Page 161
Network Troubleshooting
TABLE 10–1. Common Network Problems (Continued)
Possible Cause
Possible Solution
Terminals receive date and time only intermittently. Terminals fail to recognize that Starnode is up, or messages take a long time to be picked up.
Discontinuous cable shielding.
Check shield continuity through all T-tap boxes, or have a network verification done by Field Service.
A Y in the branch circuit.
Re-wire the branch circuit to be one long wire with a series of short drops. Install a U in the branch circuit to pick up the terminals that were previously on one branch of the Y.
Network operated until another Starnode device was added, or network operates normally except for devices connected to one branch circuit off the same Repeater.
Multiple terminating resistors.
Verify that only the last T-tap box on a branch circuit has a terminating resistor installed in it. Also verify that the T-tap closest to the Starnode board does not have a terminating resistor.
Network operates properly until Repeater is connected.
The interface cables are too short near the PC or Repeater.
Make sure there is at least 50 feet of branch circuit cable between the PC/Repeater and the Starnode device drop cable. If you have less than 50 feet, replace short cable with 50 feet of Starnode cable.
Starnode device does not receive a download table. Messages received are from a terminal type of 0.
Terminal type has not been setup - it has a type of 0.
Set Terminal Type of Starnode device.
Data transmissions between the terminal and PC are filled with error characters (default character is @) or incorrect data is received by receiving devices.
The baud rate or parity is not set correctly.
Check the baud rate and parity selected on both devices and reset them if necessary.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
10-5
10 Maintenance & Troubleshooting
Description of Problem
Page 162
Chapter
10 Maintenance & Troubleshooting
TABLE 10–1. Common Network Problems (Continued)
Description of Problem
Possible Cause
Possible Solution
Starnode device sends transactions to PC, occasionally with a type of 0, even though all terminals on the network have been assigned a non-zero type.
The particular Starnode device had a message sitting in the Starnode buffer when the Starnode network was initialized. Messages from terminals do not include the terminal type; this information is supplied by the Starnode board before the message is passed to the PC. In this instance, the Starnode board received the waiting message before it received the startup message containing the terminal's type.
Program your Starnode device not to send a message without checking the LAN status. If the LAN is not operating, do not do a PUT LAN.
When connecting a Starnode device serial port to another device using RS-232C communications, the other device hangs, fails to operate, or behaves erratically.
Ground loop problem exists.
Use the minimum number of conductors possible in the RS-232C cable. Usually pins 2, 3, and 7 are adequate for communications.
Too many conductors are in the cable linking the two devices.
Use the minimum number of conductors possible in the RS-232C cable. You may need to use only pins 1, 2, 3, 4, 5, and 7 (if you are using RTS/CTS), pins 1, 2, 3, and 7, or pins 2, 3, and 7.
When connecting a terminal to the Starnode network through a gateway terminal, the PC receives messages one character at a time.
The gateway terminal does not have its port set up in Block Mode.
Change the port parameters by entering the appropriate setup string. This may be done in a user program, or local setup of device.
Gateway terminal does not seem to receive anything when Block Mode is enabled.
The expected prefix character is not being received (if enabled), or suffix character is not being received.
Set up the prefix and suffix characters again for the serial port, double-checking that the device is sending them.
10-6
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 163
Network Troubleshooting
TABLE 10–1. Common Network Problems (Continued)
Possible Cause
Possible Solution
Serial port errors occur randomly on the Starnode device.
The error character is being received as part of the data sent from the device.
At the operating system level, or in your user setup string for the serial port (whichever is in effect at the time), change or disable the error character.
Starnode network does not seem to work.
Any of the causes listed in this section.
Run the STARNDEM program verifying that it does not report any errors when initializing the Starnode board. Turn on several data collection terminals and scan the LA label. Run diagnostics under STARNDEM. If diagnostics report several terminals on the network, and run to completion without reporting errors, the network works. The problem may be in your application program.
When keyboard on Starnode device is pressed, random characters are generated or all keys generate the same character.
A bad key or keyboard encoder chip.
Call SICK Auto Ident, Inc. to have the terminal repaired.
Terminal randomly resets to power-on state, with no error messages shown.
Intermittent power or improper grounding.
Check the reliability of your power supply by using a power line monitor to record spikes and brownouts. If power problems exist, install power line filters or some sort of filtering uninterruptible power supply system. Verify that all Starnode-related electrical outlets are properly grounded to a common earth ground.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
10-7
10 Maintenance & Troubleshooting
Description of Problem
Page 164
Chapter
10 Maintenance & Troubleshooting
10-8
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 165
A ASCII Equivalence
A ASCII Equivalence
APPENDIX A
This appendix contains the ASCII character set with decimal and hex equivalents for each character, and the keyboard strokes required to generate ASCII control characters.
