The text of a manual · part 11 of 13

SP400 Programming Guide, pages 101 to 110

Pages 101 to 110 of 128

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC SP-400

Page 101

OCIA (PSC) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE Enable DISABLE DISABLE Optional

CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE

STANDARD 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable

R44-1020

DISABLE

DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH

DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH

DISABLE DISABLE

95

APPENDIX A STD. DEFAULTS

INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8

DISABLE

Page 102

CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- Enable DISABLE CODE 128 Symbology ------------------------------- Enable

DISABLE

MSI/PLESSEY Symbology ------------------------------- Enable

DISABLE

APPENDIX A STD. DEFAULTS

GENERAL FEATURES . AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ

96

2 read

3 read

Long High

4 read

SP400 Programming Guide

Page 103

OCIA NCR SHORT FORMAT (EIGHT BIT) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology -------------------------------ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable

Disable DISABLE Enable DISABLE DISABLE

DISABLE

GENERAL FEATURES .

R EAD VERIFICATION ----------------------------- 1 READ

R44-1020

2 read

3 read

Long High

4 read

97

APPENDIX A STD. DEFAULTS

A UDIBLE INDICATOR SETTINGS Speaker -----------------------------------ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ----------------------------------SHORT Medium Volume -----------------------------------Low MEDIUM Sounds -----------------------------------WHEN LABEL IS READ After data sent to host

Page 104

OCIA NCR LONG FORMAT (NINE BIT) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION

APPENDIX A STD. DEFAULTS

UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODE 128 Symbology ------------------------------- Enable ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable

Disable DISABLE ENABLE DISABLE

DISABLE

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH

DISABLE DISABLE DISABLE DISABLE DISABLE

GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker -----------------------------------ENABLE Disable Good Read Tone ------------------------ Tone A Tone B --------------------------------------------- TONE C Tone D Duration ---------------------------------- SHORT Medium Volume -----------------------------------Low MEDIUM Sounds -----------------------------------WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 2 read 3 read

98

Long High

4 read

SP400 Programming Guide

Page 105

OCIA (SNI) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE Enable DISABLE DISABLE Optional

CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE

R44-1020

DISABLE

DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH

DISABLE DISABLE DISABLE DISABLE

99

APPENDIX A STD. DEFAULTS

INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable

DISABLE

Page 106

C ODABAR Symbology -------------------------------Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match -----------------------Enable DISABLE Label Format ----------------------------Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check -------------------------------Enable DISABLE C ODE 93 Symbology -------------------------------Enable

DISABLE

C ODE 128 Symbology -------------------------------Enable

DISABLE

GENERAL FEATURES

APPENDIX A STD. DEFAULTS

A UDIBLE INDICATOR SETTINGS Speaker -----------------------------------ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ----------------------------------SHORT Medium Long Volume -----------------------------------Low MEDIUM High Sounds -----------------------------------When label is read AFTER DATA SENT TO HOST R EAD VERIFICATION ----------------------------- 1 READ 2 read 3 read 4 read

100

SP400 Programming Guide

Page 107

OCIA (METROLOGIC) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required

Disable DISABLE Enable DISABLE DISABLE Optional

CODE 39 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- SEND Read One Character Label ------------ Enable

DISABLE DON'T CALCULATE Don't Send Don't Send DISABLE

DISABLE

INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE

R44-1020

101

APPENDIX A STD. DEFAULTS

DISABLE

Page 108

ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- Enable CODE 128 Symbology ------------------------------- Enable

DISABLE DISABLE DISABLE DISABLE DISABLE

DISABLE

GENERAL FEATURES

APPENDIX A STD. DEFAULTS

AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ

102

2 read

3 read

Long High

4 read

SP400 Programming Guide

Page 109

WAND EMULATION Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these setting have not been changed in a previous programming session.

INTERFACE SPECIFIC SETTINGS The following settings are unique to Wand Emulation. POLARITY ----------------------------- SPACE LOW, BAR HIGH ----------------------------- Space High, Bar Low SIGNAL SPEED ----------------------------- LOW (660 µs) High (330µs) DATA FORMAT ----------------------------- NORMAL Send as Code 39 IDLE STATE ----------------------------- LOW High

SYMBOLOGY SELECTION

R44-1020

Disable DISABLE Enable DISABLE DISABLE Optional

DISABLE

DISABLE

Disable DON'T CALCULATE Don't Send DISABLE Disable DON'T CALCULATE Don't Send VARIABLE LENGTH

Disable DON'T CALCULATE

103

APPENDIX A STD. DEFAULTS

UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Read One Character Label ------------ Enable INTERLEAVED 2 OF 5 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 STANDARD 2 OF 5 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate

Page 110

Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8

Don't Send VARIABLE LENGTH

APPENDIX A STD. DEFAULTS

CODABAR Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Match ----------------------- Enable Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable CODE 93 Symbology ------------------------------- ENABLE CODE 128 Symbology ------------------------------- ENABLE MSI/PLESSEY Symbology ------------------------------- ENABLE SEND AS CODE 391 Symbology ------------------------------- Enable

Disable DON'T CALCULATE Don't Send DISABLE VARIABLE LENGTH

DISABLE DISABLE DISABLE DISABLE DISABLE Disable Disable Disable DISABLE

GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 2 read 3 read 1

104

Long High

4 read

Converts UPC-D, UPC/EAN Add-ons, Code 93, I 2 of 5, and MSI/Plessey barcode data into Code 39 format before sending data to host.

SP400 Programming Guide