Page 11

Every time you change the active interface, a new set of factory settings are enabled (refer to Appendix A, Standard Factory Settings, for a complete list) and any changes that you want to make must be made to that interface's factory settings. Previous changes made to other interface settings are stored as that specific interface's configuration settings for future use when you re-enable that interface. This allows the scanner to retain a special configuration file for each interface. Once you have changed cables and enabled the new interface, it may be necessary to modify the standard factory settings to match your specific host system's communication and symbology requirements. Check with your system administrator to identify your host system's specific interface requirements to ensure that they match the new interface you have selected. Also, the scanner's operational features (e.g. speaker tone and volume) can be customized to match your unique requirements. 1.

Use the labels in this manual to modify the standard configuration to match your specific interface requirements or user preference.

2.

Enable any additional symbologies as required and exit Programming Mode.

3.

Scan a regular barcode label and verify that the scanner and host communicate correctly.

4.

You have completed the factory settings change procedure.

If you change the interface again, these settings will be saved as the default settings for this interface only. If you experience difficulties, have questions or require additional information, contact your local distributor or PSC Customer Support Services at 1-800-547-2507.

R44-1020

5

GENERAL INFORMATION

CUSTOMIZING YOUR SCANNER OPERATION

Page 12

GENERAL INFORMATION

PROGRAMMING OVERVIEW This section describes how to set the scanner's programmable features. These features can be configured using the barcode labels contained in this manual or by using commands sent from the host. Refer to Appendix B, Additional Information, for host programming details. If you program the scanner using these barcodes, the scanner stores the changes until reprogrammed. Whenever you use these labels to change programmable features, you are changing these features for the active interface only.

WHAT IS PROGRAMMING MODE? To change the scanner's programmed settings, it is necessary to place the scanner in Programming Mode. This ensures that the scanner only recognizes the special programming labels contained in this programming guide.

HOW TO PROGRAM USING BARCODES The following pages contain special barcode labels that are used to change or enable the scanner's programmable options. All programming sessions follow this order: 1.

Scan the SET label at the top of the page. The scanner will emit a low-to-high tone indicating it has read the label, and will then begin flashing the green lamp. As long as the scanner is flashing the green lamp, the scanner will only recognize and decode programming labels.

2.

Scan the feature label(s) for the programmable options you wish to enable. The scanner will emit a low-to-high tone each time you scan a valid label indicating it has read and decoded the programming label. (All features are not available for all interfaces.)

3.

Scan the END label at the bottom of the page to complete the programming session and exit Programming Mode.

You can scan any number of feature labels during a programming session before scanning the END label, but you must scan the END label to save changes and exit Programming Mode. The scanner will not exit Programming Mode unless the END label is scanned. Disconnecting power during Programming Mode, before scanning the END label, will cause the scanner to forget any programming labels scanned during the current programming session and will cause the scanner to return to its previous settings.

6

SP400 Programming Guide

Page 13

While in Programming Mode, the scanner will not decode regular barcode labels and will only enable features supported by the currently active interface. Maintaining a good record of all changes made for each interface will help ensure that you know if the standard factory settings have been changed. Scanning regular barcode labels, the scanner will not read the label and will not sound a tone. Scanning a valid programming label, a.

If the feature is supported by the active interface, the scanner will sound a low-to-high tone. This is the same tone that sounds when you enter Programming Mode.

b. If the feature is not supported by the active interface, the scanner will sound a long low tone. For example, if the active interface is OCIA and you scan an RS-232 interface parameter (e.g. Baud Rate = 9600), the scanner will sound a long low tone.

IF YOU MAKE A MISTAKE... If, during a programming session, you find that you are unsure of the scanner's settings or wish to re-set the scanner's configuration, use the Return to Factory Settings label on this page to return the scanner's configuration to the factory settings. Scanning this label only affects the interface that is currently active, and will reset any changes made to this interface during a previous programming session. Appendix A contains a complete list of all standard factory settings.

RETURN TO FACTORY SETTINGS Scan this label to return the scanner to the factory settings for the active interface.

R44-1020

7

GENERAL INFORMATION

SCANNER RESPONSE WHEN IN PROGRAMMING MODE

Page 14

GENERAL INFORMATION

WHERE TO GO FROM HERE Programming is easy and straightforward if you follow these steps: 1.

