Page 41

Controller I/O Base

Default I/O Delay If the Starnode board seems to be generating random errors, try increasing the I/O delay through the Starnode utility. To change the value, click on the Default I/O Delay field and highlight the present value. Press the Delete or Backspace key to delete the current value. Then type in a new decimal value.

Full Initialization The Full Initialization field allows you to specify whether or not the Starndem Utility should download programs to terminals after it is started. During a full initialization: The controller's clock is set

•

The Starndem Utility solicits IDs from all terminals in the network

•

The Starnode board's download area is cleared

•

*.LAN files are downloaded to terminals by type when STARNDEM.CNF is found

Click the Help button if you need to view Help text for this dialog box. Otherwise, after the values in the Initialization dialog box are all satisfactory, click OK.

Starndem.cnf When you selected Full Initialization in the Initialization dialog box, the Starndem Utility looked for the STARNDEM.CNF file. This file is an ASCII text file containing terminal types and the *.LAN programs that will be downloaded to each terminal. Example A typical STARNDEM.CNF file may appear as follows: 1, E:\cisoft\badge.lan 3, workord.lan 8, E:\cisoft\shortcut.lan

Rev B, February 2002

Starnode PC Data Collection Network Operator’s Manual

5-3

5 Using Starndem

•

Page 42

Chapter

5

Using Starndem

These lines specify that all terminals identifying themselves as: type 1 should receive BADGE.LAN; type 3 terminals should receive WORKORD.LAN; and type 8 terminals should receive SHORTCUT.LAN. The Starndem Utility searches for STARNDEM.CNF in the same directory that contains the utility. When STARNDEM.CNF is found, the utility uses it to complete the full initialization. In using the contents of the configuration file to determine downloads, the utility looks again for the *.LAN files in the same directory as the Starndem Utility. If a *.LAN file is located in a different directory, you must specify the file's full path in the .CNF file record. Example When the sample configuration file in the previous example was accessed, the Initial Download Specifications dialog box is displayed as shown in Figure 5–2. FIGURE 5–2. Initial Download Specifications Dialog Box

Click OK when you are ready to begin Starndem Utility operation. The Initial Download Specifications dialog box disappears and the Starnode Utility main menu is displayed.

5-4

Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002

Page 43

Controller I/O Base

Starnode Utility Menus The Starnode Utility window contains the following menus, as shown in Figure 5–3. FIGURE 5–3. Starnode Utility Window

“Transmit Menu” on page 5-7

•

“Display Menu” on page 5-16

•

“Status Menu” on page 5-17

•

“Network Menu” on page 5-23

5 Using Starndem

•

File Menu File menu selections are shown in Figure 5–4. FIGURE 5–4. Starnode Utility Window - File Menu

Open & Close Data File - Opening the File menu and selecting Open Data File displays the Data File dialog box as shown in Figure 5–5. Open Data File causes the Starndem Utility to begin storing data to the indicated data file.

Rev B, February 2002

Starnode PC Data Collection Network Operator’s Manual

5-5

Page 44

Chapter

5

Using Starndem

FIGURE 5–5. Open Data File Dialog Box

Click on the data file name or type a complete path and data file name in the File Name field. To change the list of data files, click on a different path in the Files In' list box. After selecting a data file, click OK. If you specify a non-existent data file, the Starndem Utility creates the new data file and begins storing received transaction data to it. If a pre-existing data file is specified, the Append or Overwrite warning box is displayed as shown in Figure 5–6. FIGURE 5–6. Append or Overwrite Warning Box

When you click Yes, new data records are appended to the end of the preexisting data file. Opening the File menu and selecting Close Data File causes the Starndem Utility to discontinue storing records to the indicated data file. Exit - Opening the File menu and selecting Exit displays the Error dialog box as shown in Figure 5–7. Exit causes the Starndem Utility to exit.

5-6

Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002

Page 45

Controller I/O Base

FIGURE 5–7. Error Dialog Box

Clicking Yes will immediately stop the network. The next time that you start the Starndem Utility, a Y (Yes) appears as the starting Full Initialization field default. Clicking No will cause an N (No) to appear as the default at the next Starndem Utility startup. To change the response, click on the Full Initialization field and highlight the present value. Press the Delete or Backspace key to delete the current response, then type in either Y or N.

Transmit Menu The selections on the Transmit menu are all related to the sending of data to terminals in the Starnode network.

5 Using Starndem

FIGURE 5–8. Starnode Utility Window - Transmit Menu

Broadcast to All - Allows you to send a message or command to every terminal in the Starnode network. For example, you might want to send the message BREAK AT 10 AM to every terminal. 1.

Rev B, February 2002

Opening the Transmit menu and selecting Broadcast to All will display the Broadcast To All dialog box as shown in Figure 5–9.

Starnode PC Data Collection Network Operator’s Manual

5-7

Page 46

Chapter

5

Using Starndem

FIGURE 5–9. Broadcast To All Dialog Box

2.

Observe the Terminal Command box and determine whether the command shown is the one desired. If you wish to choose a different command, click the Terminal Command button to display the Terminal Command list box as shown in Figure 5–10.

