For the Sick IM30

Page 1

Inductive sensor, IM 30, DC 3-wire, Standard series

Sensing range 10 / 15 mm

Dimensional drawing 3 2

High switching frequency Short-circuit protection (pulsed)

M30x1.5

Inductive sensor

1

Robust brass housing, nickelplating with fine thread

50

60 3

M30 x 1.5 mm Enclosure rating IP 67

M30x1.5

2

1 38

12

60

M30x1.5

3 2

1 16

50

76

M30x1.5

3 2

1 16

38

12

76 1

Connection

2

Display LED

3

Fastening nuts (2 x); width across 36, metal

Connection type IM30-10BNS-ZW1 IM30-10BPS-ZW1 IM30-15NNS-ZW1 IM30-15NPS-ZW1 IM30-15NPO-ZW1

IM30-10BNS-ZC1 IM30-10BPS-ZC1 IM30-15NNS-ZC1 IM30-15NPS-ZC1

IM30-10BPO-ZC1

3 x 0.5 mm²

M12, 4-pin

M12, 4-pin

See chapter Accessories Connector, M12, 4-pin Mounting systems brn

L+ brn

1 blk

NO/NC blk

4 blu

M blu

262

SENSICK CATALOGUE

L+ brn

1

2 blk

2

3 blu

3

M

L+

4

NO

NC M

Page 2

IM 30 IM30-

Technical data

Sensing range Sn

10BNS 10BPS 10BNS 10BPO 10BPS 15NNS 15NPS 15NPO 15NNS 15NPS -ZW1 -ZW1 -ZC1 -ZC1 -ZC1 -ZW1 -ZW1 -ZW1 -ZC1 -ZC1

15 mm 10 mm

Electrical configuration

DC 3-wire

Supply voltage Vs

DC 10 ... 30 V

Ripple Vpp

≤ 10 %1)

Voltage drop Vd

≤ 1 V2)

Current consumption

≤ 20 mA3)

Continuous current Ia

≤ 400 mA

Time delay before availability tv

≤ 100 ms

Hysteresis H (of sr)

2 ... 10 %

Repeatability R

≤ 2 % (Ub and Ta constant)4)

Temperature drift, of sr

± 10 %

EMC

According to EN 60 947-5-2

Switching output

PNP NPN

Output function

Normally open Normally closed

Installation

Non-flush Flush

Connection types

Plug, M12, 4-pin Cable, PVC, 2 m

Enclosure rating

IP 675)

Max. switching frequency

200 Hz

Dimensions

M30 x 1.56)

Short-circuit protection

7)

Reverse polarity protection Power-up pulse suppression Shock / vibration stress

30 g, 11 ms / 10 ... 55 Hz, 1 mm

Ambient temperature Ta

-25 °C ... +70 °C

Housing material

Brass nickel-plated, plastic

Tightening material

60 Nm

1) of Ub 2)

3) without load 4)

at Ia max of sr

5) according to EN 60 529 6)

7)

(pulsed)

thread diameter x pitch (mm)

Order information Type IM30-10BNS-ZW1 IM30-10BPS-ZW1 IM30-10BNS-ZC1 IM30-10BPO-ZC1 IM30-10BPS-ZC1 IM30-15NNS-ZW1 IM30-15NPS-ZW1 IM30-15NPO-ZW1 IM30-15NNS-ZC1 IM30-15NPS-ZC1

Order no. 6 020 275 6 020 274 6 020 279 6 020 280 6 020 278 6 020 283 6 020 282 6 020 284 6 020 287 6 020 286

SENSICK CATALOGUE

263

Page 3

Inductive sensor, IM 30, DC 3-wire, Short version Dimensional drawing 3 2

Inductive sensor

Short-circuit protection (pulsed) Robust brass housing, nickel-

M30x1.5

Sensing range 10 / 15 mm

1 plating with fine thread M30 x 1.5 mm

40 3

Enclosure rating IP 67 High switching frequency

M30x1.5

2

1 25

40

M30x1.5

3 2

1 37

50

M30x1.5

3 2

1 22

15

50

See chapter Accessories Connector, M12, 4-pin Mounting systems

1

Connection

2

Display LED

3

Fastening nuts (2 x); width across 36, metal

Connection type IM30-10BNS-ZUK IM30-10BPS-ZUK IM30-15NPS-ZUK IM30-15NNS-ZUK

IM30-10BNS-ZCK IM30-10BPS-ZCK IM30-15NNS-ZCK IM30-15NPS-ZCK

3 x 0.5 mm²

M12, 4-pin brn

L+ brn

1 blk

NO blk

4 blu

M

SENSICK CATALOGUE

NO

2 blu

264

L+

3

M

Page 4

IM 30 IM30-

Technical data

Sensing range Sn

10BNS 10BPS 10BNS 10BPS 15NPS 15NNS 15NNS 15NPS -ZUK -ZUK -ZCK -ZCK -ZUK -ZUK -ZCK -ZCK

15 mm 10 mm

Electrical configuration

DC 3-wire

Supply voltage Vs

DC 10 ... 30 V

Ripple Vpp

≤ 10 %1)

