

Highest SPX RX state

068

Highest SPX TX state

067

&Wn, Store Current Configuration Description Saves the current (active) configuration (profile), including S-Registers, in one of the two user profiles in NVRAM as denoted by the parameter value. The current configuration contains a list of storable parameters illustrated in the &V command. These settings are restored to the active configuration upon receiving an Zn command or at power up (see &Yn, Designate a Default Reset Profile on page 1-25 command). &W0

Stores the current configuration as profile 0.

&W1

Stores the current configuration as profile 1.

Result Codes OK

1-24 n = 0 or 1

Page 39

AT Command Set

ERROR Otherwise

&Yn, Designate a Default Reset Profile Description Selects which user profile is used after a hard reset. &Y0

The modem uses profile 0.

&Y1

The modem uses profile 1.

Result Codes OK n = 0 to 1

ERROR If n > 1, or if NVRAM is not installed or is not operational

&Zn=x, Store Telephone Number Description The modem can store up to four telephone numbers. Each telephone number dial string can contain up to 34 digits. &Zn=x n = 0 to 3 and x = dial string.

Result Codes OK

For n ??3, and x ??34 digits

ERROR If n > 3, x > 35 digits

1-25

Page 40

CRD 1500 Modem/Charging Cradle Programmer’s Guide

AT% Commands %C, Enable/Disable Data Compression Description Enables or disables data compression negotiation. The modem can only perform data compression on an error corrected link. The parameter value, if valid, is written to S41 bits 0 and 1. %C0

Disables data compression. Resets S46 bit 1.

%C1

Enables MNP 5 data compression negotiation. Resets S46 bit 1.

%C2

Enables V.42 bis data compression. Sets S46 bit 1.

%C3

Enables both V.42 bis and MNP 5 data compression. Sets S46 bit 1 (default).

Result Codes OK n = 0, 1, 2, or 3

ERROR Otherwise

%En - Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall Forward Description Controls whether the modem automatically monitors the line quality and requests a retrain (%E1), or falls back when line quality is insufficient and forward when line quality is sufficient (%E2). The parameter value, if valid, is written to S41 bits 2 and 6. If enabled, the modem attempts to retrain for a maximum of 30 seconds. %E0

Disables line quality monitor and auto-retrain.

%E1

Enables line quality monitor and auto-retrain.

%E2

Enables line quality monitor and fallback/fall forward (default).

Result Codes OK 1-26 n = 0, 1, or 2

Page 41

AT Command Set

ERROR Otherwise Fallback/Fall Forward: When %E2 is active, the modem monitors the line quality (EQM). When line quality is insufficient, the modem initiates a rate re-negotiation to a lower speed within the V.32 bis/V.32 modulation speeds. The modem continues to fall back within the current modulation if necessary until the speed reaches 4800 bps. Below this rate, the modem only retrains if EQM thresholds are exceeded. If the 4800 bps. EQM is sufficient for at least one minute, the modem initiates a rate re-negotiation to a higher speed within the current modulation speeds. Rate renegotiations are done without a retrain if a V.32 bis connection is established. Speeds attempted during fallback/fall forward are those available in the rate sequences exchanged during the initial connection. Fallback/fall forward is available in error correction and normal modes, but not in direct mode or synchronous mode with external clocks.

%L, Line Signal Level Description Returns a value which indicates the received signal level. This value is a comparable indication of the receive level.

Result Codes OK

%Q, Line Signal Quality Description Reports the line signal quality. Returns the higher order byte of the EQM value. Based on the EQM value, retrain or fallback/fall forward may be initiated if enabled by %E1 or %E2.

Example AT%Q 015

Result Codes OK

If connected

ERROR If not connected, or connected in 300 bps, V.23, or fax modes

1-27

Page 42

CRD 1500 Modem/Charging Cradle Programmer’s Guide

AT\ Commands \An, Select Maximum MNP Block Size Description The modem operates an MNP error corrected link using a maximum block size controlled by the parameter supplied. The parameter value, if valid, is written to S40 bits 6 and 7. \A0

64 characters

\A1

128 characters (default)

\A2

192 characters

\A3

256 characters

Result Codes OK n = 0 to 3

ERROR Otherwise

\Bn, Transmit Break to Remote Description In non-error correction mode, the modem transmits a break signal to the remote modem with a length in multiples of 100 ms according to parameter specified. If a number greater than 9 is entered, 9 is used. The command works in conjunction with the \K command. In error correction mode, the modem signals a break through the active error correction protocol, giving no indication of the length. \B1-\B9 Break length in 100 ms units (default = 3) (non-error corrected mode only.)

Result Codes OK

If connected in data modem mode

NO CARRIER If not connected or connected in fax modem mode

1-28

Page 43

AT Command Set

Note When the modem receives a break from the remote modem, break is passed to the DTE as follows: •

In non-error correction mode direct, the break length is passed

•

In non-error correction mode normal and in error correction mode, a 300 ms break is passed.

\Kn, Break Control Description Controls the response of the modem to a break received from the DTE or the remote modem, or the \B command according to the parameter supplied. The parameter value, if valid, is written to S40 bits 3, 4, and 5. The response is different in three separate states.

First State The modem receives a break from the DTE when the modem is operating in data transfer mode: \K0

Enter on-line command mode, no break sent to the remote modem.

\K1

Clear data buffers and send break to remote modem.

\K2

Enter on-line command mode, no break sent to the remote modem.

\K3

Send break to remote modem immediately.

\K4

Enter on-line command mode, no break sent to the remote modem.

\K5

Send break to remote modem in sequence with transmitted data (default).

Second State The modem is in the on-line command state (waiting for AT commands) during a data connection, and the \B is received in order to send a break to the remote modem: \K0

Clear data buffers and send break to remote modem.

\K1

Clear data buffers and send break to remote modem.

\K2

Send break to remote modem immediately.

\K3

Send break to remote modem immediately.

1-29

Page 44

CRD 1500 Modem/Charging Cradle Programmer’s Guide

\K4

Send break to remote modem in sequence with data.

\K5

Send break to remote modem in sequence with data (default).

1-30