The text of a manual · part 1 of 2
Inductive sensor, IM 30 (SENSICK Catalogue), pages 1 to 9
Pages 1 to 9 of 18
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick IM30
Page 1
Inductive sensor, IM 30, DC 3-wire, Standard series
Sensing range 10 / 15 mm
Dimensional drawing 3 2
High switching frequency Short-circuit protection (pulsed)
M30x1.5
Inductive sensor
1
Robust brass housing, nickelplating with fine thread
50
60 3
M30 x 1.5 mm Enclosure rating IP 67
M30x1.5
2
1 38
12
60
M30x1.5
3 2
1 16
50
76
M30x1.5
3 2
1 16
38
12
76 1
Connection
2
Display LED
3
Fastening nuts (2 x); width across 36, metal
Connection type IM30-10BNS-ZW1 IM30-10BPS-ZW1 IM30-15NNS-ZW1 IM30-15NPS-ZW1 IM30-15NPO-ZW1
IM30-10BNS-ZC1 IM30-10BPS-ZC1 IM30-15NNS-ZC1 IM30-15NPS-ZC1
IM30-10BPO-ZC1
3 x 0.5 mm²
M12, 4-pin
M12, 4-pin
See chapter Accessories Connector, M12, 4-pin Mounting systems brn
L+ brn
1 blk
NO/NC blk
4 blu
M blu
262
SENSICK CATALOGUE
L+ brn
1
2 blk
2
3 blu
3
M
L+
4
NO
NC M
Page 2
IM 30 IM30-
Technical data
Sensing range Sn
10BNS 10BPS 10BNS 10BPO 10BPS 15NNS 15NPS 15NPO 15NNS 15NPS -ZW1 -ZW1 -ZC1 -ZC1 -ZC1 -ZW1 -ZW1 -ZW1 -ZC1 -ZC1
15 mm 10 mm
Electrical configuration
DC 3-wire
Supply voltage Vs
DC 10 ... 30 V
Ripple Vpp
≤ 10 %1)
Voltage drop Vd
≤ 1 V2)
Current consumption
≤ 20 mA3)
Continuous current Ia
≤ 400 mA
Time delay before availability tv
≤ 100 ms
Hysteresis H (of sr)
2 ... 10 %
Repeatability R
≤ 2 % (Ub and Ta constant)4)
Temperature drift, of sr
± 10 %
EMC
According to EN 60 947-5-2
Switching output
PNP NPN
Output function
Normally open Normally closed
Installation
Non-flush Flush
Connection types
Plug, M12, 4-pin Cable, PVC, 2 m
Enclosure rating
IP 675)
Max. switching frequency
200 Hz
Dimensions
M30 x 1.56)
Short-circuit protection
7)
Reverse polarity protection Power-up pulse suppression Shock / vibration stress
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient temperature Ta
-25 °C ... +70 °C
Housing material
Brass nickel-plated, plastic
Tightening material
60 Nm
1) of Ub 2)
3) without load 4)
at Ia max of sr
5) according to EN 60 529 6)
7)
(pulsed)
thread diameter x pitch (mm)
Order information Type IM30-10BNS-ZW1 IM30-10BPS-ZW1 IM30-10BNS-ZC1 IM30-10BPO-ZC1 IM30-10BPS-ZC1 IM30-15NNS-ZW1 IM30-15NPS-ZW1 IM30-15NPO-ZW1 IM30-15NNS-ZC1 IM30-15NPS-ZC1
Order no. 6 020 275 6 020 274 6 020 279 6 020 280 6 020 278 6 020 283 6 020 282 6 020 284 6 020 287 6 020 286
SENSICK CATALOGUE
263
Page 3
Inductive sensor, IM 30, DC 3-wire, Short version Dimensional drawing 3 2
Inductive sensor
Short-circuit protection (pulsed) Robust brass housing, nickel-
M30x1.5
Sensing range 10 / 15 mm
1 plating with fine thread M30 x 1.5 mm
40 3
Enclosure rating IP 67 High switching frequency
M30x1.5
2
1 25
40
M30x1.5
3 2
1 37
50
M30x1.5
3 2
1 22
15
50
See chapter Accessories Connector, M12, 4-pin Mounting systems
1
Connection
2
Display LED
3
Fastening nuts (2 x); width across 36, metal
Connection type IM30-10BNS-ZUK IM30-10BPS-ZUK IM30-15NPS-ZUK IM30-15NNS-ZUK
IM30-10BNS-ZCK IM30-10BPS-ZCK IM30-15NNS-ZCK IM30-15NPS-ZCK
3 x 0.5 mm²
