The text of a manual · part 3 of 13
SP400 Programming Guide, pages 21 to 30
Pages 21 to 30 of 128
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC SP-400
Page 21
WAND EMULATION INTERFACE SELECTION
INTERFACE WAND EMULATION
Scan this label to enable the Wand Emulation interface.
SET
-------------------------------------
POLARITY
WAND EMULATION SETTINGS
SPACE LOW, BAR H IGH --------
SIGNAL S PEED
LOW (660 µS ) ---------------
DATA F ORMAT
NORMAL -----------------------
IDLE S TATE
SPACE H IGH, BAR L OW --------
LOW --------------------------
END
-------------------------------------
HIGH (330 µS ) --------------
SEND AS CODE 39 ------------
HIGH --------------------------
Go to the sections title Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface. R44-1020
15
Page 22
SIX-BIT INTERFACES Scan the appropriate interface enable label to activate the scanner interface that matches you system type.
SELECT /ENABLE I NTERFACE
INTERFACE SIX-BIT
SET
------------------------------------O MRON ----------------------F UJITSU ----------------------CLOVER/F UJITSU --------------H UGIN SWEDA -----------------
END
-------------------------------------
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.
16
SP400 Programming Guide
Page 23
RS-232 INTERFACE SELECTION
Turn to the following pages to set the RS-232 communication parameters.
Communication Parameter
Page #
Baud Rate ------------------------------------------------------------------ 18 Parity ------------------------------------------------------------------------ 19 Stop Bit(s) ----------------------------------------------------------------- 19 Data Bits ------------------------------------------------------------------- 19 Hardware Handshaking (CTS/RTS) --------------------------------- 20 Software Handshaking (Xon/Xoff) ---------------------------------- 20 UPC Data Format (Check Digit, Number System Digit) ------- 21 EAN Data Format -------------------------------------------------------- 22 Intercharacter Delay ---------------------------------------------------- 23 Prefix and Suffix --------------------------------------------------------- 25 Symbology Specific Identifiers --------------------------------------- 31
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.
R44-1020
17
INTERFACE RS-232
Scan this label to enable the RS-232 interface.
Page 24
BAUD RATE Use the barcodes on this page to select the communications Baud Rate. Only one Baud Rate selection may be active at any one time. The last Baud Rate label you scan during a programming session will be the setting that is stored when you scan the END label.
INTERFACE RS-232
SET
------------------------------------= 1102 --------------------------------= 300 -----------------------
BAUD R ATE
= 600 ----------------------= 1200 ---------------------= 2400 ---------------------= 4800 ---------------------= 9600 ---------------------= 19200 -------------------1
Only units manufactured after June 1, 1995 can use the 38,400 baud label below. To reset from 38,400 baud to 110 baud, use the “Reset 110 baud” label below.
38,400 BAUD
2
= 38,4001 ---------------------
END
-------------------------------------
18
= RESET 110 2 -----------------
SP400 Programming Guide
Page 25
DATA FORMAT SETTINGS There are many possible data format configurations for an RS-232 interface. Check your host system manual to find out your system's communications requirements. This table shows the acceptable format options.
SET
Start Bit 1 1 1 1 1 1 1
Parity Bit(s) 0 1 1 0 0 1 0
Stop Bit(s) 2 1 2 1 2 1 1
INTERFACE RS-232
Data Bits Seven Seven Seven Eight Eight Eight Nine
-------------------------------------
PARITY
NONE ------------------------EVEN --------------------------
STOP B ITS
ODD -------------------------ONE -------------------------TWO --------------------------
D ATA BITS
SEVEN B ITS ------------------EIGHT B ITS -------------------NINE BITS --------------------END R44-1020
-------------------------------------
19
Page 26
HANDSHAKING Review your system documentation to identify system handshaking requirements, and use these labels to change the setting if required. The following brief descriptions explain each handshaking selection.
XON/XOFF, this is software handshaking that allows the host to control data transmission. If the host sends an XOFF command to the scanner, the scanner will not send the barcode data until it receives an XON command from the host. If the host sends the XOFF command during data transmission, the host will receive no more than two additional characters.
SET
------------------------------------E NABLE CTS/RTS -----------
HANDSHAKING
INTERFACE RS-232
CTS/RTS, the scanner activates the RTS (Ready to Send) line when it is ready to send data to the host. The scanner waits for an active Clear to Send (CTS) signal from the host before transmitting data. The RTS line from the scanner is active during data transmission and returns to inactive when the data transmission has been completed. If the host deactivates the CTS line during data transmission, the host will receive no more than two additional characters.
DISABLE CTS/RTS ----------E NABLE XON / X OFF -----------DISABLE X ON /XOFF ------------
END
20
-------------------------------------
SP400 Programming Guide
Page 27
UPC DATA FORMAT SETTINGS These settings affect UPC data format ONLY when RS-232 is the active interface.
------------------------------------INTERFACE RS-232
SET
SEND CHECK D IGIT ------------
UPC-A
D ON' T SEND CHECK D IGIT ----SEND NSD1 -----------------D ON' T SEND NSD1 ----------SEND CHECK D IGIT2 -----------
UPC-E
D ON' T SEND CHECK D IGIT2 ----SEND NSD2 -----------------D ON' T SEND NSD2 ----------END 1
2
-------------------------------------
NSD = Number System Digit. The NSD character is the character that precedes the UPC barcode. The NSD for regular UPC-A barcodes is a zero. Other commonly used Number System Digits used with UPC-A are: 2 - used for random weight items such as meat and produce 3 - used for the drug and health items 4 - used for in-store non-food items 5 - used for coupons If UPC-E is expanded to UPC-A, the transmission of CD and NSD will be determined by the UPC-A settings on this page, not by these settings.
R44-1020
21
Page 28
EAN DATA FORMAT SETTINGS These settings affect EAN data format ONLY when RS-232 is the active interface.
SET
EAN-13
EAN-8
INTERFACE RS-232
END
------------------------------------SEND C HECK D IGIT -----------DON 'T S END C HECK D IGIT ----SEND C HECK D IGIT -----------DON 'T S END C HECK D IGIT ----------------------------------------HOST ECHO1
SET
-------------------------------------
H OST ECHO
Host Echo allows a dumb terminal (Host) to transmit keyboard data through the scanner (Echo) to a main computer. Scanned label data will take priority over keyboard data.
E NABLE HOST ECHO ------------
END
-------------------------------------
D ISABLE H OST E CHO -----------
1
This feature not available on units manufactured before Mar. 1, 1995.
22
SP400 Programming Guide
Page 29
INTERCHARACTER DELAY
SET
INTERFACE RS-232
Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.
------------------------------------= N ONE -----------------------
INTERCHARACTER D ELAY
= 10 MILLISECONDS -----------= 20 MILLISECONDS -----------= 30 MILLISECONDS -----------= 40 MILLISECONDS -----------= 50 MILLISECONDS -----------= 60 MILLISECONDS ------------
R44-1020
23
Page 30
INTERCHARACTER DELAY (continued)
INTERFACE RS-232 = 70 MILLISECONDS -----------= 80 MILLISECONDS ------------
INTERCHARACTER D ELAY
= 90 MILLISECONDS -----------= 100 MILLISECONDS ---------= 110 MILLISECONDS ---------= 120 MILLISECONDS ---------= 130 MILLISECONDS ---------= 140 MILLISECONDS ---------END
24
-------------------------------------
SP400 Programming Guide