Page 31

PREFIX & SUFFIX

INTERFACE RS-232

If you need to send information in addition to label data, the scanner can be configured to transmit prefixes and/or suffixes as well as symbology specific identifier characters. As the examples below show, none, one or two symbology specific ASCII characters can be added to the beginning of label in addition to multiple prefix and suffix characters. NOTE

Using this feature requires a thorough understanding of your specific system requirements. The seven options available using this feature are: • symbology specific (0 - 2) characters + label data PP + label data

• non-symbology specific characters (1-2) as a prefix + label data CpCp + label data

• label data + non-symbology specific characters (0-2) as a suffix label data + CsCs

• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data CpCp + PP + label data

• symbology specific characters (0-2) + label data + nonsymbology specific characters (1-2) as a suffix PP + label data + CsCs

• non-symbology specific characters (1-2) as a prefix + label data + non-symbology specific characters (1-2) as a suffix CpCp + label data + CsCs

• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data + non-symbology specific characters (1-2) as a suffix CpCp + PP + label data + CsCs

PP = symbology specific characters CpCp = non-symbology specific ASCII characters used as prefixes CsCs = non-symbology specific ASCII characters used as suffixes R44-1020

25

Page 32

SETTING NON-SYMBOLOGY SPECIFIC PREFIX(ES) These characters will be added to the standard label format when your host system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Identify your specific system requirements before adding or modifying these settings, then...

INTERFACE RS-232

1.

Look at the ASCII chart shown on page 30 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as prefixes. For example, if you are going to send two prefix characters as 'STX' (start transmit) and 'SP' (Space). The ASCII chart shows that 'STX' equals 02hex and 'SP' equals 20hex.

2.

Scan the SET label.

3.

Scan the Set Prefix label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step four, scan 0, 2, 2, 0.

5.

Scan END. You have added a two character prefix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET

------------------------------------SET PREFIX -------------------

GO TO PAGE 28 AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION .

26

SP400 Programming Guide

Page 33

SETTING NON-SYMBOLOGY SPECIFIC SUFFIX(ES)

Identify your specific system requirements before adding or modifying these settings, then... 1.

Look at the ASCII chart shown on page 30 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as suffixes. For example, if you are going to send two suffix characters as 'BEL' (sound host tone) and 'ETX' (end transmission). The ASCII chart shows that 'BEL' equals 07hex and 'ETX' equals 03hex .

2.

Scan the SET label.

3.

Scan the Set Suffix label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step five, scan 0, 7, 0, 3.

5.

Scan END. You have added a two character suffix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET

------------------------------------SET SUFFIX -------------------

GO TO PAGE 28 AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION .

R44-1020

27

INTERFACE RS-232

These characters will be added to the standard label format when your system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Suffix characters follow the label data.

Page 34

SETTING A SINGLE CHARACTER PREFIX OR SUFFIX To set one ASCII character as a prefix or suffix, follow steps one through four on page 26 or 27, then...

INTERFACE RS-232

1.

Scan the two digit Hex Code for that character. (e.g. 03, 8F, ...FF)

2.

Scan the One Character Only label on page 29.

3.

Scan the END label.

You have set a single character prefix or suffix.

SETTING PREFIX AND/OR SUFFIX CHARACTERS NOTE

You must scan the SET label and either the Set Prefix or Set Suffix label before using the labels on this page.

0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 -----------------------------

28

SP400 Programming Guide

Page 35 read from a scan by OCR; it may hold reading errors

_ - - _ {NN _ - - - {INI Wey fo Ho Li Ey Ze _ - I a IMMA a HT _ - I a IMM I a tM, - I a tM One Cuaracter Onty --------- lil | | 2p UM

R44-1020 °°

Page 36

ASCII CHARACTER SET The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters.

INTERFACE RS-232

30

ASCII C HAR .

HEX V ALUE

ASCII C HAR .

HEX V ALUE

ASCII C HAR .

HEX V ALUE

ASCII C HAR .

HEX V ALUE nul soh stx etx eot enq ack bel bs ht lf vt ff cr so si dle dc1 dc2 dc3 dc4 nak syn etb can em sub esc fs gs rs us

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F sp ! " # $ % & ' ( ) * + ' . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ del

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

SP400 Programming Guide

Page 37

SETTING SYMBOLOGY SPECIFIC IDENTIFIERS

1.

Look at the ASCII chart shown on page 30 and identify the ACSII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as the symbology specific identifiers.

2.

Scan the SET label on page 33.

3.