M12, 4-pin brn
L+ brn
1 blk
NO blk
4 blu
M
SENSICK CATALOGUE
NO
2 blu
264
L+
3
M
Page 4
IM 30 IM30-
Technical data
Sensing range Sn
10BNS 10BPS 10BNS 10BPS 15NPS 15NNS 15NNS 15NPS -ZUK -ZUK -ZCK -ZCK -ZUK -ZUK -ZCK -ZCK
15 mm 10 mm
Electrical configuration
DC 3-wire
Supply voltage Vs
DC 10 ... 30 V
Ripple Vpp
≤ 10 %1)
Voltage drop Vd
≤ 1.5 V2)
Current consumption
≤ 10 mA3)
Continuous current Ia
≤ 300 mA
Time delay before availability tv
≤ 15 ms
Hysteresis H (of sr)
1 ... 10 %
Repeatability R
≤ 3 % (Ub and Ta constant)4)
Temperature drift, of sr
± 10 %
EMC
According to EN 60 947-5-2
Switching output
PNP NPN
Output function
Normally open
Installation
Non-flush Flush
Connection types
Plug, M12, 4-pin Cable, PVC/PUR, 2 m
Enclosure rating
IP 675)
Max. switching frequency
500 Hz
Dimensions
M30 x 1.56)
Wire-break protection Short-circuit protection
7)
Reverse polarity protection Power-up pulse suppression Shock / vibration stress
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient temperature Ta
-25 °C ... +70 °C
Housing material
Brass nickel-plated, plastic
Tightening material
50 Nm
1) of Ub 2)
3) without load 4)
at Ia max of sr
5) according to EN 60 529 6)
7)
(pulsed)
thread diameter x pitch (mm)
Order information Type IM30-10BNS-ZUK IM30-10BPS-ZUK IM30-10BNS-ZCK IM30-10BPS-ZCK IM30-15NPS-ZUK IM30-15NNS-ZUK IM30-15NNS-ZCK IM30-15NPS-ZCK
Order no. 1 017 446 1 017 434 1 017 448 1 017 436 1 017 435 1 017 447 1 017 449 1 017 437
SENSICK CATALOGUE
265
Page 5
Inductive sensor, IM 30, DC 3-wire, Advanced series, Flush Dimensional drawing
Inductive sensor
M30x1.5
3 2
Enhanced sensing range High switching frequency
1
Short-circuit protection (pulsed) Robust brass housing, nickel-
16
50
76 plated with fine thread M30 x 1.5 mm Enclosure rating IP 67
3 2
M30x1.5
Sensing range 15 mm
1 50
60
See chapter Accessories Connector, M12, 4-pin Mounting systems
1
Connection
2
Display LED
3
Fastening nuts (2 x); width across 36, metal
Connection type IM30-15BNS-ZW1 IM30-15BPO-ZW1 IM30-15BPS-ZW1
IM30-15BNS-ZC1 IM30-15BPS-ZC1
IM30-15BPO-ZC1
3 x 0.5 mm²
M12, 4-pin
M12, 4-pin brn
L+ blk
NO/NC blu
M brn
1 blk
4
SENSICK CATALOGUE
3 brn
M
1
L+
4
NO
2 blu
266
L+ blk
2 blu
3
NC M
Page 6
IM 30 IM30-
Technical data
Sensing range Sn
15 mm
Electrical configuration
DC 3-wire
Supply voltage Vs
DC 10 ... 30 V
Ripple Vpp
≤ 10 %1)
Voltage drop Vd
≤ 1 V2)
Current consumption
≤ 10 mA3)
Continuous current Ia
≤ 400 mA
Time delay before availability tv
≤ 100 ms
Hysteresis H (of sr)
2 ... 15 %
Repeatability R
≤ 5 % (Ub and Ta constant)4)
Temperature drift, of sr
± 10 %
EMC
According to EN 60 947-5-2
Switching output
PNP
15BNS 15BPO 15BPS 15BNS 15BPO 15BPS -ZW1 -ZW1 -ZW1 -ZC1 -ZC1 -ZC1
NPN Output function
Normally open Normally closed
Installation
Flush5)
Connection types
Plug, M12, 4-pin Cable, PVC, 2 m
Enclosure rating
IP 676)
Max. switching frequency
150 Hz
Dimensions
M30 x 1.57)
Short-circuit protection
8)
Reverse polarity protection Power-up pulse suppression Shock / vibration stress
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient temperature Ta
