The text of a manual · part 5 of 11
CRD 1500 Modem/Charging Cradle Programmer's Guide: Chapter 1 AT Command Set, pages 25 to 34
Pages 25 to 34 of 84, from CRD 1500 Modem/Charging Cradle Programmer's Guide
The original document is the PDF (717 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CRD1500-1000
Page 25
AT Command Set
In some cases, writing to the S-Register appears to be accepted but the value is not written. Some commands are accepted, but the value may be limited and replaced by a maximum or minimum value.
T, Set Tone Dial Default Description Forces DTMF dialing until the next P dial modifier or P command is received. The modem sets an S-Register bit to conduct all subsequent dialing in tone mode. The DP command overrides this command. Clears S14 bit 5.
Result Code OK
Vn, Result Code Form Description Selects whether short-form or long-form result codes are sent to the DTE. The parameter, if valid, is written to S14 bit 3. V0
Enables short-form (terse) result codes. Line feed is not issued before a shortform result code.
V1
Enables long-form (verbose) result codes (default).
Result Codes OK n = 0 or 1
ERROR Otherwise
1-11
Page 26
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Wn, Connect Message Control Description Controls the format of CONNECT messages. The parameter value, if valid, is written to S31 bits 2 and 3. Note that register S95 bits can override the Wn command (see S95, Extended Result Codes on page 2-24). W0
Upon connection, the modem reports only the DTE speed (e.g., CONNECT 19200). Subsequent responses are disabled (default).
W1
Upon connection, the modem reports the line speed, the error correction protocol, and the DTE speed, respectively. Subsequent responses are disabled.
W2
Upon connection, the modem reports the DCE speed (e.g., CONNECT 14400). Subsequent responses are disabled.
Result Codes OK n = 0, 1, or 2
ERROR Otherwise
Xn, Extended Result Codes Description Selects which subset of the result messages are used by the modem to inform the DTE of the results of commands. Due to the many network tones available, varying by region and PBX, it may be necessary to blind dial. To enforce dial tone detection, place a “W” in the dial string (see Dn, Dial on page 1-4 command). Table 1-1 on page 1-13 indicates the messages enabled for each X value. X0
1-12
Disables monitoring of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, and NO ANSWER result codes. If busy tone detection is enforced and busy tone is detected, NO CARRIER is reported. If dial tone detection is enforced or selected and dial tone is not detected, NO CARRIER is reported instead of NO DIAL TONE. The value 000b is written to S22 bits 6, 5, and 4, respectively.
Page 27
AT Command Set
X1
Disables monitoring of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER, and CONNECT XXXX (XXXX = rate). If busy tone detection is enforced and busy tone is detected, NO CARRIER is reported instead of BUSY. If dial tone detection is enforced or selected and dial tone is not detected, NO CARRIER is reported instead of NO DIALTONE. The value 100b is written to S22 bits 6, 5, and 4, respectively.
X2
Disables monitoring of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO DIALTONE, NO ANSWER, and CONNECT XXXX. If busy tone detection is enforced and busy tone is detected, NO CARRIER is reported instead of BUSY. If dial tone detection is enforced or selected and dial tone is not detected, NO DIALTONE is reported instead of NO CARRIER. The value 101b is written to S22 bits 6, 5, and 4, respectively.
X3
Enables monitoring of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER, and CONNECT XXXX. If dial tone detection is enforced and dial tone is not detected, NO CARRIER is reported. The value 110b is written to S22 bits 6, 5, and 4, respectively.
X4
Enables monitoring of busy tones; send all messages. The value 111b is written to S22 bits 6, 5, and 4, respectively (default).
See also S13, Check Line Quiet before Line Seize on page 2-8 regarding use of No Dialtone.
Result Codes OK n = 0 to 4
ERROR Otherwise Table 1-1. Result Codes n Value in ATXn Command Short Form
Long Form
0
1
2
3
4
0
OK x x x x x
1
CONNECT x x x x x
Note: 'x' indicates the message (either the long form if verbose, or the value only for short form) is generated when that particular value of 'n' (at the top of the column) is selected via ATXn. If the column is blank, no message is generated for that option. A numeral indicates which less explicit message (verbose or short form) is output for that option. (See Chapter 2, S-Registers).
