Page 9
Readable code types and test codes
CLV503
CLV505
ICR803
Description
Chinese Post
●
●
●
Codabar
●
●
●
●
●
1D codes, linear
Codablock Code 11
Code 128
●
Code 32 PARAF
●
Code 39
●
●
●
Code 93
●
●
●
Code 128
●
●
●
GS1 Databar-14
●
●
●
GS1 Databar Expanded
●
●
●
GS1 Databar Limited
●
●
●
GS1 Databar Truncated
●
●
●
IATA
●
●
●
Industrial 2 of 5
●
●
●
Interleaved 2 of 5
●
●
●
ISBN-ISMN-ISSN
●
●
●
JAN/UPC/EAN
●
●
●
Korean Postal Authority code
●
●
●
Matrix 2 of 5
●
●
●
MSI-Plessey/UK-Plessey
●
●
●
S-Code
●
●
Telepen
●
●
Tri-Optic
●
●
GS1 Databar-14 Stacked
●
●
●
GS1 Databar Expanded Stacked
●
●
●
GS1 Databar Stacked
●
●
●
GS1 Databar with Composite A/B
●
●
MicroPDF417
●
●
●
PDF417
●
●
●
Posicode
Interleaved 2 of 5
EAN 13
● ●
PDF417
1D codes, stacked
Data Matrix
2D codes Aztec
●
Data Matrix
●
Maxicode
●
QR-Code
●
OCR OCR-A, OCR-B
●
Image capture BMP, JPEG, TIFF
2009-04
QR-Code
●
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
9
Page 10
Dimensional drawings and reading field diagrams CLV503 / CLV505 Dimensional drawing CLV503 43.3 10 20
34.5
ø 1.5; 1 deep
M3; 4 deep
7.3
6.3
20 43
27
30
1°
5 17
7
M2; 3.5 deep
2°
ø 2; 3.5 deep
Dimensional drawing CLV505
24.5
20 10.5
ø 2; 3.5 deep
19.7 12.6
8.4
M2; 3.5 deep
42° 70° 40° 13
10
0001
4.5 13.5 7 29
64° 54° 44°
M3; 5 deep
ø 1.5; 1 deep Dimensions in mm
Reading field diagram CLV503 320
Reading field diagram CLV505
Reading field height (mm)
Reading field height (mm) 200
240
150
Resolution
160 80
50
0.15 mm
0
10
0.25 mm 1.0 mm
-80
0.5 mm
-240
-150
100
200
300
0.25 mm 0.5 mm 1.0 mm
-50 -100
0
0.15 mm
0
-160
-320
Resolution
100
400
500 600 700 800 Reading distance (mm)
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
-200
0
100
200
300 400 Reading distance (mm) 2009-04
Page 11
Dimensional drawings and reading field diagrams ICR803 Dimensional drawing ICR803
12.2
22.9
21.8
47.8
45
M3; 6.3 deep
39.9
24.1
14
Dimensions in mm
Reading field diagram ICR803-A
Reading field diagram ICR803-B
Module/Cell size (mm)
Module/Cell size (mm)
0.19
0.33
0.21 50
2009-04
100
0.38 150
200
250 300 350 Reading distance (mm)
50
100
150
S ic k
200
|
250 300 350 Reading distance (mm)
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
11
Page 12
Ordering information devices and power supply CLV503 Order no.
Type
Description
1046315
CLV503-0000
Line scanner, front reading window, cable with open wire ends, RS 232 data interface
1046316
CLV503-0110
Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface
Order no.
Type
Description
1046317
CLV505-0000
Line scanner, front reading window, cable with open wire ends, RS 232 data interface
1046318
CLV505-0110
Line scanner, front reading window, cable with USB plug, USB VCP/HID data interface
1046319
CLV505-1000
Grid scanner, front reading window, cable with open wire ends, RS 232 data interface
1046320
CLV505-1110
Grid scanner, front reading window, cable with USB plug, USB VCP/HID data interface
Type
Description
6034210
ICR803-A0201
2D Image Code Reader ICR803-A0201, optical version A, RS 232 data interface
6034212
ICR803-A0271
2D Image Code Reader ICR803-A0201, optical version A, USB data interface
6034211
ICR803-B0201
2D Image Code Reader ICR803-A0201, optical version B, RS 232 data interface
6034213
ICR803-B0271
2D Image Code Reader ICR803-A0201, optical version B, USB data interface
CLV505
ICR803 Order no. Geräte
Power supply, power supply cables
12
6034941
PS5U-42E
5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with European safety plug
●
6034942
PS5U-43E
5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with UK plug
●
6034790
PS5U-41E
5 V DC, input voltage 100 to 240 V at 47 to 63 Hz, incl. power supply cable with USA plug
●
6034354
Power supply cable with flat European plug
●
6034357
Power supply cable with Australian plug
●
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
ICR803
Description
CLV505
Type
CLV503
Order no.
