Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 13

SP400 Programming Guide, pages 111 to 120

Pages 111 to 120 of 128

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC SP-400

Page 111

RS-232 Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

COMMUNICATION PARAMETERS 1200 19200

30ms 70ms 110ms

APPENDIX A STD. DEFAULTS

B AUD R ATE ----------------------------- 110 300 600 ----------------------------- 2400 4800 9600 P ARITY ----------------------------- NONE Even Odd S TOP BITS ----------------------------- ONE Two D ATA BITS ----------------------------- Seven EIGHT Nine H ARDWARE HANDSHAKING (CTS/RTS) ----------------------------- Enable DISABLE S OFTWARE HANDSHAKING (XON/XOFF) ----------------------------- ENABLE Disable INTERCHARACTER DELAY ----------------------------- NONE 10ms 20ms ----------------------------- 40ms 50ms 60ms ----------------------------- 80ms 90ms 100ms ----------------------------- 120ms 130ms 140ms CTS S CAN CONTROL ----------------------------- Enable DISABLE P REFIX/SUFFIX Prefix ---------------------- NONE Suffix ---------------------- SEND AS CARRIAGE RETURN

SYMBOLOGY SELECTION UPC/EAN Symbology -------------------------------ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ----------------------------------Required UPC-E Check Digit --------------------- SEND UPC-E Number System Digit --------- SEND UPC-A Check Digit --------------------- SEND UPC-A Number System Digit --------- SEND R44-1020

Disable DISABLE ENABLE DISABLE DISABLE DISABLE Optional DISABLE Don't Send Don't Send Don't Send Don't Send

105

Page 112

APPENDIX A STD. DEFAULTS

CODE 39 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Read One Character Label ------------ Enable DISABLE INTERLEAVED 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 STANDARD 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD --------------------------------------------- abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE ITALIAN CODE 39 Symbology ------------------------------- Enable DISABLE CODE 5 Symbology ------------------------------- Enable DISABLE CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- ENABLE Disable CODE 128 Symbology ------------------------------- ENABLE Disable MSI/PLESSEY Symbology ------------------------------- ENABLE Disable

106

SP400 Programming Guide

Page 113

RS-232 GENERAL FEATURES These features can be used to customize the user interface features. AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 2 read 3 read

Long High

4 read

DEFAULT SYMBOLOGY IDENTIFIERS

R44-1020

SEND AS 'A' SEND AS 'E' SEND AS 'FF' SEND AS 'F' SEND AS 'D1' SEND AS 'D2' SEND AS 'D3' SEND AS 'D4' SEND AS 'D5' SEND AS 'A' SEND AS 'A' SEND AS 'E' SEND AS 'E' SEND AS 'FF' SEND AS 'FF' SEND AS 'F' SEND AS 'F' SEND AS '*' SEND AS '%' SEND AS 'i' SEND AS '!' SEND AS '&' SEND AS '#' SEND AS '@'

APPENDIX A STD. DEFAULTS

UPC-A --------------------- Don't Send UPC-E --------------------- Don't Send EAN-8 --------------------- Don't Send EAN-13 ------------------- Don't Send UPC-D1 ------------------- Don't Send UPC-D2 ------------------- Don't Send UPC-D3 ------------------- Don't Send UPC-D4 ------------------- Don't Send UPC-D5 ------------------- Don't Send UPC-A (2 add-on) ------ Don't Send UPC-A (5 Add-on) ------ Don't Send UPC-E (2 add-on) ------ Don't Send UPC-E (5 Add-on) ------ Don't Send EAN-8 (2 add-on) ------- Don't Send EAN-8 (5 Add-on) ------ Don't Send EAN-13 (2 add-on) ----- Don't Send EAN-13 (5 Add-on) ----- Don't Send Code 39 ------------------ Don't Send Codabar ------------------ Don't Send Ind.2 of 5 ----------------- Don't Send Std. 2 of 5---------------- Don't Send Code 93 ------------------ Don't Send Code 128 ----------------- Don't Send MSI/Plessey ------------- Don't Send Code 49 ------------------ NONE Code 16K ----------------- NONE