-25 °C ... +70 °C
Housing material
Brass nickel-plated, plastic
Tightening material
60 Nm
1) of Ub 2)
3) without load 4)
at Ia max of sr
5) see installation notes 6)
according to EN 60 529
7) thread diameter x pitch (mm) 8)
(pulsed)
Order information Type IM30-15BNS-ZW1 IM30-15BPO-ZW1 IM30-15BPS-ZW1 IM30-15BNS-ZC1 IM30-15BPO-ZC1 IM30-15BPS-ZC1
Order no. 7 900 142 7 900 143 7 900 141 7 900 146 7 900 147 7 900 145
SENSICK CATALOGUE
267
Page 7
Inductive sensor, IM 30, DC 3-wire, Advanced series, Non-flush
Sensing range 20 mm
Dimensional drawing 3 2
Enhanced sensing range High switching frequency
M30x1.5
Inductive sensor
1
Short-circuit protection (pulsed) Robust brass housing, nickel-
38
12
60 plated with fine thread M30 x 1.5 mm Enclosure rating IP 67
M30x1.5
3 2
1 16
38
12
76
1
Connection
2
Display LED
3
Fastening nuts (2 x); width across 36, metal
Connection type IM30-20NNS-ZW1 IM30-20NPO-ZW1 IM30-20NPS-ZW1
IM30-20NNS-ZC1 IM30-20NPS-ZC1
3 x 0.5 mm²
M12, 4-pin
See chapter Accessories Connector, M12, 4-pin Mounting systems brn
L+ brn
1 blk
NO/NC blk
4 blu
M
SENSICK CATALOGUE
NO
2 blu
268
L+
3
M
Page 8
IM 30 IM30-
Technical data
Sensing range Sn
20 mm
Electrical configuration
DC 3-wire
Supply voltage Vs
DC 10 ... 30 V
Ripple Vpp
≤ 10 %1)
Voltage drop Vd
≤ 1 V2)
Current consumption
≤ 10 mA3)
Continuous current Ia
≤ 400 mA
Time delay before availability tv
≤ 100 ms
Hysteresis H (of sr)
2 ... 15 %
Repeatability R
≤ 5 % (Ub and Ta constant)4)
Temperature drift, of sr
± 10 %
EMC
According to EN 60 947-5-2
Switching output
PNP
20NNS 20NPO 20NPS 20NNS 20NPS -ZW1 -ZW1 -ZW1 -ZC1 -ZC1
NPN Output function
Normally open Normally closed
Installation
Non-flush
Connection types
Plug, M12, 4-pin Cable, PVC, 2 m
Enclosure rating
IP 675)
Max. switching frequency
150 Hz
Dimensions
M30 x 1.56)
Short-circuit protection
7)
Reverse polarity protection Power-up pulse suppression Shock / vibration stress
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient temperature Ta
-25 °C ... +70 °C
Housing material
Brass nickel-plated, plastic
Tightening material
60 Nm
1) of Ub 2)
3) without load 4)
at Ia max of sr
5) according to EN 60 529 6)
7)
(pulsed)
thread diameter x pitch (mm)
Order information Type IM30-20NNS-ZW1 IM30-20NPO-ZW1 IM30-20NPS-ZW1 IM30-20NNS-ZC1 IM30-20NPS-ZC1
Order no. 7 900 154 7 900 155 7 900 153 7 900 158 7 900 157
SENSICK CATALOGUE
269
Page 9
Inductive sensor, IM 30, DC 3-wire, Triplex series
Sensing range 22 / 40 mm
Dimensional drawing 3 2
Triple sensing range Installation quasi flush or
M30x1.5
Inductive sensor
1 non-flush in metal Short-circuit protection (pulsed)
45
60
Robust brass housing, chromeplated with fine thread M30 x 1 mm
3
M30x1.5
2
Enclosure rating IP 67 1 8 12
11.5
45
73.5 10
3
M30x1.5
2
1 8 12
11.5
44
73.5
1
Connection
2
Display LED
3
Fastening nuts (2 x); width across 36, metal
Connection type IM30-22BNS-ZW1
See chapter Accessories Connector, M12, 4-pin Mounting systems
3 x 0.34 mm²
IM30-22BPS-ZC1 IM30-40NPS-ZC1
M12, 4-pin brn
L+ brn
1 blk
NO blk
4 blu
M
SENSICK CATALOGUE
NO
2 blu
270
L+
3
M