2009-04
Page 13
Accessories Cables and connectors
6028232
2.4 m
Straight USB cable
●
6033047
2.4 m
Straight RS 232 TTL cable, 2.4 m length, external power supply (see page 12) necessary
●
6028186
2.4 m
Straight RS 232 TTL cable, 2.4 m length, power supply on pin 9
●
Connection module CDB405-001 with integrated 24/5 V DC converter
●
1027093
ICR803
Description
CLV505
Length
CLV503
Order no.
Straight RS 232 TTL cable, 2 m length, for connection of ICR803 to CDB405-001
●
6032516
2.8 m
USB spiral cable
●
6012109
2.4 m
RS 232 TTL spiral cable, external power supply device necessary (see page 12)
●
6025955
2.4 m
RS 232 TTL spiral cable, power supply on pin 9
●
D-Sub plug-in connector insert, 15-pin HD receptacle strip (socket), manual solder connection
●
●
6010020
D-Sub plug-in connector insert, 15-pin HD receptacle strip (plug), manual solder connection
●
●
6009438
D-Sub plug-in connector housing (metal) for 9-pin/15-pin HD inserts
●
●
CLV505
2m
CLV503
6034935
6010019
Order no.
Description
2050021
Mounting bracket for CLV503
ICR803
Brackets
● 2050022
Mounting bracket for CLV505 ●
2050023
Mounting bracket for ICR803 ●
2009-04
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
13
Page 14
Configuration Parameterisation of Mini Line devices takes place via configuration bar codes. Via configuration bar codes
It really is this easy:
Starting from the basic default settings, it is easy to change the most important parameter values to adapt to the application with the help of the configuration bar codes provided (see Quick Start for the particular product).
• Go to the graphic user interface at http://setup-mini-line.sick.com • Select the bar code for the desired configuration and print it out • Scan the configuration bar code
An online tool is available at http://setup-mini-line.sick.com for the expanded configuration. This tool also provides the configuration in the form of configuration bar codes.
14
M I n I L I n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S I C k
2009-04
Page 15
SICK Service for optimized Auto Ident solutions
Pre-Sales
Installation phase
Application consulting
Installation and commissioning
• Examination of economic practicality • Assessment of cost-determining parameters • SICK engineering teams propose best possible individual solution
• SICK service technicians carry out installation worldwide • SICK engineers carry out commissioning • Optimum configuration
Engineering
Site management
• Intelligent solutions resulting from combination of individual systems • SICK Quality Management System ensures the high dependability of customer systems
• Smooth project progress through co-ordination of work on site
Project management
• SICK Service Specialists confirm the agreed performance features during a trial phase under practical conditions
• SICK project management teams ensure optimum project progress from the planning phase to acceptance
Acceptance
After-Sales Maintenance
Hotline
SICK scanners and RFID systems are maintenance-free. Regular cleaning and adjustment work is, however, recommended to ensure optimum performance during the whole operating period, e.g. • to detect changes in the application • to repair any damage
• SICK sales organisations can be contacted via a free technical Hotline • Questions receive rapid answers or are forwarded to the relevant specialist departments without delay
Troubleshooting and spare parts
• Comprehensive training program at SICK or on site • Tailor-made, product-specific courses for project planners, commissioning technicians and maintenance staff • Participants receive support in the achievement of their particular tasks within the works
• Co-ordinated spare part and repair concept • Development of economically interesting models • Such models and other services agreed in service contracts
Training
SICK supports you during every phase of your Auto Ident projects – for technically and economically optimum solutions. 2009-04
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
15
Page 16
8012891/2009-04 ∙ SS Subject to change without notice ∙ 00 WB USmod int32
OU R C o mp e t e n c e i n t h e b u si n e ss s e gm e n t s
F a c t o ry a u t o m at i o n
L o gis t ics a u t o m at i o n
P r o c e ss a u t o m at i o n
With its intelligent sensors, safety systems, and auto ident applications, SICK realises comprehensive solutions for factory automation.
Sensors made by SICK form the basis for automating material flows and the optimisation of sorting and warehousing processes.
Analyzers and Process Instrumentation by SICK MAIHAK provides for the best possible acquisition of environmental and process data.
• Non-contact detecting, counting,
• Automated identification with bar
• Complete systems solutions for gas classifying, and positioning of any types of object • Accident protection and personal safety using sensors, as well as safety software and services code and RFID reading devices for the purpose of sorting and target control in industrial material flow • Detecting volume, position, and contours of objects and surroundings with laser measurement systems
Worldwide presence with subsidiaries in the following countries:
Nederlands
Australia Belgium/Luxembourg Brasil Ceská Republika China Danmark Deutschland España France Great Britain India Israel
Norge Österreich Polska analysis, dust measurement, flow rate measurement, water analysis or, respectively, liquid analysis, and level measurement as well as other tasks
Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com
Republic of Korea Republika Slovenija România Russia Schweiz Singapore Suomi Sverige Taiwan Türkiye USA/Canada/México
Italia Japan
SICK AG | Waldkirch | Germany | www.sick.com
Handed over by: