Page 11

LazerData® 11000 Scanner

1.2

Installation Manual

DESCRIPTION

Some of the main features of the LazerData® 11000 Scanner are, • small size • scanning speed of up to 600 scans/s • raster version availability • serial communication interfaces (one or two) • readability of all popular codes • supply voltage range from 10 to 30 VDC • test mode, for verification of reading features and exact scanner positioning without need for external tools • programmability in four different operating modes, to suit the most varied bar code reading system requirements • low power consumption The scanner uses a solid-state laser diode as a light source. The light emitted has a wavelength between 630 and 680 nm. Refer to the section “Safety Precautions” at the beginning of this manual for information on laser safety. With an IP65 protection class enclosure, the reader is suitable for industrial environments where high protection against harsh external conditions is required. The four LEDs on the side of the scanner indicate the following: PWR/TXD c

(red) (Figure A., ) indicates the reader is connected to the power supply or, when blinking (green), data transmission.

e) signals possible, successful bar code reading. (yellow) (Figure A.,d) indicates the code presence sensor is

GOOD READ (red) (Figure A., EXT TRIG active. LASER ON j

(green) (Figure A., f) indicates laser ON state.

The screw holes on the body of the reader are for mechanical fixture (Figure A., ). 1.2 - General Features

Page 12

LazerData® 11000 Scanner

Installation Manual

1.3

AVAILABLE MODELS

The LazerData 11000 Scanner is available in models with variances in the following • Resolution • Interface module and cable termination • Linear or raster models • Performance

The following models are available, L D 11 0 X 1 X 1

R S 2 3 2 /R S 2 3 2 S td (3 5 0 s /s)

®

L a ze rD a ta 2 11 0 0 0 S e rie s S c an n ers

5 -m W la s e r

S tan d ard res o lu tio n lin e a r

H ig h re s o lu tio n lin e ar S td re s ra ste r p a tte rn 1 B la n k

H ig h re s ras ter p a tter n 1

1

R S 2 3 2 /R S 2 3 2 H i (6 0 0 s /s )

3

R S 2 3 2 /R S 4 8 5 S td (3 5 0 s /s)

4

R S 2 3 2 /R S 4 8 5 H i (6 0 0 s /s )

5

R S 2 3 2 /2 0 -m A C L S td (3 5 0 s /s )

2 6

R S 2 3 2 /2 0 -m A C L H i (6 0 0 s/s)

7

R S 2 3 2 W W S td (3 5 0 s /s )

3 4

5

8

R S 2 3 2 W W H i (6 0 0 s /s )

IP 6 5 P ro te c tio n C la s s

General Features - 1.3

Page 13

LazerData® 11000 Scanner

1.4

Installation Manual

LD11-90 DEFLECTION MIRROR

The LD11-90DEG Deflection Mirror is available on request for the LazerData 11000 Scanner. The installation of the LD11-90DEG Deflection Mirror is very easy (see Figure 1-1).

CAUTION Avoid any contact with the deflection mirror, mirrored rotor, the lenses, or other optical components. Otherwise, the performance of the reader will be reduced.

1. Turn off the device. 2. Remove the scanning window by unscrewing the two cover screws. 3. Attach the mirror to the device by means of the two fixing screws. 4. Remount the scanning window so that the opening face is now at 90° with respect to the scanner body.

90° deflection mirror

Cover screws

Scanning window

Fixing screws

Figure 1-1. Installation of the Deflection Mirror

1.4 - General Features

Page 14

LazerData® 11000 Scanner

Installation Manual

2

INSTALLATION

2.1

PACKAGE CONTENTS

Verify that the LazerData® 11000 Series Bar Code Scanner and all the parts supplied with the equipment are present and intact when opening the packaging. The list of parts includes: 1. LazerData® 11000 Scanner with cable 2. This installation manual 3. Bar code test chart (PCS = 0.9) 4. LazerData® 11000 Series Scanner configuration program disk 5. Mounting kit – bracket and screws 2

4

3

5

1

Figure 2.1 - LazerData® 11000 Scanner package contents

Installation - 2.1

Page 15

LazerData® 11000 Scanner

2.2

Installation Manual

GUIDE TO INSTALLATION

The following can be used as a checklist to verify all of the steps necessary for complete installation of the LazerData® 11000 Scanner. 1.

Read all information in the section "Safety Precautions” at the beginning of this manual.

2.

Correctly position and mount the scanner for bar code reading according to the information in sections 2.3, 2.5, and 3.4.

3.

Provide correct system cabling according to the signals necessary (see all of section 2.4).

4.

The Standard Application Program default setting and the instructions to perform software configuration are available in the LDHOST help file.

