Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 13

SP400 Programming Guide, pages 41 to 50

Pages 41 to 50 of 128

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC SP-400

Page 41

SYMBOLOGY SPECIFIC LABEL IDENTIFIERS CHARACTERS

INTERFACE RS-232

Use the labels on this page to change or modify symbology identifiers.

0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 -----------------------------

R44-1020

35

Page 42 read from a scan by OCR; it may hold reading errors

a CL a UT

3 5 C -nnnnonnnnnrononencnnncnnenns | ll | ll | | os

YR a | ANN On a | ANNUM ae AMM oom Ons Il

BNO | NON

36 SP400 Programming Guide

Page 43

Turn to the following pages to set the PC Keyboard Wedge communication parameters.

Page #

INTERFACE KEYBOARD WEDGE

Communication Parameter

Interface Selection ------------------------------------------------------------ 38 Connect to Laptop ------------------------------------------------------------ 39 Intercharacter Delay ---------------------------------------------------------- 40 Prefix and Suffix --------------------------------------------------------------- 42 Symbology Specific Identifiers --------------------------------------------- 48

Go to the sections title Symbology Selection and General Features in the back of this programming guide if you want to change any of the factory settings.

R44-1020

37

Page 44

PC KEYBOARD WEDGE INTERFACE SELECTION The SP400 supports six PC Keyboard Wedge interfaces. The table below defines the different interface selections. PCs Supported

A B C D E F

PC/XT w/foreign keyboard AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/foreign keyboard PS/2 25 and 30 w/foreign keyboard PC/XT w/US keyboard AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/US keyboard PS/2 25 and 30 w/US keyboard

SET

------------------------------------A ----------------------------B -----------------------------

INTERFACE (I/F) TYPE ( SEE TABLE ABOVE)

INTERFACE KEYBOARD WEDGE

I/F Type

C ----------------------------D ---------------------------E ----------------------------F -----------------------------

END

38

-------------------------------------

SP400 Programming Guide

Page 45

PC KEYBOARD WEDGE – CONNECT TO A LAPTOP

Scan the Laptop (integrated keyboard) label below when the scanner is connected to a laptop computer. If you move the scanner to a standard PC, change the setting to PC (external keyboard).

CONNECT TO L APTOP

SET

END

R44-1020

------------------------------------LAPTOP (INTEGRATED KEYBOARD)PC (EXTERNAL KEYBOARD ) ------------------------------------------

39

INTERFACE KEYBOARD WEDGE

When the SP400 is connected to a standard PC, the PC requires an acknowledge signal from the keyboard when processing data. A laptop computer, on the other hand, does not require this signal and it is necessary to disable the keyboard acknowledge signal.

Page 46

INTERCHARACTER DELAY

SET

------------------------------------= NONE ----------------------= 5 MILLISECONDS -------------

INTERCHARACTER D ELAY

INTERFACE KEYBOARD WEDGE

Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.

= 10 MILLISECONDS -----------= 15 MILLISECONDS -----------= 20 MILLISECONDS -----------= 25 MILLISECONDS -----------= 30 MILLISECONDS -----------= 35 MILLISECONDS -----------= 40 MILLISECONDS -----------= 45 MILLISECONDS -----------= 50 MILLISECONDS ------------

40

SP400 Programming Guide

Page 47

INTERFACE KEYBOARD WEDGE

INTERCHARACTER DELAY (continued)

= 55 MILLISECONDS -----------= 60 MILLISECONDS -----------= 65 MILLISECONDS ------------

INTERCHARACTER D ELAY

= 70 MILLISECONDS -----------= 75 MILLISECONDS -----------= 80 MILLISECONDS -----------= 85 MILLISECONDS -----------= 90 MILLISECONDS -----------= 95 MILLISECONDS -----------= 99 MILLISECONDS -----------END

R44-1020

-------------------------------------

41

Page 48

PREFIX & SUFFIX

INTERFACE KEYBOARD WEDGE

If you need to send information in addition to label data, the scanner can be configured to transmit prefixes and/or suffixes as well as symbology specific identifier characters. As the examples below show, none, one or two symbology specific ASCII characters can be added to the beginning of label in addition to multiple prefix and suffix characters. NOTE

Using this feature requires a thorough understanding of your specific system requirements. The seven options available using this feature are: •

•

•

•

•

•

• symbology specific characters (0 - 2) + label data PP + label data non-symbology specific characters as a prefix (1 or 2) + label data CpCp + label data label data + non-symbology specific characters as a suffix (0 - 2) label data + CsC s non-symbology specific characters as a prefix (1 - 2) + symbology specific characters (0 - 2) + label data CpCp + PP + label data symbology specific characters (0 - 2) + label data + non-symbology specific characters as a suffix (1 - 2) PP + label data + CsCs non-symbology specific characters as a prefix (1 - 2) + label data + non-symbology specific characters as a suffix (1 - 2) CpCp + label data + CsC s non-symbology specific characters as a prefix (1 - 2) + symbology specific characters (0 - 2) + label data + non-symbology specific characters as a suffix (1 - 2) CpCp + PP + label data + CsCs

PP = symbology specific characters CpCp = non-symbology specific ASCII characters used as prefixes CsCs = non-symbology specific ASCII characters used as suffixes

42

SP400 Programming Guide

Page 49

These characters will be added to the standard label format when your host system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Identify your specific system requirements before adding or modifying these settings, then... 1.

Look at the ASCII chart shown on page 47 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as prefixes. For example, if you are going to send two prefix characters as 'STX' (start transmit) and 'SP' (Space). The ASCII chart shows that 'STX' equals 02hex and 'SP' equals 20hex.

2.

Scan the SET label.

3.

Scan the Set Prefix label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step four, scan 0, 2, 2, 0.

5.

Scan END. You have added a two character prefix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET

------------------------------------SET PREFIX -------------------

GO TO PAGE 45 AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION .

R44-1020

43

INTERFACE KEYBOARD WEDGE

SETTING NON-SYMBOLOGY SPECIFIC PREFIX(ES)

Page 50

SETTING NON-SYMBOLOGY SPECIFIC SUFFIX(ES)

INTERFACE KEYBOARD WEDGE

These characters will be added to the standard label format when your system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Suffix characters follow the label data. Identify your specific system requirements before adding or modifying these settings, then... 1.

Look at the ASCII chart shown on page 47 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as suffixes. For example, if you are going to send two suffix characters as 'BEL' (sound host tone) and 'ETX' (end transmission). The ASCII chart shows that 'BEL' equals 07 hex and 'ETX' equals 03 hex .

2.

Scan the SET label.

3.

Scan the Set Suffix label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step five, scan 0, 7, 0, 3.

5.

Scan END. You have added a two character suffix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET

------------------------------------SET S UFFIX -------------------

G O TO PAGE 45 AND SCAN THE APPROPRIATE CHARACTERS BEFORE END LABEL TO EXIT PROGRAMMING SESSION.

SCANNING THE

44

SP400 Programming Guide