Turn to Appendix A and review the factory settings for the interface you will be using.

2.

Scan the interface enable barcode label if you are changing interfaces.

3.

Scan any feature labels that are unique to the interface you are currently programming. These interface specific programming labels immediately follow each interface selection label.

5.

Turn to page 54 if you are going to change any barcode symbologies or modify any symbology related features.

6.

Turn to page 79 if you wish to change or modify any of the scanner's general features.

Once the necessary changes have been made, and you have scanned the END label, you are ready to scan.

8

SP400 Programming Guide

Page 15

IBM 468X PORT 5B INTERFACE SELECTION

INTERFACE IBM PORT 5B

Scan this label to enable the IBM 468x Port 5B interface.

IBM 468X PORT 5B SETTINGS Data Format: Send As Code 39, converts barcode data (UPC-D, UPC/ EAN, add-ons, Code 93, Standard 2 of 5, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host.

SET

-------------------------------------

DATA F ORMAT

These settings are for IBM 468x Port 5B interface ONLY.

SEND AS CODE 39 ------------

END

-------------------------------------

D ON' T SEND AS CODE 39------

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

R44-1020

9

Page 16

IBM 468X/9X PORT 9B INTERFACE SELECTION Scan this label to enable the IBM 468x/9x Port 9B interface.

INTERFACE IBM PORT 9B

IBM 468X/9X PORT 9B SETTINGS Data Format: Send As Code 39, converts barcode data (UPC-D, UPC/ EAN, add-ons, Code 93, Standard 2 of 5, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host.

SET

-------------------------------------

DATA F ORMAT

These settings are for IBM 468x/9x Port 9B interface ONLY.

SEND AS CODE 39 ------------

END

-------------------------------------

D ON' T SEND AS CODE 39------

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

10

SP400 Programming Guide

Page 17

IBM 468X PORT 17 INTERFACE SELECTION

INTERFACE IBM PORT 17

Scan this label to enable the IBM 468x Port 17 interface.

IBM 468X PORT 17 SETTINGS Data Format: Send As Code 39, converts barcode data (UPC-D, UPC/ EAN, add-ons, Code 93, Standard 2 of 5, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host.

SET

-------------------------------------

DATA F ORMAT

These settings are for IBM 468x Port 17 interface ONLY.

SEND AS CODE 39 ------------

END

-------------------------------------

DON 'T S END AS CODE 39 ------

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

R44-1020

11

Page 18

IBM 468X/9X PORT E INTERFACE SELECTION Scan this label to enable the IBM 468x/9x Port E interface.

INTERFACE IBM PORT E

IBM 468X/9X PORT E SETTINGS Data Format: Send As Code 39, converts barcode data (UPC-D, UPC/ EAN, add-ons, Code 93, Standard 2 of 5, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 468x/9x Port E interface ONLY.

SET

------------------------------------SEND AS C ODE 39 -----------DON ' T SEND AS C ODE 39------

END

-------------------------------------

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

12

SP400 Programming Guide

Page 19

PSC OCIA INTERFACE SELECTION

INTERFACE OCIA customized PSC OCIA interface. Scan this label to enable the Spectra-Physics

NCR OCIA EIGHT BIT (SHORT FORMAT) INTERFACE SELECTION Scan this label to enable the NCR OCIA (short format) interface.

NCR OCIA NINE BIT (LONG FORMAT) INTERFACE SELECTION Scan this label to enable the NCR OCIA Nine Bit (long format) interface.

SNI OCIA INTERFACE SELECTION Scan this label to enable the SNI OCIA interface.

METROLOGIC OCIA INTERFACE SELECTION Scan this label to enable the Metrologic OCIA interface.

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for these interfaces.

R44-1020

13

Page 20

MULTIDROP INTERFACE SELECTION Scan the Enable Interface label to select multidrop as the active interface. Your system configuration will determine which peripheral ID setting to select.

INTERFACE MULTIDROP

MULTIDROP SETTINGS

SET

-------------------------------------

SET P ERIPHERAL ID

ID = 70 --------------------ID = 71 --------------------ID = 72 --------------------ID = 73 --------------------END

-------------------------------------

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

14

SP400 Programming Guide