Page 10
PC KEYBOARD WEDGE – CONNECT TO A LAPTOP/NO KEYBOARD ATTACHED If no keyboard is attached, the scanner must provide the acknowledge signal to the PC. In this case, enable the "Laptop/No External Keyboard" mode. If a keyboard is attached, enable "Keyboard Attached". Laptop (integrated keyboard), Scan the "Laptop/No External Keyboard" label below when the scanner is connected to a laptop computer or when the scanner is operated with no external keyboard attached. PC (external keyboard), If you move the scanner to a standard PC, change the setting to "Keyboard Attached". Send Control Characters, When this feature is disabled, all ASCII characters except NUL (00h) are transmitted. Enabling this feature limits transmission of ASCII characters to the following: •
Only ASCII characters between 20h..127h, plus… - Carriage Return (CR=0Dh) - BackSpace (BS=08h) - Right Tab (HT=09h) - Left Tab (0Bh) - Esc (1Bh)
SEND CONTROL CHARACTERS
CONNECT TO LAPTOP OR PC
SET
END
6
------------------------------------LAPTOP/NO EXTERNAL KEYBOARD KEYBOARD ATTACHED ----------ENABLE -----------------------DISABLE -----------------------------------------------------------
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 11
PC KEYBOARD WEDGE - INTERCHARACTER DELAY Intercharacter Delay refers to the pause between each character before it is sent to the host. A time delay controls the flow of data from the scanner. Use these labels to enable/disable a 20 mSec Intercharacter Delay if needed.
INTERCHARACTER DELAY
SET --------------------------------
= NONE (DEFAULT) -----------= 20 MILLISECONDS ------------
END --------------------------------
R44-1542
7
Page 12
CAPS LOCK (QUICKSCAN 6000 PLUS ONLY) Three caps lock settings are available for the QuickScan 6000 Plus scanner. These are:
8
Caps Lock Off, to send character data (to the host)in normal format.
•
Caps Lock On, to send character data (to the host) in reverse case: (a…z) = (A…Z) (A…Z) = (a…z) Use this feature if your caps lock is on.
•
Caps Lock = Shift-Lock, to send character data (to the host) in shifted case. Use this feature if your shift lock is on. For use with interface type G (122-keyboard) ONLY.
SET
-------------------------------------
CAPS LOCK OPTIONS
•
CAPS LOCK OFF --------------
END
-------------------------------------
CAPS LOCK ON --------------CAPS LOCK = SHIFT -LOCK -----
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 13
COUNTRY MODE (QUICKSCAN 6000 PLUS ONLY) The following country/languages can be selected for the QuickScan 6000 Plus scanner: • • • •
USA Belgium Britain Denmark
SET
• • • •
France Germany Italy Norway
• • • •
Portugal • Japanese 106-Key Spain Sweden Switzerland
------------------------------------USA ------------------------BELGIUM ----------------------
COUNTRY MODE
BRITAIN ----------------------DENMARK --------------------FRANCE ----------------------GERMANY --------------------I TALY ------------------------NORWAY ---------------------PORTUGAL ---------------------
R44-1542
9
Page 14
COUNTRY MODE (QUICKSCAN 6000 PLUS ONLY) - CONTINUED
COUNTRY MODE
SPAIN ------------------------SWEDEN ----------------------SWITZERLAND -----------------JAPANESE 106-KEY ----------END
10
-------------------------------------
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 15
SETTING PREFIX AND/OR SUFFIX CHARACTERS (PREAMBLE/POSTAMBLE) To set the prefix or suffix, identify your specific system requirements for modification of the settings, then follow these steps: 1.
Look at the ASCII chart on the inside back cover of this manual and identify the ASCII character and the corresponding Hex Code you will use as the prefix or suffix.
2.
Scan the SET label below.
3.
Scan either the SET PREFIX or SET SUFFIX label.
4.
Scan the Hex Code for that character. (e.g. 03, 8F, ...FF) NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 5.
If setting a single character, scan the ONE CHARACTER ONLY label on the second page following.
6.
Scan the END label.
You have set the prefix or suffix.
SET
------------------------------------SET PREFIX ------------------SET SUFFIX -------------------
R44-1542
11
Page 16
SETTING PREFIX AND/OR SUFFIX CHARACTERS NOTE
You must scan the SET label and either the SET PREFIX or SET SUFFIX label before using the labels on this page.
0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 -----------------------------
12
SP400/QuickScan 6000/6000 Plus Keyboard Wedge I/F Prog
Page 17
SETTING PREFIX AND/OR SUFFIX CHARACTERS - CONTINUED NOTE
You must scan the SET label and either the SET PREFIX or SET SUFFIX label before using the labels on this page.
A ----------------------------B ----------------------------C ----------------------------D ---------------------------E ----------------------------F ----------------------------ONE CHARACTER ONLY --------END
R44-1542
-------------------------------------
13
Page 18
SETTING SYMBOLOGY SPECIFIC LABEL IDENTIFIERS (LABEL I.D.) Symbology-specific label identifiers comprise one or two ASCII characters that can precede or follow bar code label data as it is transmitted to the host. The host uses these characters as a means of distinguishing between symbologies. Industry standards have been established for symbology-specific label identifiers, and are listed in the table below. Most scanners will have factory default identifiers preset to these standards. UPC-A ------------------------ 'A' UPC-E ------------------------ 'E' EAN-8 ----------------------- 'FF' EAN-13 ----------------------- 'F' UPC-A (2 add-on) --------- 'A' UPC-A (5 Add-on) --------- 'A' UPC-A (8 Add-on) ---------- 'A' UPC-E (2 add-on) --------- 'E' UPC-E (5 Add-on) --------- 'E' UPC-E (8 Add-on) ---------- 'E' EAN-8 (2 add-on) --------- 'FF'
EAN-8 (5 Add-on) --------- 'FF' EAN-8 (8 Add-on) ---------- 'FF' EAN-13 (2 add-on) -------- 'F' EAN-13 (5 Add-on) -------- 'F' EAN-13 (8 Add-on) --------- 'F' Code 39 ---------------------- '*' Codabar --------------------- '%' Interleaved.2 of 5 ----------- 'i' Code 93 ---------------------- '&' Code 128 -------------------- '#' MSI/Plessey ---------------- '@'
TABLE 1. INDUSTRY STANDARD LABEL IDENTIFIERS (ALL ARE PREFIXES) To set symbology-specific label identifiers: 1.
Look at the ASCII chart on the inside back cover and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as identifiers. You will also need to determine whether the character(s) will need to be sent as a prefix or a suffix. For example: You need to change the label identifier prefix for UPC-A to 'A1'.
2.
Scan the SET label below.
3.
Scan either the TRANSMIT LABEL I.D. AS PREFIX or TRANSMIT LABEL I.D. AS SUFFIX, depending on your requirements. For our example, the 'transmit as prefix' label would be scanned.
14