Page 91
APPENDIX A STANDARD FACTORY SETTINGS TABLE OF CONTENTS IBM 468x Port 5B ----------------------------------------------------------
87
468x/9x Port 9B -------------------------------------------------------
89
468x Port 17 ----------------------------------------------------------
91
469x Port E ------------------------------------------------------------
93
OCIA PSC -------------------------------------------------------------------NCR Eight Bit (Short Format)
95
---------------------------------------- 97
SNI ---------------------------------------------------------------------
99
Metrologic ------------------------------------------------------------
101
APPENDIX A STD. DEFAULTS
NCR Nine Bit (Long Format) ----------------------------------------- 98
Wand Emulation ------------------------------------------------------------ 103 RS-232 ----------------------------------------------------------------------- 105 PC Keyboard Wedge ------------------------------------------------------- 108 Six-Bit Omron ----------------------------------------------------------------
111
Fujitsu -----------------------------------------------------------------
113
Fijitsu-Clover ---------------------------------------------------------
115
Hugin-Sweda ---------------------------------------------------------
117
Multidrop -------------------------------------------------------------------- 1 1 9
R44-1020
85
Page 92
This appendix includes detailed listings of the standard factory settings for each interface. Unless your scanner had custom interface or operation settings loaded at the factory, these tables show how your scanner is set up for operation. To check if your scanner includes these standard defaults, check the configuration code by checking the model number label affixed to the scanner's interface cable. Configuration Code, 00 indicates that the scanner has the PSC standard factory settings installed which corresponds to the default listing shown with each interface. Any number other than 00 indicates that a special configuration file replaces the standard configuration. If anything other than 00 is present, the tables in this appendix that show the factory settings for each interface do not apply to your scanner's settings.
APPENDIX A STD. DEFAULTS
Configuration Code MODEL: 180901-501000 SERIAL NO: xxxxxxxxx MANUFACTURED:
November 18, 1992
86
SP400 Programming Guide
Page 93
IBM (PORT 5B) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these settings have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology -------------------------------ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ----------------------------------Required
Disable DISABLE Enable DISABLE DISABLE Optional
C ODE 39 Symbology -------------------------------ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable
Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE
S TANDARD 2 OF 5 Symbology -------------------------------Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ----------------------------Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology -------------------------------Enable C ODE 5 Symbology -------------------------------Enable
R44-1020
DISABLE
Disable DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DISABLE
87
APPENDIX A STD. DEFAULTS
INTERLEAVED 2 OF 5 Symbology -------------------------------ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ----------------------------Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8
DISABLE
Page 94
CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE
APPENDIX A STD. DEFAULTS
CODE 93 Symbology ------------------------------- Enable
DISABLE
CODE 128 Symbology ------------------------------- Enable
DISABLE
MSI/PLESSEY Symbology ------------------------------- Enable
DISABLE
SEND AS CODE 391 Symbology ------------------------------- ENABLE
Disable
GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 1
88
2 read
3 read
Long High
4 read
Converts UPC-D, UPC/EAN Add-ons, Code 128, Code 93, Standard 2 of 5, Codabar and MSI/Plessey barcode data into Code 39 format before sending data to host.
SP400 Programming Guide
Page 95
IBM (PORT 9B) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these settings have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable
Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE
STANDARD 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable
R44-1020
DISABLE
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DISABLE
89
APPENDIX A STD. DEFAULTS
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8
DISABLE
Page 96
CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- Enable DISABLE
APPENDIX A STD. DEFAULTS
CODE 128 Symbology ------------------------------- Enable
DISABLE
MSI/PLESSEY Symbology ------------------------------- Enable
DISABLE
SEND AS CODE 391 Symbology ------------------------------- ENABLE
Disable
GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 1
90
2 read
3 read
Long High
4 read
Converts UPC-D, UPC/EAN Add-ons, Code 128, Code 93, Standard 2 of 5, Codabar and MSI/Plessey barcode data into Code 39 format before sending data to host.