107

Page 114

PC KEYBOARD WEDGE Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

COMMUNICATION PARAMETERS INTERCHARACTER DELAY ----------------------------- NONE 5ms 10ms ----------------------------- 20ms 25ms 30ms ----------------------------- 40ms 45ms 50ms ----------------------------- 60ms PREFIX /SUFFIX Prefix ---------------------- SET TO NUL Suffix ---------------------- SEND AS CARRIAGE RETURN

15ms 35ms 55ms

SYMBOLOGY SELECTION

APPENDIX A STD. DEFAULTS

UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE ENABLE DISABLE DISABLE DISABLE OPTIONAL Disable

CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable

Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE

108

SP400 Programming Guide

Page 115

PC KEYBOARD WEDGE (CONT.) Disable DON'T CALCULATE Don't Send VARIABLE LENGTH

STANDARD 2 OF 5 Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- ENABLE Disable Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ Send DON'T SEND Start/Stop Character ------------------- Send DON'T SEND Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD --------------------------------------------- abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE ITALIAN CODE 39 Symbology ------------------------------- Enable DISABLE CODE 5 Symbology ------------------------------- Enable DISABLE CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- ENABLE Disable CODE 128 Symbology ------------------------------- ENABLE Disable MSI/PLESSEY Symbology ------------------------------- ENABLE Disable

R44-1020

109

APPENDIX A STD. DEFAULTS

INTERLEAVED 2 OF 5 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8

Page 116

PC KEYBOARD WEDGE GENERAL FEATURES These features can be used to customize the user interface features. AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ V ERIFICATION ----------------------------- 1 READ

2 read

3 read

Long High

4 read

DEFAULT SYMBOLOGY IDENTIFIERS

APPENDIX A STD. DEFAULTS

UPC-A ----------------------------------------------------- NONE UPC-E ----------------------------------------------------- NONE EAN-8 ----------------------------------------------------- NONE EAN-13 --------------------------------------------------- NONE UPC-D1 --------------------------------------------------- NONE UPC-D2 --------------------------------------------------- NONE UPC-D3 --------------------------------------------------- NONE UPC-D4 --------------------------------------------------- NONE UPC-D5 --------------------------------------------------- NONE UPC-A (2 add-on) -------------------------------------- NONE UPC-A (5 Add-on) -------------------------------------- NONE UPC-E (2 add-on) -------------------------------------- NONE UPC-E (5 Add-on) -------------------------------------- NONE EAN-8 (2 add-on) --------------------------------------- NONE EAN-8 (5 Add-on) -------------------------------------- NONE EAN-13 (2 add-on) ------------------------------------- NONE EAN-13 (5 Add-on) ------------------------------------- NONE Code 39 -------------------------------------------------- NONE Codabar -------------------------------------------------- NONE Ind.2 of 5 ------------------------------------------------- NONE Std. 2 of 5------------------------------------------------ NONE Code 93 -------------------------------------------------- NONE Code 128 ------------------------------------------------- NONE MSI/Plessey --------------------------------------------- NONE Code 49 -------------------------------------------------- NONE Code 16K ------------------------------------------------- NONE

110

SP400 Programming Guide

Page 117

SIX-BIT (OMRON) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE Enable DISABLE DISABLE Optional

CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE

DISABLE

INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE

R44-1020

111

APPENDIX A STD. DEFAULTS

DISABLE

Page 118

ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable

DISABLE DISABLE DISABLE DISABLE DISABLE

DISABLE

GENERAL FEATURES

APPENDIX A STD. DEFAULTS

AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ

112

2 read

3 read

Long High

4 read

SP400 Programming Guide

Page 119

SIX-BIT (FUJITSU) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE Enable DISABLE DISABLE Optional

CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE

DISABLE

INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE

R44-1020

113

APPENDIX A STD. DEFAULTS

DISABLE

Page 120

ITALIAN C ODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable

DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE

GENERAL FEATURES

APPENDIX A STD. DEFAULTS

AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ V ERIFICATION ----------------------------- 1 READ

114

2 read

3 read

Long High

4 read

SP400 Programming Guide