The text of a spec sheet · part 1 of 2
Small, simple, reliable: the Mini Line CLV503 / CLV505 / ICR803, pages 1 to 8
Pages 1 to 8 of 16
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV503 and Sick CLV505
Page 1
P r o d u C t i n f o rm at i o n
Small, simple, reliable – the Mini Line CLV503 / CLV505 / ICR803
The small giants amongst stationary bar code scanners
Page 2
The Mini Line: CLV503, CLV505, ICR803
Contents
2
The Mini Line: CLV503, CLV505, ICR803
2
Typical industries and applications
4
The devices of the Mini Line
5
Device features
6
Product selection guide
7
Technical data
8
Readable code types and test codes
9
Dimensional drawings and reading field diagrams CLV503 / CLV505
10
Dimensional drawings and reading field diagrams ICR803
11
Ordering information devices and power supply
12
Accessories
13
Configuration
14
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
2009-04
Page 3
Every millimetre counts when space is limited. Nevertheless, it is essential that the codes are reliably identified – and SICK offers products with its familiar dependability. Mini Line devices are hardly bigger than a USB plug and are easy to install in the tightest of spaces. Impressive qualities: small, easy and reliable – the Mini Line.
2009-04
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
3
Page 4
Typical industries and applications The devices of the Mini Line are ideal when the need for reliable code reading is high but the space available is limited. Kiosk • Access control, e.g. −− Car parks −− Airports −− Ticket terminals −− Swimming pools/trade fairs/ events • Information terminals • Vending /recycling machines • Automatic lottery machines
Car park entrance
Ticket machine
Access control at trade fair
Access control at station
Bar codes on test tubes
Data Matrix codes on circuit boards
Robotics
Mounted on robot arms
Pharmaceuticals • Clinical analyses Electronics industry • Circuit board identification Automotive • Inspection machines Robotics • Mounted on robot arms, e.g. in data storage centres
Your benefits: • Small size • Low weight • Reliable reading even with poorly printed codes • Simple commissioning
4
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
2009-04
Page 5
The devices of the Mini Line
CLV503 / CLV505 1D
CLV503 and CLV505 devices use laser technology (line or grid scanners).
Stacked
They scan the barcode to be identified for light and dark bars. The reflected light is received by the laser scanner, whereby the light from the black bars is weaker than that from the white spaces. The signal received is digitized and then decoded.
Allocation of the scanning line(s) for the bar code and conveyor system
ICR803 1D
Stacked
2D
OCR Best before 2009-04-30
ICR803 devices use camera technology. They record an image of the object and search through this with image processing algorithms for 1D or 2D codes, which are then decoded. The codes can be identified with one device and omni-directionally (360°). Image processing also permits the identification of OCR-A and OCR-B fonts.
360°
Omnidirectional code reading
2009-04
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
5
Page 6
Device features
Aligned
Omnidirectional
Code reading While the target codes must be aligned for the CLV503/CKV505, the ICR803 reads omnidirectionally, i.e. in any orientation.
USB
RS 232 D-Sub
360°
RS 232 Open Wires
100 Hz
1000 Hz
Scanning frequency The CLV503 has a scanning frequency of 100 Hz. With its rotating mirror wheel, the CLV505 achieves a scanning frequency of 1,000 Hz and is thus also suitable for higher transport speeds of up to 5 m/s*).
Control elements of CLV503 *)
6
Image Processing
Electrical connection The devices of the Mini Line are available with pre-assembled USB cables, while the ICR803 is also available with an RS 232 cable. If, in the case of the CLV503/CLV505, the RS 232 interface is selected, variants are available with cables and open wire ends.
Image processing Thanks to camera technology, the ICR803 can capture and transmit images of objects with its WVGA chip.
