The text of a manual · part 3 of 4
Handheld Laser Scanners Keyboard Wedge Interface Programming (SP400 and QuickScan 6000/6000 Plus), pages 19 to 27
Pages 19 to 27 of 36
The original document is the PDF (314 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS-6000, Wasp QS-6000 and Datalogic QS-6000
Page 19
SETTING SYMBOLOGY SPECIFIC LABEL IDENTIFIERS (LABEL I.D.) CONTINUED 4.
Scan the label from the following two pages representing the symbology whose label identifier you wish to modify. In our example (previous page), we would scan the 'UPCA' symbology label.
5.
Identify and scan the characters from pages 15-16 that correspond to the Hex Values. The hex values from the ASCII chart that correspond to 'A1' from our example are as follows: 41hex = 'A', and 31 hex = '1'. Thus, we would scan digit programming labels in this order: 4, 1, 3, 1.
6.
Scan the END label. In our example (previous page), you have changed the default label identifier prefix for UPC-A from 'A' to 'A1'.
SET
------------------------------------DISABLE LABEL I.D. CONTROL ---TRANSMIT LABEL I.D. AS PREFIX TRANSMIT LABEL I.D. AS SUFFIX -
R44-1542
15
Page 20
LABEL I.D. SYMBOLOGY SELECTION UPC-A ---------------------UPC-A W/2 DIGIT ADD-ON ---UPC-A W/5 DIGIT ADD-ON ----
SET SYMBOLOGY SPECIFIC LABEL IDENTIFIER FOR:
UPC-A W/C128 ADD -ON ----UPC-E ---------------------UPC-E W/2 DIGIT ADD-ON ---UPC-E W/5 DIGIT ADD-ON ---UPC-E W/C128 ADD-ON ----EAN-8 ---------------------EAN-8 W /2 DIGIT ADD -ON ----EAN-8 W /5 DIGIT ADD -ON ----EAN-8 W /C128 ADD-ON ----EAN-13 ---------------------
16
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 21
LABEL I.D. SYMBOLOGY SELECTION CONTINUED EAN-13 W/2 DIGIT ADD-ON ---
SET SYMBOLOGY SPECIFIC LABEL IDENTIFIER FOR:
EAN-13 W/5 DIGIT ADD-ON --EAN-13 W/C128 ADD-ON --CODE 39 --------------------CODABAR ---------------------I NTERLEAVED 2 OF 5 ----------STANDARD 2 OF 5 ------------CODE 93 --------------------CODE 128 -------------------MSI/PLESSEY ---------------END
R44-1542
-------------------------------------
17
Page 22
HOW TO SET SINGLE CHARACTER LABEL I.D. If you only want a single character identifier, follow this modified procedure for setting label identifier. 1.
Look at the ASCII chart shown on the inside back cover of this manual and identify the ASCII character and the corresponding Hex Code for the ASCII character you will use as the symbology specific identifier.
2.
Scan the SET label on page 15.
3.
Scan the appropriate label for setting either TRANSMIT LABEL I.D. AS PREFIX or SUFFIX.
4.
Scan the label identifier label from pages 16-17 for the symbology identifier that you are going to change. As an example, assume that you want to change the label identifier for EAN-8 from the default setting FF to the ASCII value 8. Scan the Set Symbology Specific Label Identifier bar code for EAN-8.
5.
Identify the hex value that correspond to the ASCII character. In this example '8' equals 38 hex. Simply follow the hex value for '8' (38 hex) with the One Character Only label. This tells the scanner that '8' is a single character label identifier.
6.
Scan the bar code values. For the example in step five, scan 3, 8, One Character Only on the following two pages.
NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 7.
Scan the END label. You have changed the default label identifier for EAN-8 from 'FF' to '8'.
18
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 23
DISABLING LABEL I.D. FOR A SPECIFIC SYMBOLOGY This procedure is the same as setting a single character symbology identifier, except you should scan two zeros and the One Character Only labels before scanning the END label.
SYMBOLOGY SPECIFIC LABEL IDENTIFIERS CHARACTERS Use the labels on this page to change or modify symbology identifiers.
0 ----------------------------1 -----------------------------
SETTING LABEL I.D. CHARACTERS
2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 -----------------------------
R44-1542
19
Page 24
SYMBOLOGY SPECIFIC LABEL IDENTIFIERS CHARACTERS - CONTINUED A -----------------------------
SETTING LABEL I.D. CHARACTERS
B ----------------------------C ----------------------------D ---------------------------E ----------------------------F ----------------------------ONE CHARACTER ONLY --------END
20
-------------------------------------
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 25
UNIVERSAL SYMBOLOGY SELECTION To set the scanner to read all symbologies, scan the ENABLE ALL SYMBOLOGIES bar code below. NOTE
DO NOT scan a SET/END bar code when programming universal symbology features. Programming mode is automatically entered and exited when one of the two special bar codes below are scanned.
ENABLE ALL SYMBOLOGIES
DISABLE ALL SYMBOLOGIES1
1
Code 128 is always active for the purpose of reading programming bar code labels, however, the scanner does not transmit data to the host when in Programming Mode.
R44-1542
21
Page 26
SYMBOLOGY SELECTION The bar code programming labels on the following pages allow you to enable or disable individual symbologies.
SET
------------------------------------ENABLE UPC/EAN ----------DISABLE UPC/EAN ----------
SYMBOLOGY SELECTION
ENABLE CODE 39 -------------DISABLE CODE 39 ------------ENABLE PHARMAC ODE2 39 ----DISABLE PHARMAC ODE 39 ----ENABLE INTERLEAVED 2 OF 5 --DISABLE INTERLEAVED 2 OF 5 --ENABLE STANDARD 2 OF 5 -----
2
22
Code 39 must first be enabled for the scanner to read PharmaCode 39 labels.
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 27
DISABLE STANDARD 2 OF 5 ---ENABLE IATA3 ---------------DISABLE IATA ---------------ENABLE CODABAR -------------SYMBOLOGY SELECTION
DISABLE CODABAR ------------ENABLE CODE 93 -------------DISABLE CODE 93 ------------ENABLE CODE 128 -----------DISABLE CODE 1284 ---------ENABLE MSI/PLESSEY --------DISABLE MSI/PLESSEY --------
END
3 4
-------------------------------------
Standard 2 of 5 must first be enabled before IATA can be enabled. Code 128 is always active for the purpose of reading programming bar code labels. Scanning the DISABLE ALL SYMBOLOGIES or the DISABLE CODE 128 labels disables Code 128 transmission to the host (disables decoding of all C128 non-programming labels).
R44-1542