The text of a manual · part 3 of 5
LazerData 11000 Series Bar Code Scanner Installation Manual, pages 21 to 30
Pages 21 to 30 of 48
The original document is the PDF (375 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 11000 and Datalogic 11000
Page 21
LazerData® 11000 Scanner
Installation Manual
RS485-nonpolled interface The RS485-nonpolled interface is a Full Duplex interface. The nonpolled configuration is used for point-to-point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The following pins of the 25-pin connector are used for RS485-nonpolled communications: 25-Pin 2 4 3 5 7
Name TX485+ TX485RX485+ RX485SGND
11000 scanner 25-pin
Function RS485 output (+) RS485 output (-) RS485 input (+) RS485 input (-) Signal Ground
USER INTERFACE 2
TX485+
4
TX485-
3
RX485+
5
RX485-
7
SGND
RX485
TX485
SGND
Figure 2.8 - RS485-nonpolled connections
2.8 - Installation
Page 22
LazerData® 11000 Scanner
Installation Manual
RS485-polled interface The RS485-polled interface is a Half Duplex (3 wires + shield) interface. The polled configuration can be used for Multidrop connections with a Multiplexer, or it can be used for a master-slave layout (see section 2.6.1). The following pins of the 25-pin connector are used for RS485-polled communications: 25-Pin 2 4 7
Name TX485+ TX485SGND
11000 scanner 25-pin
Function RS485 input/output (+) RS485 input/output (-) Signal Ground
MULTIPLEXER 2
TX485+
4
TX485-
7
SGND
+ RTX485 - RTX485 RS485REF
Figure 2.9 - RS485-polled connections
This interface is forced by software when the protocol selected is MUX32 protocol. For this interface type, the Multidrop address must also be set via serial channel by the LDHOST utility or by ESC sequences.
Installation - 2.9
Page 23
LazerData® 11000 Scanner
Installation Manual
The figure below shows a multidrop configuration with the LazerData® 11000 Scanner connected to a Multiplexer. 120 Ohm max. 2 m. 6.6 ft.
11000 scanner 1
#x (up to 31)
11000 scanner 1
#1
11000 scanner CHASSIS
1
#0
2 4 7
2 4 7 2 4 7 max. 1,200 m. 1,312 yds.
TX485+ TX485SGND three wires + shield +RTX485
MULTIPLEXER
-RTX485 RS485REF SHIELD
120 Ohm
Figure 2.10 - LazerData® 11000 Scanner Multidrop connection to a Multiplexer
2.10 - Installation
Page 24
LazerData® 11000 Scanner
Installation Manual
20-mA current loop interface The LazerData® 11000 Scanner only supports passive type current loop connections. The following pins of the 25-pin connector are used: 25-Pin 5 3 4 2
Name CLINCLIN+ CLOUTCLOUT+
11000 scanner 25-pin
Function Current Loop Input (-) Current Loop Input (+) Current Loop Output (-) Current Loop Output (+)
USER INTERFACE 5
C.L. IN-
3
C.L. IN+
4
C.L. OUT-
2
C.L. OUT+
I = 20-mA
I = 20-mA max. 300 m. 984 ft.
Figure 2.11 - 20-mA C.L. connections
Installation - 2.11
Page 25
LazerData® 11000 Scanner
Installation Manual
2.4.3 Auxiliary RS232 interface The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular operating modes such as LOCAL ECHO can be defined using the LDHOST utility program or "Host Mode" programming provided on diskette. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: 25-Pin 20 21 23 24 7
Name RXAUX TXAUX CTSAUX RTSAUX SGND
11000 scanner 25-pin
Function Auxiliary input Auxiliary output Auxiliary handshake Auxiliary handshake Signal Ground
USER INTERFACE
20 RXAUX
TXD
21 TXAUX RXD 23 CTSAUX 24 RTSAUX 7
SGND
DTR DCD SGND
RTS/CTS HARDWARE HANDSHAKING
Figure 2.12 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the scanner activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.
