Page 28
INTERLEAVED 2 OF 5 The Interleaved 2 of 5 symbology has the following programmable features: Check Digit, calculate the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit. You may also choose to transmit or not transmit the Check Digit independent of whether the Check Digit is calculated by the scanner. Transmit Check Digit will have no effect unless the Compute Check Digit feature is enabled. If you choose Don't Compute Check Digit, the scanner sends the Check Digit encoded in the bar code without verifying its accuracy. If you choose both Compute Check Digit and Don't Transmit Check Digit, the scanner will remove the Check Digit's contents before sending the bar code data to the host. Variable Length, If you select variable length, the scanner will recognize labels with an even number of characters between the minimum length set (see the following section) and 501 characters.
SET
-------------------------------------
CHECK DIGIT
DON'T COMPUTE ---------------COMPUTE ---------------------DON'T TRANSMIT ---------------
VARIABLE LENGTH L ABELS
TRANSMIT ---------------------
END
24
ENABLE -----------------------DISABLE ----------------------------------------------------------SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 29
SETTING INTERLEAVED 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable to fixed length labels (by disabling variable lengths on the previous page), the default fixed label lengths are 14 characters and 8 characters. Follow the steps below to change these defaults. All fixed length settings for Interleaved 2 of 5 must be an even number. SET FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the ENABLE FIRST FIXED barcode.
SETTING FIXED LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 06, 08). 4.
Set the first fixed label length by scanning the correct digits from the next two pages. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the NO SECOND FIXED LENGTH below and skip to step seven.
5.
Scan the SET SECOND FIXED label.
6.
Set the second fixed label length by scanning the correct digits from this page.
7.
Scan the END label to complete the procedure.
SETTING MINIMUM LABEL LENGTH 1. Identify the minimum length setting you want to make. The selectable range is 04 to 501 characters. 2.
Scan the SET label.
3.
Scan the SET MINIMUM LABEL LENGTH barcode.
If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 06, 08). 4.
Set the minimum label length by scanning the correct digits from the next two pages
5.
Scan the END label.
1
The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.
R44-1542
25
Page 30
SET
------------------------------------SET FIRST FIXED LENGTH ------
INTERLEAVED 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS
SET SECOND FIXED LENGTH ---NO SECOND FIXED LENGTH ----SET MINIMUM LABEL LENGTH --0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------6 ----------------------------8 ----------------------------END
26
-------------------------------------
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 31
CODABAR CHECK DIGIT & VARIABLE LENGTH These programming labels determine whether you compute and send the check digit contents and enables variable length.
SET
-------------------------------------
CHECK DIGIT
DON'T COMPUTE ---------------COMPUTE ---------------------DON'T TRANSMIT ---------------
GAP CHECK
VARIABLE LENGTH L ABELS
TRANSMIT ---------------------
END
R44-1542
ENABLE -----------------------DISABLE ----------------------ENABLE -----------------------DISABLE -----------------------------------------------------------
27
Page 32
CODABAR FIXED LENGTH Most scanners shipped from the factory are set to read variable length labels for Codabar. If you switch from variable to fixed length labels (by disabling variable lengths on the previous page), the factory set fixed label lengths are 14 and 08. Follow the steps below to change these defaults. ENABLE FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the SET FIRST FIXED LENGTH label.
SETTING LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit (02, ...09). 4.
Set the first fixed length label by scanning the correct digits from the next page. The selectable range is from 03 to 501. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length, scan the NO SECOND FIXED LENGTH label below and skip to step seven.
SET
-------------------------------------
CODABAR
SET FIRST FIXED LENGTH -----SET SECOND FIXED LENGTH ---NO SECOND FIXED LENGTH -----
1
28
The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 33
5.
Scan the SET SECOND FIXED LENGTH label.
6.
Set the second fixed label length by scanning the correct digits from this page. The selectable range is from 03 to 501.
7.
Scan the END label to complete the procedure.
0 ----------------------------1 ----------------------------2 -----------------------------
CODABAR SET FIXED LENGTHS
3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 -----------------------------
END
1
-------------------------------------
The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.
R44-1542
29
Page 34
MSI/PLESSEY CHECK DIGIT MSI/Plessey Check Digit options include: Check Digit Calculation, calculate the Check Digit to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Transmit Check Digit, enable or disable transmission of MSI/Plessey Check Digit(s). Number of Check Digits, specify either one or two Check Digits.
SET
------------------------------------CALCULATE CHECK DIGIT -------
MSI/PLESSEY CHECK DIGIT SELECTIONS
DON'T CALCULATE CHECK DIGIT TRANSMIT CHECK D IGIT -------DON'T TRANSMIT CHECK DIGIT ONE CHECK D IGIT ------------TWO CHECK DIGITS -----------END
30
-------------------------------------
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 35
ASCII CHARACTER SET The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters. ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE nul soh stx etx eot enq ack bel bs ht lf vt ff cr so si dle dc1 dc2 dc3 dc4 nak syn etb can em sub esc fs gs rs us
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F sp ! " # $ % & ' ( ) * + ' . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ del
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Page 36
Asia Pacific
Italy
PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Telefax: [852]-2-521-0291
PSC S.r.l. Vimercate (MI), Italy Telephone: 039/62903.1 Telefax: 039/6859496
Australia
Japan
PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61]0(2)9878 8999 Telefax: [61]0(2)9878 8688
PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Telefax: 81 (0)3 3491 6656
France
Latin America
PSC Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Telefax : [33].1.64 46.72.44
PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Telefax: (305) 539-0206
Germany
United Kingdom
PSC GmbH Darmstadt, Germany Telephone: + 49 (0) 61 51/93 58 - 0 Telefax: + 49 (0) 61 51/93 58 58
PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Telefax: 44 (0) 1923 809 505
Corporate Headquarters www.pscnet.com
675 Basket Road Webster, NY 14580-9787 Telephone: (716) 265-1600 Toll Free: (800) 828-6489 Telefax: (716) 265-6400
PSC Scanning, Inc. 959 Terry Street Eugene, OR 97402-9150 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Telefax: (541) 686-1702
PRINTED WITH
SOY INK
Printed on recycled paper
© 1998 PSC INC.
R44-1542 (Rev. E)
Printed in USA 10/98