For the Sick CLV503 and Sick CLV505

Page 9

Readable code types and test codes

CLV503

CLV505

ICR803

Description

Chinese Post

●

●

●

Codabar

●

●

●

●

●

1D codes, linear

Codablock Code 11

Code 128

●

Code 32 PARAF

●

Code 39

●

●

●

Code 93

●

●

●

Code 128

●

●

●

GS1 Databar-14

●

●

●

GS1 Databar Expanded

●

●

●

GS1 Databar Limited

●

●

●

GS1 Databar Truncated

●

●

●

IATA

●

●

●

Industrial 2 of 5

●

●

●

Interleaved 2 of 5

●

●

●

ISBN-ISMN-ISSN

●

●

●

JAN/UPC/EAN

●

●

●

Korean Postal Authority code

●

●

●

Matrix 2 of 5

●

●

●

MSI-Plessey/UK-Plessey

●

●

●

S-Code

●

●

Telepen

●

●

Tri-Optic

●

●

GS1 Databar-14 Stacked

●

●

●

GS1 Databar Expanded Stacked

●

●

●

GS1 Databar Stacked

●

●

●

GS1 Databar with Composite A/B

●

●

MicroPDF417

●

●

●

PDF417

●

●

●

Posicode

Interleaved 2 of 5

EAN 13

● ●

PDF417

1D codes, stacked

Data Matrix

2D codes Aztec

●

Data Matrix

●

Maxicode

●

QR-Code

●

OCR OCR-A, OCR-B

●

Image capture BMP, JPEG, TIFF

2009-04

QR-Code

●

S ic k

|

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3

9

Page 10

Dimensional drawings and reading field diagrams CLV503 / CLV505 Dimensional drawing CLV503 43.3 10 20

34.5

ø 1.5; 1 deep

M3; 4 deep

7.3

6.3

20 43

27

30

1°

5 17

7

M2; 3.5 deep

2°

ø 2; 3.5 deep

Dimensional drawing CLV505

24.5

20 10.5

ø 2; 3.5 deep

19.7 12.6

8.4

M2; 3.5 deep

42° 70° 40° 13

10

0001

4.5 13.5 7 29

64° 54° 44°

M3; 5 deep

ø 1.5; 1 deep Dimensions in mm

Reading field diagram CLV503 320

Reading field diagram CLV505

Reading field height (mm)

Reading field height (mm) 200

240

150

Resolution

160 80

50

0.15 mm

0

10

0.25 mm 1.0 mm

-80

0.5 mm

-240

-150

100

200

300

0.25 mm 0.5 mm 1.0 mm

-50 -100

0

0.15 mm

0

-160

-320

Resolution

100

400

500 600 700 800 Reading distance (mm)

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k

-200

0

100

200

300 400 Reading distance (mm) 2009-04

Page 11

Dimensional drawings and reading field diagrams ICR803 Dimensional drawing ICR803

12.2

22.9

21.8

47.8

45

M3; 6.3 deep

39.9

24.1

14

Dimensions in mm

Reading field diagram ICR803-A

Reading field diagram ICR803-B

Module/Cell size (mm)

Module/Cell size (mm)

0.19

0.33

0.21 50

2009-04

100

0.38 150

200

250 300 350 Reading distance (mm)

50

100

150

S ic k

200

|

250 300 350 Reading distance (mm)

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3

11

Page 12

Ordering information devices and power supply CLV503 Order no.

Type

Description

1046315

CLV503-0000

Line scanner, front reading window, cable with open wire ends, RS 232 data interface

1046316

CLV503-0110

Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface

Order no.

Type

Description

1046317

CLV505-0000

Line scanner, front reading window, cable with open wire ends, RS 232 data interface

1046318

CLV505-0110

Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface

1046319

CLV505-1000

Grid scanner, front reading window, cable with open wire ends, RS 232 data interface

1046320

CLV505-1110

Grid scanner, front reading window, cable with USB plug, USB VCP/HID data interface

Type

Description

6034210

ICR803-A0201

2D Image Code Reader ICR803-A0201, optical version A, RS 232 data interface

6034212

ICR803-A0271

2D Image Code Reader ICR803-A0201, optical version A, USB data interface

6034211

ICR803-B0201

2D Image Code Reader ICR803-A0201, optical version B, RS 232 data interface

6034213

ICR803-B0271

2D Image Code Reader ICR803-A0201, optical version B, USB data interface

CLV505

ICR803 Order no. Geräte

Power supply, power supply cables

12

6034941

PS5U-42E

5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with European safety plug

●

6034942

PS5U-43E

5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with UK plug

●

6034790

PS5U-41E

5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with USA plug

●

6034354

Power supply cable with flat European plug

●

6034357

Power supply cable with Australian plug

●

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k

ICR803

Description

CLV505

Type

CLV503

Order no.