Scan the label identifier label for the symbology identifier that you are going to change on pages 33 and 34. As an example, assume that you want to change the label identifier for UPC-A to A1. Scan the Set Symbology Specific Identifier barcode for UPC-A.

4.

Identify the hex values that correspond to the ASCII characters you will use. For example, if you are going to set the new symbology identifier to A1. 'A' equals 41 hex and '1' equals 31 hex.

5.

Scan the barcodes values. For the example in step five, scan 4, 1, 3, 1.

6.

Scan END. You have changed the default label identifier for UPC-A from 'A' to 'A1'.

FACTORY SET SYMBOLOGY LABEL IDENTIFIERS This table shows the preset industry standard label identifiers that are contained in your scanner software. UPC-A ------------------------ 'A' UPC-E ------------------------ 'E' EAN-8 ----------------------- 'FF' EAN-13 ----------------------- 'F' UPC-D1 --------------------- 'D1' UPC-D2 --------------------- 'D2' UPC-D3 --------------------- 'D3' UPC-D4 --------------------- 'D4' UPC-D5 --------------------- 'D5' UPC-A (2 add-on) --------- 'A' UPC-A (5 Add-on) --------- 'A' UPC-E (2 add-on) --------- 'E' Code 49 ---------------------- 'T' R44-1020

UPC-E (5 Add-on) --------- 'E' EAN-8 (2 add-on) --------- 'FF' EAN-8 (5 Add-on) --------- 'FF' EAN-13 (2 add-on) -------- 'F' EAN-13 (5 Add-on) -------- 'F' Code 39 ---------------------- '*' Codabar --------------------- '%' Interleaved.2 of 5 ----------- 'i' Standard. 2 of 5 ------------- '!' Code 93 ---------------------- '&' Code 128 -------------------- '#' MSI/Plessey ---------------- '@' Code 16K --------------------- 'K'

31

INTERFACE RS-232

These characters identify what symbology is being sent to the host. If you need to change any of these defaults:

Page 38

HOW TO SET SINGLE CHARACTER SYMBOLOGY IDENTIFIERS If you only want a single character identifier, follow this modified procedure for setting label identifier.

INTERFACE RS-232

1.

Look at the ASCII chart shown on page 30 and identify the ASCII character and the corresponding Hex Code for the ASCII character you will use as the symbology specific identifier.

2.

Scan the SET label.

3.

Scan the label identifier label for the symbology identifier that you are going to change. As an example, assume that you want to change the label identifier for EAN-8 from the default setting FF to the ASCII value 8. Scan the Set Symbology Specific Label Identifier barcode for EAN-8.

5.

Identify the hex value that correspond to the ASCII character. In this example '8' equals 38 hex. Simply follow the hex value for '8' (38 hex) with the One Character Only label. This tells the scanner that '8' is a single digit label identifier.

6.

Scan the barcodes values. For the example in step five, scan 3, 8, One Character Only on pages 35 - 36.

7.

Scan the END label. You have changed the default label identifier for EAN-8 from 'FF' to '8'.

DISABLING INDIVIDUAL SYMBOLOGY IDENTIFIERS This procedure is the same as setting a single character symbology identifier, except you should scan two zeros and the One Character Only labels before scanning the END label.

32

SP400 Programming Guide

Page 39

SET

-------------------------------------

INTERFACE RS-232

UPC-A ---------------------UPC-A W/2 DIGIT ADD -ON ---UPC-A W/5 DIGIT ADD -ON ----

SET S YMBOLOGY S PECIFIC L ABEL I DENTIFIER FOR :

UPC-D1 -------------------UPC-D2 -------------------UPC-D3 -------------------UPC-D4 -------------------UPC-D5 -------------------UPC-E ---------------------UPC-E W /2 DIGIT ADD- ON ---UPC-E W /5 DIGIT ADD- ON ---EAN-8 ---------------------EAN-8 W /2 DIGIT ADD- ON ----R44-1020

33

Page 40

EAN-8 W/5 DIGIT ADD -ON ----EAN-13 --------------------INTERFACE RS-232

EAN-13 W /2 DIGIT ADD- ON ---

SET S YMBOLOGY S PECIFIC L ABEL I DENTIFIER FOR :

EAN-13 W /5 DIGIT ADD- ON --CODE 39 --------------------CODABAR ---------------------I NTERLEAVED 2 OF 5 ----------STANDARD 2 OF 5 ------------CODE 93 --------------------CODE 128 -------------------MSI/P LESSEY ---------------CODE 16K-------------------CODE 49 --------------------END

34

------------------------------------SP400 Programming Guide