Voltage drop Vd

≤ 1.5 V2)

Current consumption

≤ 10 mA3)

Continuous current Ia

≤ 300 mA

Time delay before availability tv

≤ 15 ms

Hysteresis H (of sr)

1 ... 10 %

Repeatability R

≤ 3 % (Ub and Ta constant)4)

Temperature drift, of sr

± 10 %

EMC

According to EN 60 947-5-2

Switching output

PNP NPN

Output function

Normally open

Installation

Non-flush Flush

Connection types

Plug, M12, 4-pin Cable, PVC/PUR, 2 m

Enclosure rating

IP 675)

Max. switching frequency

500 Hz

Dimensions

M30 x 1.56)

Wire-break protection Short-circuit protection

7)

Reverse polarity protection Power-up pulse suppression Shock / vibration stress

30 g, 11 ms / 10 ... 55 Hz, 1 mm

Ambient temperature Ta

-25 °C ... +70 °C

Housing material

Brass nickel-plated, plastic

Tightening material

50 Nm

1) of Ub 2)

3) without load 4)

at Ia max of sr

5) according to EN 60 529 6)

7)

(pulsed)

thread diameter x pitch (mm)

Order information Type IM30-10BNS-ZUK IM30-10BPS-ZUK IM30-10BNS-ZCK IM30-10BPS-ZCK IM30-15NPS-ZUK IM30-15NNS-ZUK IM30-15NNS-ZCK IM30-15NPS-ZCK

Order no. 1 017 446 1 017 434 1 017 448 1 017 436 1 017 435 1 017 447 1 017 449 1 017 437

SENSICK CATALOGUE

265

Page 5

Inductive sensor, IM 30, DC 3-wire, Advanced series, Flush Dimensional drawing

Inductive sensor

M30x1.5

3 2

Enhanced sensing range High switching frequency

1

Short-circuit protection (pulsed) Robust brass housing, nickel-

16

50

76 plated with fine thread M30 x 1.5 mm Enclosure rating IP 67

3 2

M30x1.5

Sensing range 15 mm

1 50

60

See chapter Accessories Connector, M12, 4-pin Mounting systems

1

Connection

2

Display LED

3

Fastening nuts (2 x); width across 36, metal

Connection type IM30-15BNS-ZW1 IM30-15BPO-ZW1 IM30-15BPS-ZW1

IM30-15BNS-ZC1 IM30-15BPS-ZC1

IM30-15BPO-ZC1

3 x 0.5 mm²

M12, 4-pin

M12, 4-pin brn

L+ blk

NO/NC blu

M brn

1 blk

4

SENSICK CATALOGUE

3 brn

M

1

L+

4

NO

2 blu

266

L+ blk

2 blu

3

NC M

Page 6

IM 30 IM30-

Technical data

Sensing range Sn

15 mm

Electrical configuration

DC 3-wire

Supply voltage Vs

DC 10 ... 30 V

Ripple Vpp

≤ 10 %1)

Voltage drop Vd

≤ 1 V2)

Current consumption

≤ 10 mA3)

Continuous current Ia

≤ 400 mA

Time delay before availability tv

≤ 100 ms

Hysteresis H (of sr)

2 ... 15 %

Repeatability R

≤ 5 % (Ub and Ta constant)4)

Temperature drift, of sr

± 10 %

EMC

According to EN 60 947-5-2

Switching output

PNP

15BNS 15BPO 15BPS 15BNS 15BPO 15BPS -ZW1 -ZW1 -ZW1 -ZC1 -ZC1 -ZC1

NPN Output function

Normally open Normally closed

Installation

Flush5)

Connection types

Plug, M12, 4-pin Cable, PVC, 2 m

Enclosure rating

IP 676)

Max. switching frequency

150 Hz

Dimensions

M30 x 1.57)

Short-circuit protection

8)