2.12 - Installation
Page 26
LazerData® 11000 Scanner
Installation Manual
2.4.4 Inputs The inputs available on the connector supplied with the scanner are the pins relative to the code presence sensor, as indicated below: 9-Pin 8 9
25-Pin 18 19
Name PS+ PS-
Function Presence sensor (input +) Presence sensor (input -)
d
The inputs indicated are used to connect the code presence sensor, which tells the scanner to scan for a code. The yellow LED (Figure A., ) is on during the active phase of the PS signal indicating that decoding can take place. This input is optocoupled and can be driven by both an NPN (neg.-pos.-neg.) or PNP (pos.-neg.-pos.) type command. The connections are indicated in the following diagrams: Vext 30 VDC max.
11000 scanner 9-pin PS+ PS-
11000 scanner 25-pin 8 9
PRESENCE SENSOR
+ 5V 18
PS+
19
PS- or
V
Signal
Figure 2.13 - Input NPN command using external power
Installation - 2.13
Page 27
LazerData® 11000 Scanner
Installation Manual
11000 scanner 9-pin 7
VS PS+
11000 scanner 25-pin
PRESENCE SENSOR 9
VS
18
PS+
19
PS-
25
GND
V
+ 5V 8 9
PS- or
5 GND
Signal Ground
Figure 2.14 - Input NPN command using 11000 Scanner power Vext 30 VDC max.
11000 scanner 25-pin
11000 scanner 9-pin
PRESENCE SENSOR V
PS+ PS-
+ 5V
8 9
18
PS+
19
PS-
Signal or Ground
Figure 2.15 - Input PNP command using external power 11000 scanner 9-pin VS PS+ PS-
11000 scanner 25-pin
7
PRESENCE SENSOR 9
VS
18
PS+
19
PS-
25
GND
V
+ 5V 8 9 or
5 GND
Signal
Ground
Figure 2.16 - Input PNP command using 11000 scanner power
The electrical features are given below: Maximum voltage: Maximum current:
30 VDC 25 mA
An anti-disturbance filter is implemented on the presence sensor input with a nominal delay of about 5 milliseconds.
2.14 - Installation
Page 28
LazerData® 11000 Scanner
Installation Manual
2.4.5 Outputs The outputs are available only on 25-pin connector models. The following pins are present on the 25-pin connector of the scanner: 25-Pin 8 22 11 12
Name NO READ+ I/O REFRIGHT+ I/O REF-
Function No read output (+) I/O reference Right read output (+) I/O reference
11000 scanner 25-pin
11000 scanner 25-pin
USER INTERFACE Vext
11 RIGHT+ I/O REF
12 and/or
8
NO READ+
22
I/O REF
40 VDC max
Figure 2.17 - Output connections
The NO READ output activates when the code signaled by the presence sensor is not decoded. The RIGHT output activates when the code is decoded correctly. These outputs are both level- or pulse-programmable: a 50-ms pulse is generated in the second case.
Installation - 2.15
Page 29
LazerData® 11000 Scanner
2.5
Installation Manual
POSITIONING
The LaserData® 11000 Scanner is able to decode moving bar code labels at a variety of angles. However, significant angular distortion may degrade reading performance. When mounting the scanner, take into consideration these three ideal label-position angles: Pitch 0°, Skew 10° to 30°, and Tilt 0°. Follow these suggestions for the best orientation: The Pitch angle is represented by the angle P in Figure 2.18. Position the reader in order to minimize the Pitch angle. P
11000 scanner
Figure 2.18 - Pitch Angle
The Skew angle is represented by the angle S in Figure 2.19. Position the reader to obtain a Skew angle of at least 10°. This avoids the direct reflection of the laser light emitted by the scanner. For the raster version, this angle refers to the most inclined or external raster line, so that all other raster lines have more than 10° Skew.
S 11000 scanner Figure 2.19 - Skew angle
2.16 - Installation
Page 30
LazerData® 11000 Scanner
Installation Manual
The Tilt angle is represented by the angle T in Figure 2.20. Position the reader in order to minimize the Tilt angle. T
11000 scanner Figure 2.20 - Tilt angle
2.6
TYPICAL LAYOUTS
When an object – bearing a bar code label – enters the scanner’s reading zone, a photoelectric sensor senses the presence of the symbol and activates the scanner.
11000 scanner
1
Host 2
1
Main serial interface
2
Presence sensor
Figure 2.21 - Typical layout
Installation - 2.17