FIGURE 5–10. Broadcast To All Dialog Box - Terminal Command List

Select the desired command type. Click OK when you are satisfied with the command type selected. Each terminal control command results in the addition of a single character to the massage. This command character tells the Scanstar terminal's operating system what to do with the message.

5-8

3.

If the command type selected allows you to send message text to the terminals, click on the Message entry field, otherwise, proceed to Step 5.

4.

Type a message of up to 126 characters (bytes) in the Message entry field. Messages longer than 126 characters (bytes) will not be transmitted. If you selected a command type of NONE, the first character (byte) you enter is used as a command byte by the terminal operating system.

Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002

Page 47

Controller I/O Base

Example When you select the command type NONE with the message 2HI THERE, the ASCII 2 at the beginning would be interpreted as a command byte. The decimal equivalent of the ASCII 2 is 49, so the 2 would mark the message as a Prompt message. The Message text can consist of non-printable ASCII characters or special Starnode screen control characters. For example, the prompt message \007 BREAK AT 10 AM would not only cause the message BREAK AT 10 AM to be displayed, but it would activate the beeper as well. Observe the Send with Attention check box. If the box is checked, an attention character will precede the message that you broadcast. This character causes a receiving terminal to stop whatever it is doing, such as hand-held laser scanning, and process the Starnode message or command immediately. This helps to ensure that the terminals ignore no broadcast messages. If an attention is not necessary, click on the check box. The check disappears and no attention character will be sent.

6.

When you are satisfied with the information shown in the Broadcast to All dialog box, click Broadcast. The selected command and message are transmitted to every terminal in the Starnode network.

Broadcast to Type - Allows you to send a message or command to terminals with a common type. For example, if you wanted to broadcast the Prompt message System Shutting Down to all type 008 terminals and terminal numbers 0001, 0005, and 0008 are type 008 terminals, only those terminals will receive the broadcast. 1.

Rev B, February 2002

Opening the Transmit menu and selecting Broadcast to Type will display the Broadcast to Type dialog box as shown in Figure 5–11.

Starnode PC Data Collection Network Operator’s Manual

5-9

5 Using Starndem

5.

Page 48

Chapter

5

Using Starndem

FIGURE 5–11. Broadcast To Type Dialog Box

2.

Determine the terminal type that you want to broadcast to. Click Terminal Type and enter the terminal type.

3.

Observe the Terminal Command box and determine whether the command shown is the one desired. If you wish to choose a different command, click the Terminal Command button to display the Terminal Command list box as shown in Figure 5–12.

FIGURE 5–12. Broadcast To Type Dialog Box - Terminal Command List

Select the desired command type. Click OK when you are satisfied with the command type selected. Each terminal control command results in the addition of a single character command identifier at the beginning of the message. This character tells the Scanstar terminal's operating system what to do with the message. 4.

5-10

If the command type selected allows you to send message text to the terminals, click on the Message entry field, otherwise, proceed Step 6.

Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002

Page 49

Controller I/O Base

5.

Type a message of up to 126 characters (bytes) in the Message entry field. Messages longer than 126 characters (bytes) will not be transmitted. Remember that if you selected a command type of NONE, the first character that you enter is used as a command byte. Example If you selected command type NONE with the message 2HI THERE, the ASCII 2 at the beginning would be interpreted as a command byte. The decimal equivalent of the ASCII 2 is 49, so the 2 would mark the message as a prompt. The Message text can consist of non-printable ASCII characters or special Starnode screen control characters. For example, the Prompt message \021 TIME TO QUIT would not only cause the message TIME TO QUIT to be shown, but it would cause the terminal's beeper to emit 3 short tones.

7.

Observe the Send with Attention box. When the box is enabled (checked), the message that you broadcast will be preceded by an attention character. This character causes a receiving terminal to stop whatever it is doing, such as hand-held laser scanning, and process the Starnode message or command immediately. This helps to ensure that terminals ignore no messages. If an attention is not necessary, disable (uncheck) Send with Attention box. The check disappears and no attention character will be sent. When you are satisfied with the information shown in the Broadcast to Type dialog box, click Broadcast. The selected command type message is transmitted to every terminal of the specified type in the Starnode network.

Message to Terminal - Allows you to send a message or command to a specific terminal in the Starnode network. For example, you may wish to send the prompt message YOU'RE LATE to terminal number 9. 1.

Rev B, February 2002

Opening the Transmit menu and selecting Message to Terminal will display the Send Terminal Message dialog box as shown in Figure 5–13.

Starnode PC Data Collection Network Operator’s Manual

5-11

5 Using Starndem

6.

Page 50

Chapter

5

Using Starndem

FIGURE 5–13. Send Terminal Message Dialog Box

2.

Determine the terminal number to which you want to transmit. Depending upon the type of Starnode controller, terminal numbers can be any positive integer between 0001 and 4095. Click on the Terminal Number entry field, then enter the terminal ID.

3.

Observe the Terminal Command box and determine whether the command shown is the one desired. If you want to choose a different command, click the Terminal Command button to display the Terminal Command list box as shown in Figure 5–14.

FIGURE 5–14. Send Terminal Message - Terminal Command List

Select the desired command. Click OK when you are satisfied with the command selected. Each terminal control command results in the addition of a single character to the beginning of the message. This character tells the Scanstar terminal's operating system what to do with the message.

5-12

Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002