Reverse polarity protection Power-up pulse suppression Shock / vibration stress

30 g, 11 ms / 10 ... 55 Hz, 1 mm

Ambient temperature Ta

-25 °C ... +70 °C

Housing material

Brass nickel-plated, plastic

Tightening material

60 Nm

1) of Ub 2)

3) without load 4)

at Ia max of sr

5) see installation notes 6)

according to EN 60 529

7) thread diameter x pitch (mm) 8)

(pulsed)

Order information Type IM30-15BNS-ZW1 IM30-15BPO-ZW1 IM30-15BPS-ZW1 IM30-15BNS-ZC1 IM30-15BPO-ZC1 IM30-15BPS-ZC1

Order no. 7 900 142 7 900 143 7 900 141 7 900 146 7 900 147 7 900 145

SENSICK CATALOGUE

267

Page 7

Inductive sensor, IM 30, DC 3-wire, Advanced series, Non-flush

Sensing range 20 mm

Dimensional drawing 3 2

Enhanced sensing range High switching frequency

M30x1.5

Inductive sensor

1

Short-circuit protection (pulsed) Robust brass housing, nickel-

38

12

60 plated with fine thread M30 x 1.5 mm Enclosure rating IP 67

M30x1.5

3 2

1 16

38

12

76

1

Connection

2

Display LED

3

Fastening nuts (2 x); width across 36, metal

Connection type IM30-20NNS-ZW1 IM30-20NPO-ZW1 IM30-20NPS-ZW1

IM30-20NNS-ZC1 IM30-20NPS-ZC1

3 x 0.5 mm²

M12, 4-pin

See chapter Accessories Connector, M12, 4-pin Mounting systems brn

L+ brn

1 blk

NO/NC blk

4 blu

M

SENSICK CATALOGUE

NO

2 blu

268

L+

3

M

Page 8

IM 30 IM30-

Technical data

Sensing range Sn

20 mm

Electrical configuration

DC 3-wire

Supply voltage Vs

DC 10 ... 30 V

Ripple Vpp

≤ 10 %1)

Voltage drop Vd

≤ 1 V2)

Current consumption

≤ 10 mA3)

Continuous current Ia

≤ 400 mA

Time delay before availability tv

≤ 100 ms

Hysteresis H (of sr)

2 ... 15 %

Repeatability R

≤ 5 % (Ub and Ta constant)4)

Temperature drift, of sr

± 10 %

EMC

According to EN 60 947-5-2

Switching output

PNP

20NNS 20NPO 20NPS 20NNS 20NPS -ZW1 -ZW1 -ZW1 -ZC1 -ZC1

NPN Output function

Normally open Normally closed

Installation

Non-flush

Connection types

Plug, M12, 4-pin Cable, PVC, 2 m

Enclosure rating

IP 675)

Max. switching frequency

150 Hz

Dimensions

M30 x 1.56)

Short-circuit protection

7)

Reverse polarity protection Power-up pulse suppression Shock / vibration stress

30 g, 11 ms / 10 ... 55 Hz, 1 mm

Ambient temperature Ta

-25 °C ... +70 °C

Housing material

Brass nickel-plated, plastic

Tightening material

60 Nm

1) of Ub 2)

3) without load 4)

at Ia max of sr

5) according to EN 60 529 6)

7)

(pulsed)

thread diameter x pitch (mm)

Order information Type IM30-20NNS-ZW1 IM30-20NPO-ZW1 IM30-20NPS-ZW1 IM30-20NNS-ZC1 IM30-20NPS-ZC1

Order no. 7 900 154 7 900 155 7 900 153 7 900 158 7 900 157

SENSICK CATALOGUE

269

Page 9

Inductive sensor, IM 30, DC 3-wire, Triplex series

Sensing range 22 / 40 mm

Dimensional drawing 3 2

Triple sensing range Installation quasi flush or

M30x1.5

Inductive sensor

1 non-flush in metal Short-circuit protection (pulsed)

45

60

Robust brass housing, chromeplated with fine thread M30 x 1 mm

3

M30x1.5

2

Enclosure rating IP 67 1 8 12

11.5

45

73.5 10

3

M30x1.5

2

1 8 12

11.5

44

73.5

1

Connection

2

Display LED

3

Fastening nuts (2 x); width across 36, metal

Connection type IM30-22BNS-ZW1

See chapter Accessories Connector, M12, 4-pin Mounting systems

3 x 0.34 mm²

IM30-22BPS-ZC1 IM30-40NPS-ZC1

M12, 4-pin brn

L+ brn

1 blk

NO blk

4 blu

M

SENSICK CATALOGUE

NO

2 blu

270

L+

3