SP400 Programming Guide
Page 97
IBM (PORT 17) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these settings have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable
Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE
STANDARD 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable
R44-1020
DISABLE
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DISABLE
91
APPENDIX A STD. DEFAULTS
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8
DISABLE
Page 98
CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- Enable DISABLE
APPENDIX A STD. DEFAULTS
CODE 128 Symbology ------------------------------- Enable
DISABLE
MSI/PLESSEY Symbology ------------------------------- Enable
DISABLE
SEND AS CODE 391 Symbology ------------------------------- ENABLE
Disable
GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 1
92
2 read
3 read
Long High
4 read
Converts UPC-D, UPC/EAN Add-ons, Code 128, Code 93, Standard 2 of 5, Codabar and MSI/Plessey barcode data into Code 39 format before sending data to host.
SP400 Programming Guide
Page 99
IBM (PORT E) Text formatted in BOLD type indicates the standard factory configuration setting. These settings are valid if the configuration code indicates standard PSC factory settings and these settings have not been changed in a previous programming session.
SYMBOLOGY SELECTION UPC/EAN Symbology ------------------------------- ENABLE Expand UPC-A to EAN-13 ------------- Enable Expand UPC-E to UPC-A -------------Expand UPC-E to EAN-13 ------------- Enable UPC-D ------------------------------------ Enable Add-Ons ---------------------------------- Required
Disable DISABLE Enable DISABLE DISABLE Optional
CODE 39 Symbology ------------------------------- ENABLE Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Start/Stop Character ------------------- Send Read One Character Label ------------ Enable
Disable DON'T CALCULATE Don't Send DON'T SEND DISABLE
STANDARD 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 ITALIAN CODE 39 Symbology ------------------------------- Enable CODE 5 Symbology ------------------------------- Enable
R44-1020
DISABLE
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DON'T CALCULATE Don't Send VARIABLE LENGTH
DISABLE DISABLE
93
APPENDIX A STD. DEFAULTS
INTERLEAVED 2 OF 5 Symbology ------------------------------- Enable Check Digit ------------------------------ Calculate Check Digit ------------------------------ SEND Label Format ---------------------------- Fixed Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8
DISABLE
Page 100
CODE 49 (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODE 16K (SP400HD MODELS ONLY) Symbology ------------------------------- Enable DISABLE CODABAR Symbology ------------------------------- Enable DISABLE Check Digit ------------------------------ Calculate DON'T CALCULATE Check Digit ------------------------------ SEND Don't Send Start/Stop Character ------------------- SEND Don't Send Start/Stop Format ---------------------- ABCD/TN*E ABCD/ABCD abcd/tn*e abcd/abcd Start/Stop Match ----------------------- Enable DISABLE Label Format ---------------------------- Fixed VARIABLE LENGTH Set 1st Fixed Length ------------------- 14 Set 2nd Fixed Length ------------------ 8 Gap Check ------------------------------- Enable DISABLE CODE 93 Symbology ------------------------------- Enable DISABLE
APPENDIX A STD. DEFAULTS
CODE 128 Symbology ------------------------------- Enable
DISABLE
MSI/PLESSEY Symbology ------------------------------- Enable
DISABLE
SEND AS CODE 391 Symbology ------------------------------- ENABLE
Disable
GENERAL FEATURES AUDIBLE INDICATOR SETTINGS Speaker ----------------------------------- ENABLE Disable Good Read Tone ------------------------ Tone A Tone B TONE C Tone D Duration ---------------------------------- SHORT Medium Volume ----------------------------------- Low MEDIUM Sounds ----------------------------------- WHEN LABEL IS READ After data sent to host READ VERIFICATION ----------------------------- 1 READ 1
94
2 read
3 read
Long High
4 read
Converts UPC-D, UPC/EAN Add-ons, Code 128, Code 93, Standard 2 of 5, Codabar and MSI/Plessey barcode data into Code 39 format before sending data to host.
SP400 Programming Guide