The text of a manual · part 7 of 18
Starnode PC Data Collection Network Operator's Manual, pages 61 to 70
Pages 61 to 70 of 172
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Computer Identics 320, Computer Identics 325, Computer Identics 326, RVSI CiMatrix 7500, RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, and 11 more models
Page 61
Controller I/O Base
Each time you click Display, the Status Table information is updated. When you are finished viewing the network's status, click Exit.
Network Menu The Network menu controls various aspects of system operation, such as starting or stopping network polling, resetting the communication statistics to zero, and more as shown in Figure 5–23. FIGURE 5–23. Starnode Utility Window - Network Menu
Clear Download Area - Allows you to delete all compiled *.LAN files from the controller's download area. Initialize Network - Allows you to begin polling the network and download programs automatically to all Starnode terminals. Unless the network has been stopped, the network should require initialization only once (usually at startup). Partial Init - Initializes the Starnode PC Interface Board without erasing program, error and type tables or downloading to the terminals. The board is made operational, and starts polling the network for messages. Configure Memory - Displays the Starnode Memory Configuration dialog box, which enables you to configure memory on the Starnode controller board, as shown in Figure 5–24. The warning against losing programs and messages stored the memory buffers.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
5-23
5 Using Starndem
Clear Status Table - Allows you to initialize the network status table described in the section above on the Status Table. You generally should initialize the network status table just before running the network diagnostics. After you select Clear Status Table from the action bar, the statuses are all reset to zero and begin accumulating again.
Page 62
Chapter
5
Using Starndem
FIGURE 5–24. Starnode Memory Configuration Dialog Box
Input message buffer and Priority message buffer share a pool of 64 buffers. (Each buffer is 512 bytes.) You must set a minimum of 1 buffer for normal input messages (default = 63) and 1 buffer for priority messages (default = 1). Input Page Buffers (16K each) configures the amount of memory to take from the user program download area and use for input messages (default = 0). Refer to Table 5–1 for the maximum you can take for each system option. Maximum settings for parameter 3, Input Page Buffers are shown in Table 5–1. TABLE 5–1. Input Page Buffer Settings
System with
Maximum Input
2 MB option
64
1 MB option
32
512K option
16
If you input invalid values for any of the three settings, you will cause the memory to reset to its defaults. Note: Starnode ROM 9.2 or higher is required. Use the “About” selection in the Help menu to see your ROM version. Call SICK Auto Ident, Inc. technical support if you need to upgrade your ROM. Clicking on the Set button provides the following actions: •
5-24
Flushes all downloaded programs
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 63
Controller I/O Base
•
Flushes all buffered messages
•
Stops network polling
•
Requires 2 minutes to complete settings in memory
Set the Starnode Memory Configuration only once. Wait 2 minutes before clicking Display to show your settings. If you attempt to display before 2 minutes are up, the Error dialog box will be displayed as shown in Figure 5–25. FIGURE 5–25. Error Dialog Box
A way to utilize Stop Network is to stop the network, close any open data files, then restart the Starndem Utility without full initialization. Data files could then be opened and the network initialized. This prevents any broadcast messages from being missed. Network Diagnostics - Open the Network menu and select Network Diagnostics to display the Starnode Diagnostics dialog box as shown in Figure 5–26. FIGURE 5–26. Starnode Diagnostics Window
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
5-25
5 Using Starndem
Stop Network - Allows you to stop the controller from polling terminals in the network. After selecting Stop Network, the network may not appear to stop immediately. This is because the controller may have already buffered up to 25 messages in memory before Stop Network was selected.
Page 64
Chapter
5
Using Starndem
Network Diagnostics Network Diagnostics is intended to test network communications by sending messages to and receiving messages from every terminal in the network. This communication can help you to determine if messages are being transmitted and received successfully and if there are any terminals in the network with identical terminal ID numbers. Note: The Windows Installation program should have stored a program named DIAG.LAN in the same directory as the Starndem Utility. Upon receiving DIAG.LAN, the Scanstar terminal should display: DIAGNOSTICS IN PROGRESS...DO NOT POWER OFF. Starndem Utility solicits a Diagnostic String message from each terminal in the network. The utility recognizes each active terminal and then downloads DIAG.LAN to each. The Starnode Diagnostics window offers the two menus, Tests and General as shown in Figure 5–27. FIGURE 5–27. Starnode Diagnostics Menus
When you select Tests, the various diagnostics tests are listed. Select a test to begin diagnostics. Diagnostic tests are supplied primarily for use by SICK Auto Ident, Inc. service personnel or when you are directed to perform diagnostics by a SICK Auto Ident, Inc. representative.
