The text of a manual · part 12 of 13
SP400 Programming Guide, pages 111 to 120
Pages 111 to 120 of 128
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC SP-400
Page 111
RS-232 Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
COMMUNICATION PARAMETERS 1200 19200
30ms 70ms 110ms
APPENDIX A STD. DEFAULTS
B AUD R ATE ----------------------------- 110 300 600 ----------------------------- 2400 4800 9600 P ARITY ----------------------------- NONE Even Odd S TOP BITS ----------------------------- ONE Two D ATA BITS ----------------------------- Seven EIGHT Nine H ARDWARE HANDSHAKING (CTS/RTS) ----------------------------- Enable DISABLE S OFTWARE HANDSHAKING (XON/XOFF) ----------------------------- ENABLE Disable INTERCHARACTER DELAY ----------------------------- NONE 10ms 20ms ----------------------------- 40ms 50ms 60ms ----------------------------- 80ms 90ms 100ms ----------------------------- 120ms 130ms 140ms CTS S CAN CONTROL ----------------------------- Enable DISABLE P REFIX/SUFFIX Prefix ---------------------- NONE Suffix ---------------------- SEND AS CARRIAGE RETURN
SYMBOLOGY SELECTION UPC/EAN Symbology -------------------------------ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ----------------------------------Required UPC-E Check Digit --------------------- SEND UPC-E Number System Digit --------- SEND UPC-A Check Digit --------------------- SEND UPC-A Number System Digit --------- SEND R44-1020
Disable DISABLE ENABLE DISABLE DISABLE DISABLE Optional DISABLE Don't Send Don't Send Don't Send Don't Send
105
Page 112
APPENDIX A STD. DEFAULTS
CODE 39 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Read One Character Label ------------ Enable DISABLE INTERLEAVED 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 STANDARD 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD --------------------------------------------- abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE ITALIAN CODE 39 Symbology ------------------------------- Enable DISABLE CODE 5 Symbology ------------------------------- Enable DISABLE CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- ENABLE Disable CODE 128 Symbology ------------------------------- ENABLE Disable MSI/PLESSEY Symbology ------------------------------- ENABLE Disable
106
SP400 Programming Guide
Page 113
RS-232 GENERAL FEATURES These features can be used to customize the user interface features. AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 2 read 3 read
Long High
4 read
DEFAULT SYMBOLOGY IDENTIFIERS
R44-1020
SEND AS 'A' SEND AS 'E' SEND AS 'FF' SEND AS 'F' SEND AS 'D1' SEND AS 'D2' SEND AS 'D3' SEND AS 'D4' SEND AS 'D5' SEND AS 'A' SEND AS 'A' SEND AS 'E' SEND AS 'E' SEND AS 'FF' SEND AS 'FF' SEND AS 'F' SEND AS 'F' SEND AS '*' SEND AS '%' SEND AS 'i' SEND AS '!' SEND AS '&' SEND AS '#' SEND AS '@'
APPENDIX A STD. DEFAULTS
UPC-A --------------------- Don't Send UPC-E --------------------- Don't Send EAN-8 --------------------- Don't Send EAN-13 ------------------- Don't Send UPC-D1 ------------------- Don't Send UPC-D2 ------------------- Don't Send UPC-D3 ------------------- Don't Send UPC-D4 ------------------- Don't Send UPC-D5 ------------------- Don't Send UPC-A (2 add-on) ------ Don't Send UPC-A (5 Add-on) ------ Don't Send UPC-E (2 add-on) ------ Don't Send UPC-E (5 Add-on) ------ Don't Send EAN-8 (2 add-on) ------- Don't Send EAN-8 (5 Add-on) ------ Don't Send EAN-13 (2 add-on) ----- Don't Send EAN-13 (5 Add-on) ----- Don't Send Code 39 ------------------ Don't Send Codabar ------------------ Don't Send Ind.2 of 5 ----------------- Don't Send Std. 2 of 5---------------- Don't Send Code 93 ------------------ Don't Send Code 128 ----------------- Don't Send MSI/Plessey ------------- Don't Send Code 49 ------------------ NONE Code 16K ----------------- NONE
107
Page 114
PC KEYBOARD WEDGE Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
COMMUNICATION PARAMETERS INTERCHARACTER DELAY ----------------------------- NONE 5ms 10ms ----------------------------- 20ms 25ms 30ms ----------------------------- 40ms 45ms 50ms ----------------------------- 60ms PREFIX /SUFFIX Prefix ---------------------- SET TO NUL Suffix ---------------------- SEND AS CARRIAGE RETURN