NOTE Fine tuning of the scanner position for bar code reading can be accomplished using the Test Mode as described in LDHOST.

The installation is now complete.

2.2 - Installation

Page 16

LazerData® 11000 Scanner

Installation Manual

2.3

MECHANICAL INSTALLATION

The LazerData® 11000 Scanner can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A., ). See the diagrams below for the overall dimensions of the scanner and mounting bracket that may be used for installation.

j

Refer to section 2.5 for correct positioning.

mm in

Mounting Bracket bottom view

Figure 2.2 - Overall dimensions

Installation - 2.3

Page 17

LazerData® 11000 Scanner

2.4

Installation Manual

ELECTRICAL CONNECTIONS

Several LazerData® 11000 Scanner models are equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:

Figure 2.3 - 25-pin female D-sub connector 25-pin D-sub connector pinout Pin 13

Name VS

Function Power supply input voltage (+)

25

GND

Power supply input voltage (-)

1

CHASSIS

Chassis Ground

9

VS

Presence sensor supply voltage (+)

18

PS+

Presence sensor (+)

19

PS-

Presence sensor (-)

8

NO READ +

No read output (+)

22

I/O REF

I/O reference

11

RIGHT +

Right read output (+)

12

I/O REF

I/O reference

2*

TX232/TX485+/CLOUT+

3*

RX232/RX485+/CLIN+

* Main interface signals

4*

RTS232/TX485-/CLOUT-

(see par. 2.4.2)

5*

CTS232/RX485-/CLIN-

7

SGND

20

RXAUX

Signal Ground Auxiliary input

21

TXAUX

Auxiliary output

23

CTSAUX

Auxiliary handshake

24 RTSAUX 6, 10, 14, 15, NC 16, 17

Auxiliary handshake No Connect

*Pins 2, 3, 4, and 5 of the 25-pin connector have different functions depending on the scanner model.

2.4 - Installation

Page 18

LazerData® 11000 Scanner

Installation Manual

Some scanner models are equipped with a 9-pin female connector. The details of the connector pins are indicated in the following table: 1

5

9

6

Figure 2.4 - 9-pin female connector 9-pin connector pinout Pin 7 5 8 9 1 2 3 4 6

Name VS GND PS+ PSCHASSIS TX232 RX232 CTS232 RTS232

Function Power supply input voltage (+) Power supply input voltage (-) Presence sensor (+) Presence sensor (-) Main output Main input Main handshake Main handshake

2.4.1 Power supply Power can be supplied to the scanner through the pins provided on the 25- or 9-pin connector used for communication with the host (Figure 2.5): 11000 scanner 9-pin

11000 scanner 25-pin

7

13

USER INTERFACE VS

V+ (10 - 30 VDC)

VS 5 or

25

GND 1 CHASSIS

1

GND

VGND

CHASSIS

CHASSIS

Earth Ground

Figure 2.5 - Power supply connections

The power must be between 10 and 30 VDC only. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.

Installation - 2.5

Page 19

LazerData® 11000 Scanner

Installation Manual

2.4.2 Main serial interface The signals relative to the following serial interface types are available on the input/output connector of the scanner depending on the scanner model (see section 1.3). If the interface type is not compatible with the current communication handshaking, then the system forces the XON/XOFF protocol. The parameters relative to the interface selected (baud rate, data bits, etc.) can be defined using the LDHOST utility program or "Host Mode" programming provided on diskette. Details regarding the connections and use of the interfaces are given in the next sections.

RS232 interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner. This is the default setting. The following pins are used for RS232 interface connection: 9-Pin 2 3 6 4 5

2.6 - Installation

25-Pin 2 3 4 5 7

Name TX232 RX232 RTS232 CTS232 GND/SGND

Function Transmitted Data Received Data Request To Send Clear To Send Signal Ground

Page 20

LazerData® 11000 Scanner

Installation Manual

11000 scanner 9-pin

11000 scanner 25-pin

USER INTERFACE

2

2

TX232

3

3

RX232

6

4

RTS232

4

5

CTS232

5

7

SGND

TX232

RXD

RX232

TXD

RTS232 or

DCD

CTS232

DTR

SGND

SGND

RTS/CTS HARDWARE HANDSHAKING ENABLED

Figure 2.6 - RS232 main interface connections

START OF TRANSMISSION +V RTS -V

END OF TRANSMISSION

DATA TRANSMISSION

+V TX DATA -V

D1

DATA TRANSMISSION D3

D2

D4

D5

TRANSMISSION STOPPED

ENABLED

ENABLED +V RTS -V IDLE

DISABLED

IDLE

Figure 2.7 - RS232 control signals

The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the scanner activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.

Installation - 2.7