ASCII Equivalence Table TABLE A–1. ASCII Equivalence Table
ASCII Character
Decimal
Hex
Keyboard
NULL
000
00
CTRL @
SOH (START OF HEADING)
001
01
CTRL A
STX (START OF TEXT)
002
02
CTRL B
ETX (END OF TEXT
003
03
CTRL C
EOT (END OF TRANSMISSION)
004
04
CTRL D
ENQ (ENQUIRY)
005
05
CTRL E
ACK (ACKNOWLEDGE)
006
06
CTRL F
BEL (BELL)
007
07
CTRL G
BS (BACKSPACE)
008
08
CTRL H
HT (HORIZONTAL TAB)
009
09
CTRL I
LF (LINE FEED)
010
0A
CTRL J
VT (VERTICAL TAB)
011
0B
CTRL K
FF (FORM FEED)
012
0C
CTRL L
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
A-1
Page 166
Chapter
A
ASCII Equivalence
TABLE A–1. ASCII Equivalence Table (Continued)
A-2
ASCII Character
Decimal
Hex
Keyboard
CR (CARRIAGE RETURN)
013
0D
CTRL M
SO (SHIFT OUT)
014
0E
CTRL N
SI (SHIFT IN)
015
0F
CTRL O
DLE (DATA LINK ESC)
016
10
CTRL P
DC1 (DATA CONTROL 1)
017
11
CTRL Q
DC2 (DATA CONTROL 2)
018
12
CTRL R
DC3 (DATA CONTROL 3)
019
13
CTRL S
DC4 (DATA CONTROL 4)
020
14
CTRL T
NAK (N0 ACKNOWLEDGE)
021
15
CTRL U
SYN (SYNCHRONOUS IDLE)
022
16
CTRL V
ETB (END OF TRANS. BLOCK)
023
17
CTRL W
CAN (CANCEL)
024
18
CTRL X
EM (END OF MEDIUM)
025
19
CTRL Y
SUB (SUBSTITUTE)
026
1A
CTRL Z
ESC (ESCAPE)
027
1B
CTRL [
FS (FILE SEPARATOR)
028
1C
CTRL \
GS (GROUP SEPARATOR)
029
1D
CTRL ]
RS (RECORD SEPARATOR)
030
1E
CTRL ^
US (UNIT SEPARATOR)
031
1F
CTRL _
SP (SPACE)
032
20
! (EXCLAMATION POINT)
033
21
" (QUOTE MARK)
034
22
# (POUND SIGN)
035
23
$ (DOLLAR SIGN)
036
24
% (PERCENT SIGN)
037
25
& (AMPERSAND)
038
26
' (APOSTROPHE)
039
27
( (LEFT PAREN)
040
28
) (RIGHT PAREN)
041
29
* (ASTERISK)
042
2A
+ (PLUS SIGN)
043
2B
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 167
TABLE A–1. ASCII Equivalence Table (Continued)
ASCII Character
Decimal
Hex
,(COMMA)
044
2C
- (MINUS SIGN)
045
2D
. (PERIOD)
046
2E
/ (SLASH)
047
2F
0
048
30
1
049
31
2
050
32
3
051
33
4
052
34
5
053
35
6
054
36
7
055
37
8
056
38
9
057
39
: (COLON)
058
3A
; (SEMI-COLON)
059
3B
<
060
3C
=
061
3D
>
062
3E
?
063
3F
@
064
40
A
065
41
B
066
42
C
067
43
D
068
44
E
069
45
F
070
46
G
071
47
H
072
48
I
073
49
J
074
4A
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
Keyboard
A-3
A ASCII Equivalence
ASCII Equivalence Table
Page 168
Chapter
A
ASCII Equivalence
TABLE A–1. ASCII Equivalence Table (Continued)
A-4
ASCII Character
Decimal
Hex
K
075
4B
L
076
4C
M
077
4D
N
078
4E
O
079
4F
P
080
50
Q
081
51
R
082
52
S
083
53
T
084
54
U
085
55
V
086
56
W
087
57
X
088
58
Y
089
59
Z
090
5A
[ (LEFT BRACKET)
091
5B
\ (BACKSLASH)
092
5C
] (RIGHT BRACKET)
093
5D
^ (UP ARROW)
094
5E
_ (UNDERLINE)
095
5F
' (ACCENT,GRAVE)
096
60 a
097
61 b
098
62 c
099
63 d
100
64 e
101
65 f
102
66 g
104
67 h
104
68 i
105
69
Keyboard
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 169
TABLE A–1. ASCII Equivalence Table (Continued)
ASCII Character
Decimal
Hex j
106
6A k
107
6B l
108
6C m
109
6D n
110
6E o
111
6F p
112
70 q
113
71 r
114
72 s
115
73 t
116
74 u
117
75 v
118
76 w
119
77 x
120
78 y
121
79 z
122
7A
{
123
7B
| (VERTICAL BAR)
124
7C
}
125
7D
~ (TILDE)
126
7E
DEL (DELETE)
127
7F
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
Keyboard
A-5
A ASCII Equivalence
ASCII Equivalence Table
Page 170
Chapter
A
A-6
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
ASCII Equivalence