2009-04

Page 13

Accessories Cables and connectors

6028232

2.4 m

Straight USB cable

●

6033047

2.4 m

Straight RS 232 TTL cable, 2.4 m length, external power supply (see page 12) necessary

●

6028186

2.4 m

Straight RS 232 TTL cable, 2.4 m length, power supply on pin 9

●

Connection module CDB405-001 with integrated 24/5 V DC converter

●

1027093

ICR803

Description

CLV505

Length

CLV503

Order no.

Straight RS 232 TTL cable, 2 m length, for connection of ICR803 to CDB405-001

●

6032516

2.8 m

USB spiral cable

●

6012109

2.4 m

RS 232 TTL spiral cable, external power supply device necessary (see page 12)

●

6025955

2.4 m

RS 232 TTL spiral cable, power supply on pin 9

●

D-Sub plug-in connector insert, 15-pin HD receptacle strip (socket), manual solder connection

●

●

6010020

D-Sub plug-in connector insert, 15-pin HD receptacle strip (plug), manual solder connection

●

●

6009438

D-Sub plug-in connector housing (metal) for 9-pin/15-pin HD inserts

●

●

CLV505

2m

CLV503

6034935

6010019

Order no.

Description

2050021

Mounting bracket for CLV503

ICR803

Brackets

● 2050022

Mounting bracket for CLV505 ●

2050023

Mounting bracket for ICR803 ●

2009-04

S ic k

|

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3

13

Page 14

Configuration Parameterisation of Mini Line devices takes place via configuration bar codes. Via configuration bar codes

It really is this easy:

Starting from the basic default settings, it is easy to change the most important parameter values to adapt to the application with the help of the configuration bar codes provided (see Quick Start for the particular product).

• Go to the graphic user interface at http://setup-mini-line.sick.com • Select the bar code for the desired configuration and print it out • Scan the configuration bar code

An online tool is available at http://setup-mini-line.sick.com for the expanded configuration. This tool also provides the configuration in the form of configuration bar codes.

14

M I n I L I n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S I C k

2009-04

Page 15

SICK Service for optimized Auto Ident solutions

Pre-Sales

Installation phase

Application consulting

Installation and commissioning

• Examination of economic practicality • Assessment of cost-determining parameters • SICK engineering teams propose best possible individual solution

• SICK service technicians carry out installation worldwide • SICK engineers carry out commissioning • Optimum configuration

Engineering

Site management

• Intelligent solutions resulting from combination of individual systems • SICK Quality Management System ensures the high dependability of customer systems

• Smooth project progress through co-ordination of work on site

Project management

• SICK Service Specialists confirm the agreed performance features during a trial phase under practical conditions

• SICK project management teams ensure optimum project progress from the planning phase to acceptance

Acceptance

After-Sales Maintenance

Hotline

SICK scanners and RFID systems are maintenance-free. Regular cleaning and adjustment work is, however, recommended to ensure optimum performance during the whole operating period, e.g. • to detect changes in the application • to repair any damage

• SICK sales organisations can be contacted via a free technical Hotline • Questions receive rapid answers or are forwarded to the relevant specialist departments without delay

Troubleshooting and spare parts

• Comprehensive training program at SICK or on site • Tailor-made, product-specific courses for project planners, commissioning technicians and maintenance staff • Participants receive support in the achievement of their particular tasks within the works

• Co-ordinated spare part and repair concept • Development of economically interesting models • Such models and other services agreed in service contracts

Training

SICK supports you during every phase of your Auto Ident projects – for technically and economically optimum solutions. 2009-04

S ic k

|

M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3

15

Page 16

8012891/2009-04 ∙ SS Subject to change without notice ∙ 00 WB USmod int32

OU R C o mp e t e n c e i n t h e b u si n e ss s e gm e n t s

F a c t o ry a u t o m at i o n

L o gis t ics a u t o m at i o n

P r o c e ss a u t o m at i o n

With its intelligent sensors, safety systems, and auto ident applications, SICK realises comprehensive solutions for factory automation.

Sensors made by SICK form the basis for automating material flows and the optimisation of sorting and warehousing processes.

Analyzers and Process Instrumentation by SICK MAIHAK provides for the best possible acquisition of environmental and process data.

• Non-contact detecting, counting,

• Automated identification with bar

• Complete systems solutions for gas classifying, and positioning of any types of object • Accident protection and personal safety using sensors, as well as safety software and services code and RFID reading devices for the purpose of sorting and target control in industrial material flow • Detecting volume, position, and contours of objects and surroundings with laser measurement systems

Worldwide presence with subsidiaries in the following countries:

Nederlands

Australia Belgium/Luxembourg Brasil Ceská Republika China Danmark Deutschland España France Great Britain India Israel

Norge Österreich Polska analysis, dust measurement, flow rate measurement, water analysis or, respectively, liquid analysis, and level measurement as well as other tasks

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com

Republic of Korea Republika Slovenija România Russia Schweiz Singapore Suomi Sverige Taiwan Türkiye USA/Canada/México

Italia Japan

SICK AG | Waldkirch | Germany | www.sick.com

Handed over by: