The text of a manual · part 2 of 5
LazerData 11000 Series Bar Code Scanner Installation Manual, pages 11 to 20
Pages 11 to 20 of 48
The original document is the PDF (375 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 11000 and Datalogic 11000
Page 11
LazerData® 11000 Scanner
1.2
Installation Manual
DESCRIPTION
Some of the main features of the LazerData® 11000 Scanner are, • small size • scanning speed of up to 600 scans/s • raster version availability • serial communication interfaces (one or two) • readability of all popular codes • supply voltage range from 10 to 30 VDC • test mode, for verification of reading features and exact scanner positioning without need for external tools • programmability in four different operating modes, to suit the most varied bar code reading system requirements • low power consumption The scanner uses a solid-state laser diode as a light source. The light emitted has a wavelength between 630 and 680 nm. Refer to the section “Safety Precautions” at the beginning of this manual for information on laser safety. With an IP65 protection class enclosure, the reader is suitable for industrial environments where high protection against harsh external conditions is required. The four LEDs on the side of the scanner indicate the following: PWR/TXD c
(red) (Figure A., ) indicates the reader is connected to the power supply or, when blinking (green), data transmission.
e) signals possible, successful bar code reading. (yellow) (Figure A.,d) indicates the code presence sensor is
GOOD READ (red) (Figure A., EXT TRIG active. LASER ON j
(green) (Figure A., f) indicates laser ON state.
The screw holes on the body of the reader are for mechanical fixture (Figure A., ). 1.2 - General Features
Page 12
LazerData® 11000 Scanner
Installation Manual
1.3
AVAILABLE MODELS
The LazerData 11000 Scanner is available in models with variances in the following • Resolution • Interface module and cable termination • Linear or raster models • Performance
The following models are available, L D 11 0 X 1 X 1
R S 2 3 2 /R S 2 3 2 S td (3 5 0 s /s)
®
L a ze rD a ta 2 11 0 0 0 S e rie s S c an n ers
5 -m W la s e r
S tan d ard res o lu tio n lin e a r
H ig h re s o lu tio n lin e ar S td re s ra ste r p a tte rn 1 B la n k
H ig h re s ras ter p a tter n 1
1
R S 2 3 2 /R S 2 3 2 H i (6 0 0 s /s )
3
R S 2 3 2 /R S 4 8 5 S td (3 5 0 s /s)
4
R S 2 3 2 /R S 4 8 5 H i (6 0 0 s /s )
5
R S 2 3 2 /2 0 -m A C L S td (3 5 0 s /s )
2 6
R S 2 3 2 /2 0 -m A C L H i (6 0 0 s/s)
7
R S 2 3 2 W W S td (3 5 0 s /s )
3 4
5
8
R S 2 3 2 W W H i (6 0 0 s /s )
IP 6 5 P ro te c tio n C la s s
General Features - 1.3
Page 13
LazerData® 11000 Scanner
1.4
Installation Manual
LD11-90 DEFLECTION MIRROR
The LD11-90DEG Deflection Mirror is available on request for the LazerData 11000 Scanner. The installation of the LD11-90DEG Deflection Mirror is very easy (see Figure 1-1).
CAUTION Avoid any contact with the deflection mirror, mirrored rotor, the lenses, or other optical components. Otherwise, the performance of the reader will be reduced.
1. Turn off the device. 2. Remove the scanning window by unscrewing the two cover screws. 3. Attach the mirror to the device by means of the two fixing screws. 4. Remount the scanning window so that the opening face is now at 90° with respect to the scanner body.
90° deflection mirror
Cover screws
Scanning window
Fixing screws
Figure 1-1. Installation of the Deflection Mirror
1.4 - General Features
Page 14
LazerData® 11000 Scanner
Installation Manual
2
INSTALLATION
2.1
PACKAGE CONTENTS
Verify that the LazerData® 11000 Series Bar Code Scanner and all the parts supplied with the equipment are present and intact when opening the packaging. The list of parts includes: 1. LazerData® 11000 Scanner with cable 2. This installation manual 3. Bar code test chart (PCS = 0.9) 4. LazerData® 11000 Series Scanner configuration program disk 5. Mounting kit – bracket and screws 2
4
3
5
1
Figure 2.1 - LazerData® 11000 Scanner package contents
Installation - 2.1
Page 15
LazerData® 11000 Scanner
2.2
Installation Manual
GUIDE TO INSTALLATION
The following can be used as a checklist to verify all of the steps necessary for complete installation of the LazerData® 11000 Scanner. 1.
Read all information in the section "Safety Precautions” at the beginning of this manual.
2.
Correctly position and mount the scanner for bar code reading according to the information in sections 2.3, 2.5, and 3.4.
3.
