The text of a manual · part 4 of 11
CRD 1500 Modem/Charging Cradle Programmer's Guide: Chapter 1 AT Command Set, pages 15 to 24
Pages 15 to 24 of 84, from CRD 1500 Modem/Charging Cradle Programmer's Guide
The original document is the PDF (717 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CRD1500-1000
Page 15
Chapter 1 AT Command Set Introduction The Symbol MCDA Modem Card is used internally within the CRD1500-1000MC and CRD1500-1000EU. The 14.400kbps (V32bis) modem has additional Data Compression (MNP5, V42bis) for faster throughput to take advantage of the higher serial port speeds to the SPT1500. Error Correction (MNP4, V42) is also included. This chapter describes AT commands for the modem, along with parameters applicable to each command. The defaults for each configuration command are those used in the factory profile 0.
1-1
Page 16
CRD 1500 Modem/Charging Cradle Programmer’s Guide
AT Commands A/, Re-execute Command Description The modem behaves as if the DTE has re-sent the last command line. “A/” repeats all commands in the command buffer. This command re-executes a call (using the Dial command) that failed to connect due to a busy line, no answer, or a wrong number, and must appear alone on a command line. Do not terminate with a carriage return.
AT= x, Write to Selected S-Register Description Writes the value x to the currently selected S-Register. Use the ATSn command to select an S-Register. All S-Registers return OK if x is a number. Some registers may not be written due to country-specific PTT limitations.
Result Codes OK
For all arguments
AT?, Read Selected S-Register Description Reads and displays the selected S-Register. Use the ATSn command to select an SRegister.
Result Codes OK
For all arguments
A, Answer Description The modem goes off-hook and attempts to answer an incoming call if proper conditions are met. When answer handshake is complete, the modem goes on-line in answer mode.
1-2
Page 17
AT Command Set
Bn, CCITT or Bell Description When configured to allow either option, the modem selects Bell or CCITT modulation for a line speed connection of 300 or 1200 bps according to the parameter supplied. Any other line speed uses a CCITT modulation standard. The parameter value, if valid, is written to S27 bit 6. (See Fn, Select Line Modulation on page 1-6.) B0
Selects CCITT operation at 300 or 1200 bps during Call Establishment and a subsequent connection.
B1
Selects BELL operation at 300 or 1200 bps during Call Establishment and a subsequent connection.
Result Codes OK n = 0 or 1
ERROR Otherwise
Cn, Carrier Control Description Included for compatibility only, and has no effect other than returning a result code. The only valid parameter is 1.
Result Codes OK n=1
ERROR Otherwise
1-3
Page 18
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Dn, Dial Description Directs the modem to go on-line, dial according to the string entered, and attempt to establish a connection. If no dial string is supplied, the modem goes on-line and attempts the handshake in originate mode.
Note If the ATD command is issued before the S1 register clears, the modem responds with the NO CARRIER result code.
Dial Modifiers Valid dial string parameters follow. Punctuation characters may be used for clarity; parentheses, hyphen, and spaces are ignored. 0-9
DTMF digits 0 to 9.
*
The 'star' digit (tone dialing only).
#
The 'gate' digit (tone dialing only).
A-D
DTMF digits A, B, C, and D.
L
Re-dial last number: the modem re-dials the last valid telephone number. The L appears immediately after the D; characters that follow are ignored.
P
Select pulse dialing: pulse dial the numbers that follow until “T” is encountered. Affects current and subsequent dialing. Pulse dialing is not fitted on standard European model CRD1500-100M-01.
T
Select tone dialing: tone dial the numbers that follow until “P” is encountered. Affects current and subsequent dialing.
R
This command is accepted but not acted on.
S=n
Dial the number stored in the directory (n = 0 to 3) (see &Zn=x, Store Telephone Number on page 1-25).
W
Wait for dial tone: the modem waits for a dial tone before dialing the digits following “W”. If a dial tone is not detected within the time specified by S6, the modem aborts the sequence, returns on-hook, and generates an error message.