15ms 35ms 55ms
SYMBOLOGY SELECTION
APPENDIX A STD. DEFAULTS
UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE ENABLE DISABLE DISABLE DISABLE OPTIONAL Disable
CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable
Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE
108
SP400 Programming Guide
Page 115
PC KEYBOARD WEDGE (CONT.) Disable DON'T CALCULATE Don't Send VARIABLE LENGTH
STANDARD 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ Send DON'T SEND Start/Stop Character ------------------- Send DON'T SEND Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD --------------------------------------------- abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE ITALIAN CODE 39 Symbology ------------------------------- Enable DISABLE CODE 5 Symbology ------------------------------- Enable DISABLE CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- ENABLE Disable CODE 128 Symbology ------------------------------- ENABLE Disable MSI/PLESSEY Symbology ------------------------------- ENABLE Disable
R44-1020
109
APPENDIX A STD. DEFAULTS
INTERLEAVED 2 OF 5 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8
Page 116
PC KEYBOARD WEDGE GENERAL FEATURES These features can be used to customize the user interface features. AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ V ERIFICATION ----------------------------- 1 READ
2 read
3 read
Long High
4 read
DEFAULT SYMBOLOGY IDENTIFIERS
APPENDIX A STD. DEFAULTS
UPC-A ----------------------------------------------------- NONE UPC-E ----------------------------------------------------- NONE EAN-8 ----------------------------------------------------- NONE EAN-13 --------------------------------------------------- NONE UPC-D1 --------------------------------------------------- NONE UPC-D2 --------------------------------------------------- NONE UPC-D3 --------------------------------------------------- NONE UPC-D4 --------------------------------------------------- NONE UPC-D5 --------------------------------------------------- NONE UPC-A (2 add-on) -------------------------------------- NONE UPC-A (5 Add-on) -------------------------------------- NONE UPC-E (2 add-on) -------------------------------------- NONE UPC-E (5 Add-on) -------------------------------------- NONE EAN-8 (2 add-on) --------------------------------------- NONE EAN-8 (5 Add-on) -------------------------------------- NONE EAN-13 (2 add-on) ------------------------------------- NONE EAN-13 (5 Add-on) ------------------------------------- NONE Code 39 -------------------------------------------------- NONE Codabar -------------------------------------------------- NONE Ind.2 of 5 ------------------------------------------------- NONE Std. 2 of 5------------------------------------------------ NONE Code 93 -------------------------------------------------- NONE Code 128 ------------------------------------------------- NONE MSI/Plessey --------------------------------------------- NONE Code 49 -------------------------------------------------- NONE Code 16K ------------------------------------------------- NONE
110
SP400 Programming Guide
Page 117
SIX-BIT (OMRON) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable
DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE
DISABLE
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE
R44-1020
111
APPENDIX A STD. DEFAULTS
DISABLE
Page 118
ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable
DISABLE DISABLE DISABLE DISABLE DISABLE
DISABLE
GENERAL FEATURES
APPENDIX A STD. DEFAULTS
AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ
112
2 read
3 read
Long High
4 read
SP400 Programming Guide
Page 119
SIX-BIT (FUJITSU) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable
DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE
DISABLE
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE
R44-1020
113
APPENDIX A STD. DEFAULTS
DISABLE
Page 120
ITALIAN C ODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable
DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE
GENERAL FEATURES
APPENDIX A STD. DEFAULTS
AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ V ERIFICATION ----------------------------- 1 READ
114
2 read
3 read
Long High
4 read
SP400 Programming Guide