1-13
Page 28
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Table 1-1. Result Codes (continued) n Value in ATXn Command Short Form
Long Form
0
1
2
3
4
2
RING x x x x x
3
NO CARRIER x x x x x
4
ERROR x x x x x
5
CONNECT 1200
1 x x x x
6
NO DIALTONE
3
3 x x x
7
BUSY
3
3
3 x x
8
NO ANSWER x x x x x
9
CONNECT 0600
1 x x x x
10
CONNECT 2400
1 x x x x
11
CONNECT 4800
1 x x x x
12
CONNECT 9600
1 x x x x
13
CONNECT 7200
1 x x x x
14
CONNECT 12000
1 x x x x
15
CONNECT 14400
1 x x x x
16
CONNECT 19200
1 x x x x
17
CONNECT 38400
1 x x x x
18
CONNECT 57600
1 x x x x
19
CONNECT 115200
1 x x x x
22
CONNECT 75TX/1200RX
1 x x x x
23
CONNECT 1200TX/75RX
1 x x x x
24
DELAYED
4
4
4
4 x
32
BLACKLISTED
4
4
4
4 x
Note: 'x' indicates the message (either the long form if verbose, or the value only for short form) is generated when that particular value of 'n' (at the top of the column) is selected via ATXn. If the column is blank, no message is generated for that option. A numeral indicates which less explicit message (verbose or short form) is output for that option. (See Chapter 2, S-Registers).
1-14
Page 29
AT Command Set
Table 1-1. Result Codes (continued) n Value in ATXn Command Short Form
Long Form
0
1
2
3
4
33
FAX x x x x x
35
DATA x x x x x
40
CARRIER 300 x x x x x
44
CARRIER 1200/75 x x x x x
45
CARRIER 75/1200 x x x x x
46
CARRIER 1200 x x x x x
47
CARRIER 2400 x x x x x
48
CARRIER 4800 x x x x x
49
CARRIER 7200 x x x x x
50
CARRIER 9600 x x x x x
51
CARRIER 12000 x x x x x
52
CARRIER 14400 x x x x x
66
COMPRESSION: CLASS 5 x x x x x
67
COMPRESSION: V.42 bis x x x x x
69
COMPRESSION: NONE x x x x x
70
PROTOCOL: NONE x x x x x
77
PROTOCOL: LAPM x x x x x
80
PROTOCOL: ALT x x x x x
81
PROTOCOL: ALT-CELLULAR x x x x x
+F4
+FCERROR x x x x x
Note: 'x' indicates the message (either the long form if verbose, or the value only for short form) is generated when that particular value of 'n' (at the top of the column) is selected via ATXn. If the column is blank, no message is generated for that option. A numeral indicates which less explicit message (verbose or short form) is output for that option. (See Chapter 2, S-Registers).
1-15
Page 30
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Yn, Long Space Disconnect Description Enables/disables the generation and response to long space disconnect. The parameter value, if valid, is written to S21 bit 7. Y0
Disables long space disconnect (default).
Y1
Enables long space disconnect. In non-error correction mode, the modem sends a long space of four seconds before going on-hook, and responds to the receipt of a long space (i.e., a break signal greater than 1.6 seconds) by going on-hook.
Result Codes OK n = 0 or 1
ERROR Otherwise
Zn, Soft Reset and Restore Profile Description Performs a soft reset and restores (recalls) the configuration profile according to the parameter supplied. If no parameter is specified, zero is assumed. Z0
Soft reset and restore stored profile 0
Z1
Soft reset and restore stored profile 1
Result Codes OK n = 0 or 1
ERROR Otherwise
1-16
Page 31
AT Command Set
AT& Commands &Dn, DTR Option Description Interprets the ON to OFF transition of the DTR signal from the DTE according to the parameter supplied. The parameter value, if valid, is written to S21 bits 3 and 4. See S25, Delay To DTR on page 2-15. &D0
&D1
&D2
DTR drop is interpreted according to the current &Qn setting as follows: &Q0, &Q5, &Q6
DTR is ignored (assumed ON). Allows operation with DTEs which do not provide DTR.
&Q1, &Q4
DTR drop causes the modem to hang up. Auto-answer is not affected.
&Q2, &Q3
DTR drop causes the modem to hang up. Auto-answer is inhibited.
DTR drop is interpreted according to the current &Qn setting as follows: &Q0, &Q1, &Q4, &Q5, &Q6
The modem as if the asynchronous escape sequence was entered, and returns to asynchronous command state without disconnecting.
&Q2, &Q3
DTR drop causes the modem to hang up. Auto-answer is inhibited.