1-4
Page 19
AT Command Set
@
Wait for silence: the modem waits for at least 5 seconds of silence in the call progress frequency band before continuing with the next dial string parameter. If the modem does not detect the silence before the expiration of the call abort timer (S7), the modem terminates the call attempt with a NO ANSWER message. If busy detection is enabled, the modem may terminate the call with the BUSY result code. If an answer tone arrives during execution of this parameter, the modem handshakes.
,
Dial pause: the modem pauses for a time specified by S8 before dialing the digits following “,”.
;
Return to command state: Added to the end of a dial string, returns the modem to the command state after processing the portion of the dial string preceding the “;”. This allows you to issue additional AT commands while remaining off-hook. Place these commands in the original command line following the “;” and/or on subsequent command lines. The modem enters call progress only after an additional dial command is issued without the “;” terminator. Use “H” to abort the dial in progress, and go back on-hook.
()
Ignored: may be used to format the dial string.
-
Ignored: may be used to format the dial string.
<space> Ignored: may be used to format the dial string. <i>
Invalid character: ignored.
En, Command Echo Description Enables or disables the echo of characters to the DTE according to the parameter supplied. The parameter value, if valid, is written to S14 bit 1. E0
Disables command echo
E1
Enables command echo (default)
Result Codes OK n = 0 or 1
ERROR Otherwise
1-5
Page 20
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Fn, Select Line Modulation Description Selects the line modulation according to the parameter supplied. The line modulation is fixed unless Automode is selected. This command interacts with the S37 and the N command. The parameter value, if valid, is written to S37 bits 0-4. To select line modulation, we recommend that either the F command, or a combination of the S37 and the N command be used, but not both. F0
Selects auto-detect mode. Sets N1 and sets S31 bit 1. In this mode, the modem configures for automode operation. All connect speeds supported by the modem are possible according to the remote modem's preference. The contents of S37 are ignored, as well as the sensed DTE speed.
F1
Selects V.21 or Bell 103 according to the B setting as the only acceptable line speed resulting in a subsequent connection. Sets N0, sets S37 to 1, and clears S31 bit 1. This command is equivalent to command string ATN0S37=1.
F2
Not supported.
F3
Selects V.23 as the only acceptable line modulation for a subsequent connection. Originator is at 75 bps and answerer is at 1200 bps. Sets N0, sets S37 to 7, and clears S31 bit 1. This command is equivalent to command string ATN0S37=7.
F4
Selects V.22 1200 or Bell 212A according to the B command setting as the only acceptable line speed for a subsequent connection. Sets N0, sets S37 to 5, and clears S31 bit 1. This command is equivalent to command string ATN0S37=5.
F5
Selects V.22 bis as the only acceptable line modulation for a subsequent connection. Sets N0, sets S37 to 6, and clears S31 bit 1. This command is equivalent to command string ATN0S37=6.
F6
Select V.32 bis 4800 or V.32 4800 as the only acceptable line modulation for a subsequent connection. Sets N0, sets S37 to 8, and clears S31 bit 1. This command is equivalent to command string ATN0S37=8.
F7
Selects V.32 bis 7200 as the only acceptable line modulation for a subsequent connection. Sets N0, sets S37 to 12, and clears S31 bit 1. This command is equivalent to command string ATN0S37=12. This setting also allows
1-6
Page 21
AT Command Set connection at the Rockwell proprietary 7200 V.32 speed, e.g., with a RC9696/ 12 based modem. F8
Selects V.32 bis 9600 or V.32 9600 as the only acceptable line modulations for a subsequent connection. Sets N0, sets S37 to 9, and clears S31 bit 1. This command is equivalent to command string ATN0S37=9.
F9
Selects V.32 bis 12000 as the only acceptable line modulation for a subsequent connection. Sets N0, sets S37 to 10, and clears S31 bit 1. This command is equivalent to command string ATN0S37=10. This setting also allows connection at the Rockwell proprietary 12000 V.32 speed, e.g., with a RC9696/12 based modem.