Setting Loop Count Many of the tests allow you to set a loop count. The default loop count is 4, however, this value can be overridden. The following tests use a loop count:
5-26
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 65
Network Diagnostics
•
All terminals simultaneously test
•
Each terminal sequentially test
•
One terminal test
•
Loop test
Each of these tests causes the Starndem Utility to send a message to the target terminals the number of times defined by the loop count. Before selecting a test, check the loop count and determine if it is set as desired. To set the loop count in preparation for a test, open the General menu and select Set Loop Count. This will display the Set Loop Count dialog box as shown in Figure 5–28. FIGURE 5–28. Set Loop Count Dialog Box
To set the loop count to a value other than the one shown, select the Loop Count field. Press Delete or Backspace to erase the current value. Type the new value. Click Set Count to apply the new value. You can move the dialog box and begin diagnostics, or you can select Exit to close the dialog box. Note: Ensure that you select Set Count before selecting Exit, otherwise no change in the loop count will be implemented. With the loop count set, you are ready to begin one of the tests. All Terminals Simultaneously - Open the Tests menu and select All Terminals Simultaneously to start the test. This test consists of two sub-tests. First, a series of messages is sent to every terminal in the network. The number of messages sent depends upon the loop count. Each message instructs the terminal to increment a counter. When all messages have been sent, a final message is broadcast to all terminals, instructing them to
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
5-27
Using Starndem
5
Page 66
Chapter
5
Using Starndem return their counter values. Any terminal that fails to return the proper counter value is identified on your monitor. The terminal currently being sent to, the current loop send count and the status of the tests are shown in a status line at the bottom of the Starnode Diagnostics window as shown in Figure 5–29. FIGURE 5–29. Starnode Diagnostics Window - Terminal No. & Send Count
Terminal Number / Current Send Count
During the one-way test, data flows in only one direction: either to or away from the Starnode terminals. During the two-way test, data is sent in both directions over the network. Instead of each terminal being instructed to increment a counter, the terminal is instructed to reply immediately. When the transmission loop count has been satisfied, the Starndem Utility verifies that each terminal responded the proper number of times. Any unexpected communication events are displayed as shown in Figure 5–30. FIGURE 5–30. Starnode Diagnostics Window, Unexpected Communications
If messages like this appear, examine the terminal that could not be contacted. Determine whether the terminal is still receiving the time from the Starnode controller.
5-28
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 67
Network Diagnostics
Note: If the terminal’s display has a period (.) to the right of the time and date, the terminal's own processor is supplying the time and date and may indicate a Starnode communication problem. Determine whether other terminals on that particular branch are communicating or not. Each Terminal Sequentially - Open the Tests menu and select Each Terminals Simultaneously to start the test. This test consists of two sub-tests and is similar to the All Terminals Simultaneously, except that it tests each terminal, one at a time, sequentially, by terminal ID. First, the utility sends a series of one-way messages to every terminal on the network. These messages are sent sequentially, by terminal ID. The response of each terminal is then checked. Once all terminals have been tested for one-way communication, two-way communication is tested. The number of messages sent during each test depends on the loop count. The terminal currently being sent to, the current loop send count and the status of the tests are shown in a status line at the bottom of the Starnode Diagnostics window.
FIGURE 5–31. Starnode Diagnostics
Note: If the terminal's display has a period (.) to the right of the time and date, the terminal's own processor is supplying the time and date and may indicate a Starnode communication problem. Determine whether other terminals on that particular branch are communicating or not. One Terminal - Open the Tests menu and select One Terminal to start the test and display the Test Terminal dialog box as shown in Figure 5–32.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
5 Using Starndem
When messages similar to the one shown in Figure 5–31 are sent, examine the terminal that could not be contacted. Determine whether the terminal is still receiving the time from the Starnode controller.
5-29
Page 68
Chapter
5
Using Starndem
FIGURE 5–32. Test Terminal Dialog Box
This test consists of two sub-tests. First, the utility sends a series of one-way messages to the target terminal. The response is checked. Once it has passed the one-way test, two-way communication is tested. The number of messages sent during each test depends on the loop count. The target terminal, the loop count, and the status of the tests are shown in a status line at the bottom of the Starnode Diagnostics window. This diagnostic tests one specified terminal. To specify the desired terminal, click on the Terminal ID field. Press Delete or Backspace to erase the current value. Type the new value. Click Test to start the test. You can move the dialog box and begin diagnostics, or you can select Exit to close the dialog box When the transmission loop count has been satisfied for each terminal, the Starndem Utility verifies that each terminal responded the proper number of times. Any unexpected communication events are reported as shown in Figure 5–33. FIGURE 5–33. Starnode Diagnostics - Target Terminal No. & Loop Count
Target Terminal Number / Loop Count
When messages similar to the one shown in Figure 5–33 are sent, examine the terminal that could not be contacted or view the terminal status through the Terminal Status selection. Determine whether the terminal is still receiving the time from the Starnode controller. If the terminal's display has a period (.) to the
5-30
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 69
Network Diagnostics right of the time and date, the terminal’s own processor is supplying the time and date and may indicate a Starnode communication problem. Determine whether other terminals on that particular branch are communicating or not. Loop Test - Causes the Starndem Utility to thoroughly test communications in the network. After Loop Test has been run, you may select Status Table or Status Summary. Display Status of Terminals - Causes the Starndem Utility to individually poll every Starnode ID address. When selected, the message Retrieving Terminal Status Information is displayed. All possible Starnode addresses are polled for status information and all non-zero statuses are shown. Ending the Current Test - Causes the diagnostics test currently running to be terminated.
Using Starndem
5
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
5-31
Page 70
Chapter
5
5-32
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Using Starndem