Provide correct system cabling according to the signals necessary (see all of section 2.4).
4.
The Standard Application Program default setting and the instructions to perform software configuration are available in the LDHOST help file.
NOTE Fine tuning of the scanner position for bar code reading can be accomplished using the Test Mode as described in LDHOST.
The installation is now complete.
2.2 - Installation
Page 16
LazerData® 11000 Scanner
Installation Manual
2.3
MECHANICAL INSTALLATION
The LazerData® 11000 Scanner can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A., ). See the diagrams below for the overall dimensions of the scanner and mounting bracket that may be used for installation.
j
Refer to section 2.5 for correct positioning.
mm in
Mounting Bracket bottom view
Figure 2.2 - Overall dimensions
Installation - 2.3
Page 17
LazerData® 11000 Scanner
2.4
Installation Manual
ELECTRICAL CONNECTIONS
Several LazerData® 11000 Scanner models are equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
Figure 2.3 - 25-pin female D-sub connector 25-pin D-sub connector pinout Pin 13
Name VS
Function Power supply input voltage (+)
25
GND
Power supply input voltage (-)
1
CHASSIS
Chassis Ground
9
VS
Presence sensor supply voltage (+)
18
PS+
Presence sensor (+)
19
PS-
Presence sensor (-)
8
NO READ +
No read output (+)
22
I/O REF
I/O reference
11
RIGHT +
Right read output (+)
12
I/O REF
I/O reference
2*
TX232/TX485+/CLOUT+
3*
RX232/RX485+/CLIN+
* Main interface signals
4*
RTS232/TX485-/CLOUT-
(see par. 2.4.2)
5*
CTS232/RX485-/CLIN-
7
SGND
20
RXAUX
Signal Ground Auxiliary input
21
TXAUX
Auxiliary output
23
CTSAUX
Auxiliary handshake
24 RTSAUX 6, 10, 14, 15, NC 16, 17
Auxiliary handshake No Connect
*Pins 2, 3, 4, and 5 of the 25-pin connector have different functions depending on the scanner model.
2.4 - Installation
Page 18
LazerData® 11000 Scanner
Installation Manual
Some scanner models are equipped with a 9-pin female connector. The details of the connector pins are indicated in the following table: 1
5
9
6
Figure 2.4 - 9-pin female connector 9-pin connector pinout Pin 7 5 8 9 1 2 3 4 6
Name VS GND PS+ PSCHASSIS TX232 RX232 CTS232 RTS232
Function Power supply input voltage (+) Power supply input voltage (-) Presence sensor (+) Presence sensor (-) Main output Main input Main handshake Main handshake
2.4.1 Power supply Power can be supplied to the scanner through the pins provided on the 25- or 9-pin connector used for communication with the host (Figure 2.5): 11000 scanner 9-pin
11000 scanner 25-pin
7
13
USER INTERFACE VS
V+ (10 - 30 VDC)
VS 5 or
25
GND 1 CHASSIS
1
GND
VGND
CHASSIS
CHASSIS
Earth Ground
Figure 2.5 - Power supply connections
The power must be between 10 and 30 VDC only. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
Installation - 2.5
Page 19
LazerData® 11000 Scanner
Installation Manual
2.4.2 Main serial interface The signals relative to the following serial interface types are available on the input/output connector of the scanner depending on the scanner model (see section 1.3). If the interface type is not compatible with the current communication handshaking, then the system forces the XON/XOFF protocol. The parameters relative to the interface selected (baud rate, data bits, etc.) can be defined using the LDHOST utility program or "Host Mode" programming provided on diskette. Details regarding the connections and use of the interfaces are given in the next sections.
RS232 interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner. This is the default setting. The following pins are used for RS232 interface connection: 9-Pin 2 3 6 4 5
2.6 - Installation
25-Pin 2 3 4 5 7
Name TX232 RX232 RTS232 CTS232 GND/SGND
Function Transmitted Data Received Data Request To Send Clear To Send Signal Ground
Page 20
LazerData® 11000 Scanner
Installation Manual
11000 scanner 9-pin
11000 scanner 25-pin
USER INTERFACE
2
2
TX232
3
3
RX232
6
4
RTS232
4
5
CTS232
5
7
SGND
TX232
RXD
RX232
TXD
RTS232 or
DCD
CTS232
DTR
SGND
SGND
RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 2.6 - RS232 main interface connections
START OF TRANSMISSION +V RTS -V
END OF TRANSMISSION
DATA TRANSMISSION
+V TX DATA -V
D1
DATA TRANSMISSION D3
D2
D4
D5
TRANSMISSION STOPPED
ENABLED
ENABLED +V RTS -V IDLE
DISABLED
IDLE
Figure 2.7 - RS232 control signals
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the scanner activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
Installation - 2.7