F10
Selects V.32 bis 14400 as the only acceptable line modulation for a subsequent connection. Sets N0, sets S37 to 11, and clears S31 bit 1. This command is equivalent to command string ATN0S37=11.
Hn, Disconnect (Hang-Up) Description Initiates a hang up sequence. H0
Releases the line if the modem is on-line, and terminates any test (AT&T) in progress. Country-specific, modulation-specific, and error correction protocolspecific (S38) processing is handled outside the H0 command.
H1
If on-hook, the modem goes off-hook and enters command mode. The modem returns on-hook after a period of time determined by S7.
Result Codes OK n = 0 or 1
ERROR Otherwise
1-7
Page 22
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Nn, Automode Enable Description Enables or disables automode detection. The parameter value, if valid, is written to S31 bit 1. N0
Disables automode detection (equivalent to setting the +MS <automode> subparameter to 0). A subsequent handshake is conducted according to the contents of S37 or, if S37 = 0, according to the most recently sensed DTE speed.
N1
Enables automode detection (equivalent to setting the +MS <automode> subparameter to 1). This command is also equivalent to Default.
Result Codes OK n = 0 or 1
ERROR Otherwise
Notes 1. The Nn and S37=x commands override the +MS command settings. When the N0 or N1 command is issued, the +MS subparameters are updated to reflect the Nn and S37 values (see +MS, Select Modulation on page 1-34 and S37, Desired Line Connection Speed on page 2-19). For example: N1S37=10 updates the +MS command subparameters to reflect +MS=10,1,300,12000 N0S37=10 updates the +MS command subparameters to reflect +MS=10,0,12000,12000 2. Tthe +MS command is recommended over the Nn and S37=x commands.
1-8
Page 23
AT Command Set
On, Return to On-Line Data Mode Description Determines how the modem enters the on-line data mode. In the on-line command mode, the modem enters the on-line data mode with or without a retrain. In the off-line command mode (no connection), ERROR is reported. O0
Enters on-line data mode without a retrain. Handling is determined by the Call Establishment task. If a connection exists, this command connects the DTE back to the remote modem after an escape (+++).
O1
Enters on-line data mode with a retrain before returning to on-line data mode.
Result Codes OK n = 0 or 1 and a connection exists
ERROR Otherwise or if not connected
P, Set Pulse Dial Default Description Forces pulse dialing until the next T dial modifier or T command is received. Sets S14 bit 5. A dial command that specifies the dialing mode for a particular call (e.g., ATDT) overrides this command so that all future dialing is tone dialled. (See T, Set Tone Dial Default on page 1-11.) Pulse dialing is not fitted on standard European model CRD1500-1100M-01.
Result Code OK
1-9
Page 24
CRD 1500 Modem/Charging Cradle Programmer’s Guide
Qn, Quiet Result Codes Control Description Enables or disables the sending of result codes to the DTE according to the parameter supplied. The parameter value, if valid, is written to S14 bit 2. Q0
Enables result codes to the DTE (default)
Q1
Disables result codes to the DTE
Result Codes OK n = 0 or 1
ERROR Otherwise
Sn, Read/Write S-Register Description Selects an S-Register, performs an S-Register read or write function, or reports the value of an S-Register. n
Establishes S-Register n as the last register accessed n=v
Sets S-Register n to the value v n?
Reports the value of S-Register n
Omit the parameter n to assume the last S-Register accessed. Omit the S for AT= and AT? to assume the last S-Register accessed. For example: ATS7 establishes S7 as the last accessed register. AT=40 sets the contents of the last register accessed to 40. ATS=20 sets the contents of the last register accessed to 20. If the number “n” is not in the range of available S-Registers, the modem returns the ERROR message. The value “v” is “MOD”ed with 256. If the result is outside the range permitted for a given S-Register the values are stored, but functionally the lower and higher limits are observed. Input and output are in decimal format. Note that some S-Registers are read-only.
1-10