DTR drop is interpreted according to the current &Qn setting as follows: &Q0 through &Q6 DTR drop causes the modem to hang up. Auto-answer is inhibited (default).
&D3
DTR drop is interpreted according to the current &Qn setting as follows: &Q0, &Q1, &Q4, &Q5, &Q6
DTR drop causes the modem to perform a soft reset as if the Z command were received. The &Y setting determines which profile is loaded.
&Q2, &Q3
DTR drop causes the modem to hang up. Auto-answer is inhibited.
If &Q5, &Q6, is in effect, the action taken is the same as for &Q0.
1-17
Page 32
CRD 1500 Modem/Charging Cradle Programmer’s Guide
&Fn, Restore Factory Configuration (Profile) Description Loads the factory default configuration (profile). The factory defaults are identified for each command and in the S-Register descriptions. A configuration (profile) consists of a subset of S-Registers. &F0
Restore factory configuration 0
&F1
Restore factory configuration 1
Result Codes OK ERROR If the modem is connected
&Gn, Select Guard Tone Description Generates the guard tone selected by this command according to the parameter supplied (DPSK modulation modes only). The parameter value, if valid, is written to S23 bits 6 and 7. &G0
Disables guard tone
&G1
Disables guard tone
&G2
Selects 1800 Hz guard tone (default)
Result Codes OK n = 0 to 2
ERROR Otherwise
1-18
Page 33
AT Command Set
&Kn, Flow Control Description Defines the DTE/DCE (terminal/modem) flow control mechanism. The parameter value, if valid, is written to S39 bits 0, 1, and 2. &K0
Disables flow control
&K3
Enables RTS/CTS flow control
&K4
Enables XON/XOFF flow control
&K5
Enables transparent XON/XOFF flow control
&K6
Enables both RTS/CTS and XON/XOFF flow control
Result Codes OK n = 0, 3, 4, 5, or 6
ERROR Otherwise
&Mn, Asynchronous/Synchronous Mode Selection Description Determines the DTR operating mode. The modem treats the &M command as a subset of the &Q command. &M0
Selects direct asynchronous operation. Note that the command sequence &M0\N0 selects normal buffered mode, but the command sequence \N0&M0 selects direct mode. This is because the \N0 command is analogous to the &Q6 command. The value 000b is written to S27 bits 3, 1, and 0, respectively (See &Qn, Sync/Async Mode on page 1-20).
Result Codes OK n=0
ERROR Otherwise
1-19
Page 34
CRD 1500 Modem/Charging Cradle Programmer’s Guide
&Qn, Sync/Async Mode Description This command is an extension of the &M command and controls the connection modes permitted. It is used in conjunction with S36 and S48. (See Nn, Automode Enable on page 1-8.) When the &Q0 to &Q4 command is issued to select the mode, the subsequent connect message reports the DCE speed regardless of the W command and S95 settings. &Q0
Selects direct asynchronous operation. The value 000b is written to S27 bits 3, 1, and 0, respectively. See &Mn, Asynchronous/Synchronous Mode Selection on page 1-19.
&Q4
Selects AutoSync operation. The value 100b is written to S27 bits 3, 1, and 0, respectively.
AutoSync operation, when used in conjunction with the Hayes Synchronous Interface (HSI) capability in the DTE, provides synchronous communication capability from an asynchronous terminal. Starting AutoSync: Set registers S19, S20, and S25 to the desired values before selecting AutoSync operation with &Q4. After the CONNECT message is issued, the modem waits the period of time specified by S25 before examining DTR. If DTR is on, the modem enters the synchronous operating state; if DTR is off, the modem terminates the line connection and returns to the asynchronous command state. Stopping AutoSync: AutoSync operation stops when the carrier is lost, or DTR transitions from on-to-off. Loss of carrier returns the modem to the asynchronous command state. An on-to-off transition of DTR returns the modem to the asynchronous command state and either does not terminate the line connection (&D1 active) or terminates the line connection (any other &Dn command active). &Q5
The modem tries to negotiate an error-corrected link. Use S36 to configure the modem to determine whether a failure will return the modem on-hook, or will cause the modem to fallback to an asynchronous connection. The value 101b is written to S27 bits 3, 1, and 0, respectively (default).
&Q6
Selects asynchronous operation in normal mode (speed buffering). The value 110b is written to S27 bits 3, 1, and 0, respectively.
1-20