Manual · Sick
Inductive sensor, IM 30 (SENSICK Catalogue)
Manual18 pagesPDF 1.2 MB
SENSICK catalog data sheets for the SICK IM 30 inductive proximity sensors (M30 x 1.5 housing): dimensions, wiring, technical data, order numbers.
What this file really is
The old site listed this file as a manual for the Sick IM30. Linked as a user manual, this is an excerpt of SICK's SENSICK catalog: data sheets for the IM 30 inductive sensor series, with no operating instructions.
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
Catalog pages from SICK's SENSICK catalog for the IM 30 inductive sensors in an M30 x 1.5 threaded housing. For each series (DC 3-wire Standard, Short version, Advanced flush and non-flush, Triplex, INOX, DC 2-wire, AC/DC 2-wire and NAMUR) it gives dimensional drawings, connection diagrams, technical data such as sensing range, supply voltage, switching frequency, enclosure rating and temperature, and order numbers for each type.
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Pages from the SICK SENSICK catalogue on IM 30 inductive proximity sensors with M30 threaded housings, rather than an operating manual. They cover the DC 3-wire Standard, Short, Advanced, Triplex and INOX series, the DC 2-wire and AC/DC 2-wire versions, and NAMUR sensors, each with a dimensional drawing, wiring, technical data and type list. The reader can compare sensing ranges, outputs, supply and connection types across the IM 30 range.
- What it is
- Inductive proximity sensors in a threaded M30 x 1.5 housing with display LED and two fastening nuts (width across 36) p. 1
- Series
- DC 3-wire Standard, Short version, Advanced, Triplex and INOX series; DC 2-wire and AC / DC 2-wire versions p. 1, 3, 5, 7, 9, 11, 13, 15
- Sensing range
- Standard, Short, DC 2-wire and AC / DC 2-wire: 10 / 15 mm; Advanced: 15 mm flush, 20 mm non-flush; Triplex: 22 / 40 mm; INOX: 20 / 40 mm p. 1, 3, 5, 7, 9, 11, 13, 15
- Supply voltage
- DC 3-wire and DC 2-wire: DC 10 ... 30 V; AC / DC 2-wire: AC / DC 20 ... 250 V; NAMUR: DC 5 ... 25 V p. 2, 14, 16, 18
- Connection
- Plug, M12, 4-pin or 2 m PVC cable; AC / DC 2-wire and NAMUR versions cable only p. 2, 16, 18
- Ambient temperature
- -25 °C ... +70 °C p. 2
- Enclosure rating
- IP 67; INOX series IP 69K p. 2, 12
- Standard series output
- Standard series: PNP or NPN, normally open or normally closed, continuous current ≤ 400 mA, max. 200 Hz p. 1, 2
- Short version
- Short version: continuous current ≤ 300 mA, max. 500 Hz, wire-break protection p. 3, 4
- Tightening torque
- Standard, Advanced, Triplex and DC 2-wire: 60 Nm; Short and AC / DC 2-wire: 50 Nm; INOX: 150 Nm p. 2, 4, 6, 8, 10, 12, 14, 16
- INOX series
- INOX series: one-piece stainless steel V4A, 316L housing, IP 69K, for the food and beverage sector p. 11, 12
- AC / DC 2-wire
- AC / DC 2-wire: continuous current ≤ 350 mA up to +50 °C, max. 25 Hz / 30 Hz (AC / DC) p. 15, 16
- NAMUR versions
- NAMUR to EN 60 947-5-6, rated DC 8.2 V; IM30-10B-N-ZW0 order no. 6 021 128, IM30-15N-N-ZW0 order no. 6 021 129 p. 17, 18
What this manual walks you through
- Dimensional drawings of each sensor series p. 1, 3, 5, 7, 9, 11, 13, 15
- Wiring and connection types for each series p. 1, 13, 15, 17
- Choosing a type from the order information p. 2, 4, 6, 8
- Mounting Triplex sensors quasi-flush in conductive material p. 10
- Correction factors for target materials (INOX series) p. 12
- Limits for connecting NAMUR sensors to an isolating amplifier p. 18
Good to know
- Triplex series: in conductive materials, mount with a distance A to the surface of 6 mm in steel or metal, 2 mm in stainless steel. p. 10
- AC / DC 2-wire versions: continuous current drops from 350 mA up to +50 °C to 250 mA up to +80 °C, and is 100 mA on DC. p. 16
- NAMUR versions: the isolating unit or amplifier may give at most 50 mA short-circuit current, 16 V no-load voltage and 75 mW. p. 18
Questions this manual answers
What supply voltage does the SICK IM30 inductive sensor need?
DC 3-wire and DC 2-wire types take DC 10 ... 30 V, AC / DC 2-wire types AC / DC 20 ... 250 V, and NAMUR types DC 5 ... 25 V. p. 2, 16, 18
What sensing range does the IM30 have?
It depends on the series: 10 / 15 mm for Standard types, up to 20 mm for Advanced, and 22 / 40 mm for Triplex. p. 1, 7, 9
What is the operating temperature of the IM30 sensors?
The catalogue gives an ambient temperature of -25 °C ... +70 °C. p. 2
Which IM30 sensor is rated IP 69K?
The INOX series, with a one-piece stainless steel V4A, 316L housing. p. 11, 12
What thread does the IM30 have?
An M30 x 1.5 fine thread, with two fastening nuts of width across 36. p. 1
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


