The text of a manual · part 13 of 13
SP400 Programming Guide, pages 121 to 128
Pages 121 to 128 of 128
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC SP-400
Page 121
SIX-BIT (FIJITSU-CLOVER) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable
DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE
DISABLE
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE
R44-1020
115
APPENDIX A STD. DEFAULTS
DISABLE
Page 122
ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable
DISABLE DISABLE DISABLE DISABLE DISABLE
DISABLE
GENERAL FEATURES
APPENDIX A STD. DEFAULTS
AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ
116
2 read
3 read
Long High
4 read
SP400 Programming Guide
Page 123
SIX-BIT (HUGIN SWEDA) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable
DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE
DISABLE
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE
R44-1020
117
APPENDIX A STD. DEFAULTS
DISABLE
Page 124
ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable
DISABLE DISABLE DISABLE DISABLE DISABLE
DISABLE
GENERAL FEATURES
APPENDIX A STD. DEFAULTS
AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ
118
2 read
3 read
Long High
4 read
SP400 Programming Guide
Page 125
MULTIDROP Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
DISABLE
DISABLE
AUDIBLE INDICATOR SETTINGS Speaker -----------------------------------ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume -----------------------------------Low MEDIUM Sounds -----------------------------------WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 2 read 3 read PERPHERIAL ID SETTING ------------------------------------ 70
R44-1020
71
72
Long High
4 read
73
119
APPENDIX A STD. DEFAULTS
GENERAL FEATURES
Page 126
APPENDIX B ADDITIONAL INFORMATION HOST PROGRAMMING Some interfaces and host systems include the ability to configure the scanner by sending commands to the scanner.
CREATING MULTIFUNCTION LABELS The term, multifunction label, describes a programming label that contains multiple programming features in one programming label. These labels can be created with label making software that supports Code 128.
NEED MORE INFORMATION If you require more information about using your host system to change the scanner's programmable features or detailed instructions about creating multifunction labels, contact your local dealer or distributor or call (in the U.S. or Canada) PSC Technical Support at 1-800-547-2507.
APPENDIX B APPENDIX C ADDITIONAL INFO TEST BARCODES
120
SP400 Programming Guide
Page 127
APPENDIX C SAMPLE BARCODES CODE 128 Code 128.Test
CODE 39 Code 39.Test
INTERLEAVED 2 OF 5 0123456789
CODABAR
CODE 93 Code 93.Test
UPC-A
0 00112 23344
R44-1020
121
APPENDIX C APPENDIX B TEST BARCODES ADDITIONAL INFO
$99.95
Page 128
49 0
UPC-A W/2 DIGIT ADD-ON
60992 01118 69000
UPC-A W/ 5 DIGIT ADD-ON
0 08029 51041
UPC-E
0 998875
EAN-8 0021 0126
APPENDIX B APPENDIX C ADDITIONAL INFO TEST BARCODES
EAN-13 1 101234 567891
122
SP400 Programming Guide