Control elements of CLV505
Application-dependent
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
2009-04
Page 7
Product selection guide
Device feature
CLV503
Readable code types (see also page 9) OCR
1D
CLV505 Stacked
–
1D
ICR803 Stacked
1D
–
Stacked
2D
OCR Best before 2009-04-30
Code reading
Aligned
Omnidirectional
Aligned
360°
Scanning frequency
100 Hz
Electrical connections
USB
RS 232 Open Wires
Image processing
–
Technical data
●● From page 8
Readable code types/test codes
●● From page 9
Dimensional drawings and reading field diagrams
●● From page 10
Ordering information
●● From page 12
Accessories
●● From page 13
USB and open wire ends for CLV503/CLV505
2009-04
–
1000 Hz
USB
RS 232 Open Wires
USB
–
RS 232 D-Sub
Image Processing
●● From page 10
●● From page 11
Compact ICR803 housing – no moving parts
S ic k
|
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3
7
Page 8
Technical data
C LV 5 0 3 Scanner design
C LV 5 0 5
ICR803-A/-B
1D Code Reader
2D Image Code Reader
LED illumination
–
Visible red light (630 nm)
LED aiming line
–
Visible green light (530 nm)
Laser diode (wavelength)
Visible red light (650 nm)
–
Laser class of device
Light source
Class 2
–
MTTF2) of laser diode
10,000 h
–
Immunity to ambient light
2,000 lx
Max. 100,000 lx
Resolution
0.15 mm to 1.0 mm
ICR803-A: 0.19 mm (1D); 0.21 mm (2D) ICR803-B: 0.33 mm (1D); 0.38 mm (2D)
Usable aperture
Max. 44°
Max. 40°
–
Scanning /decoder frequency
100 Hz
1,000 Hz
–
Bar code print contrast (PCS)
90 %; min. 45 %
–
Acoustic indicators3)
Beeper (buzzer)
Beeper
Clock reading pulse
Digital input/command
Manual trigger, command or Presentation Mode, hardware trigger via CDB405
Data interfaces
USB keyboard wedge, USB serial, RS 232
USB keyboard wedge, USB serial, RS 232 TTL
Digital switching inputs
1 x input for clock reading pulse
–
Digital switching outputs
1 x GoodRead, 1 x NoRead
–
Electrical connection
1.5 m cable with USB or open wire ends
RJ45 socket: separate RJ45 cable to USB or 9-pin D Sub for RS 232
Operating voltage
5 V DC ± 10 %
Power consumption
Typ. 85 mA, max. 150 mA
Typ. 205 mA, max. 500 mA
Typ. 350 mA
Weight
18.5 g without cable
30 g without cable
37 g without cable
Dimensions
30 mm x 43.3 mm x 20 mm
29 mm x 34.5 mm x 17 mm
49 mm x 40 mm x 25 mm
Enclosure rating
IP 43
IP 54
–
Laser protection
JIS-C-6802 class 2, IEC 60825-1 class 2, FDA CDRH class II
EMC testing
Emission of interference acc. to EN 61000-6-3:2007-01; immunity to interference acc. to EN 61000-6-1:2007-014)
Product complies with
CE, FCC6), VCCI, RoHs
Operating temperature
–10 to 45 °C
0 to 45 °C
0 to 50 °C
Relative air humidity
20 to 85 %, non-condensing
5 to 90 %, non-condensing
5 to 95 %, non-condensing
1)
Emission of interference acc. to EN 61000-6-3:2007-01; immunity to interference acc. to EN 61000-6-2:2007-015)
– Emission of interference acc. to EN 55022:1998/A1:2000/ A2:2003 Class A ITE; immunity to interference acc. to EN 55024: 1998/A1:2001/ A2:2003 ITE CE, FCC6), RoHs
According to IEC 60825-1 and EN 60825-1, see warning sign on device for publication date; 2) MTTF = Mean Time To Failure; 3) Can be deactivated; 4) Protection from ESD is required by either grounded or ESD safe mounting. The USB cable length shall not exceed 3 m; CLV503-0000: Device must either be mounted on an isolated support or be protected from ESD; 5) Safe mounting with ESD; 6) FCC = Federal Communications Commission 1)
8
M i n i L i n e C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S ic k
2009-04