Page 31
LazerData® 11000 Scanner
Installation Manual
2.6.1 Master-slave The master-slave connection is used to collect data from several scanners to build a multisided reading system. There can be one master and up to 5 slaves connected with the RS485–polled mode on the main serial interface. The master scanner is also connected to a host PC with the RS232 auxiliary interface. The P.S. signal is unique to the system. There is a single reading phase and a single message from the master scanner to the host PC.
2
11000 scanner
Slave 11000 scanner
1
Master 11000 scanner
Slave 3 1 Auxiliary serial interface 2 RS485 Main serial interface 3 Presence sensor
Host
Figure 2.22 - Master-slave layout
NOTE The auxiliary serial port of the slave scanners is only used for configuration. The termination resistors of the RS485 bus must not be installed.
2.18 - Installation
Page 32
LazerData® 11000 Scanner
Installation Manual
2.6.2 Local echo In Local Echo mode the data is transmitted on both the Auxiliary interface and on the Main interface. Host Mode programming can be accomplished either through the Main interface or the Auxiliary interface in Local Echo mode.
Terminal
11000 scanner
2
1
Host
3
1 Main serial interface 2 Auxiliary serial interface 3 Presence sensor Figure 2.23 - Local echo layout
Installation - 2.19
Page 33
LazerData® 11000 Scanner
Installation Manual
2.6.3 Pass Through Pass Through mode allows two or more devices to be connected to a single external serial interface. Each 11000 Scanner transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. The main and auxiliary ports are connected as shown in Figure 2.24 below.
2
11000 scanner
1
Host 1
3
3 1 Main serial interface 2 Auxiliary serial interface 3 Presence sensor Figure 2.24 - Pass through layout
2.20 - Installation
11000 scanner
Page 34
LazerData® 11000 Scanner
Installation Manual
3
READING FEATURES
The number of scans performed on the code by the scanner – and, therefore, the decoding capability – is influenced by the following factors: • • • • number of scans per second code motion speed label dimensions scan direction with respect to code motion
Allow at least five scans during the code passage to ensure a successful read.
3.1
STEP LADDER MODE Code motion direction at LS speed
LH 11000 scanner Laser Beam
Figure 3.1 - "Step Ladder" Scanning Mode
If scanning is perpendicular to the code motion direction (Figure 3.1 - "Step Ladder" Scanning Mode), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 Where:
SN LH LS SS
= = = = number of effective scans label height (in mm or inches) label movement speed (in mm/s or inches/s) number of scans per second
Reading Features - 3.1
Page 35
LazerData® 11000 Scanner
Installation Manual
For example, the 11000 Scanner (scanning at 350 scans/s) for a 25-mm high code moving at 500 mm/s performs: SN = [(25/500) * 350] - 2 = 15 effective scans.
3.2
PICKET FENCE MODE Code motion direction at LS speed 11000 scanner
Laser Beam LW FW
Figure 3.2 - "Picket Fence" Scanning Mode
If scanning is parallel to the code motion, (Figure 3.2 - "Picket Fence" Scanning Mode), the number of effective scans is given by: SN = {[(FW-LW)/LS] * SS} -2 Where:
SN = FW = LW = LS = SS = number of effective scans reading field width (in mm or inches) label width (in mm or inches) label movement speed (in mm/s or inches/s) scans/s
For example, for a 50-mm wide code moving in a point where the reading field is 200 mm wide and the label is moving at 1500 mm/s, the 11000 Scanner (scanning at 350 scans/s), performs SN = {[(200-50)/1500] * 350} - 2 = 33 effective scans
3.2 - Reading Features
Page 36
Installation Manual
3.3
LazerData® 11000 Scanner
PERFORMANCE
3.3.1 Optical resolution The LazerData® 11000 Scanner is available in two optical resolution models (see section 1.3). The Standard resolution version is a general purpose model with optical resolution that allows code reading from 0.20-mm to 1-mm (approx. 8- to 39-mil) narrow bars in the zone between 40 and 300 mm (1.6 and 12 inches) from the emission window. The High resolution version has an optical resolution that allows reading very high density codes. Typical values are from 0.15-mm to 0.30-mm (approx. 6- to 12-mil) narrow bars in the zone from 30 to 90 mm (1.2 to 3.6 inches) from the emission window. Refer to the diagrams given in section 3.4 for further details on the reading features. These diagrams refer to the two optical versions and are taken on varied resolution sample codes at a 25°C (77°F) ambient temperature, depending on the conditions given in the notes under each diagram.
3.3.2 Scanning speed The 11000 Scanner is also available in two standard scanning performance models. The Standard performance version has a scanning speed of 350 scans/s. The High performance version has a scanning speed of 600 scans/s and offers better performance on 0.20- to 0.30-mm (approx. 8- to 12-mil) resolution codes.
3.3.3 Raster The maximum capture of the raster version is 18 mm (0.7 inch) at a 300-mm (12-inch) distance. If standard devices do not satisfy your specific requirements, send a representative code sample of your labels to the nearest PSC Automation distributor, who will in turn supply you with complete information on the reading possibilities.
Reading Features - 3.3
Page 37
LazerData® 11000 Scanner
3.4
Installation Manual
READING DIAGRAMS
LD-11011X or -11031X (Standard Resolution, 350 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
2
4
6
8
10
6
4 code 12 mil
2 code 8 mil 0 code 20 mil 24 mil 32 mil 39 mil
2
4
6 in.
CONDITIONS: Code PCS
= Interleaved 2/5 or Code 39 = 0.90
"Pitch" angle
= 0°
"Skew" angle
= 10°
"Tilt" angle
= 0°
3.4 - Reading Features
12 in.
Page 38
LazerData® 11000 Scanner
Installation Manual
LD-11021X or -11051X (High resolution, 350 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
1
2
3
4
5 in.
2 code 12 mil
1 code 6 mil
0 code 8 mil
1
2 in.
CONDITIONS: Code
= Interleaved 2/5 or Code 39
PCS "Pitch" angle
= 0.90 = 0°
"Skew" angle "Tilt" angle
= 10° = 0°
Reading Features - 3.5
Page 39
LazerData® 11000 Scanner
Installation Manual
LD-11011X or -11031X (Standard resolution, 600 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
2
4
6
8
10
6
4
2 code 8 mil
0
2 code 12 mil code 12 mil code 20 mil 24 mil 32 mil 39 mil
4
6 in.
CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle 3.6 - Reading Features
= = = = =
Interleaved 2/5 or Code 39 0.90 0° 10° 0° code 20 mil 24 mil 32 mil 39 mil
12 in.
Page 40
LazerData® 11000 Scanner
Installation Manual
LD-11021X or -11051X (High resolution, 600 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
1
2
3
4
5 in.
2 code 8 mil 1 code 4 mil
0 code 6 mil
1
2 in.
CONDITIONS: Code
= Interleaved 2/5 or Code 39
PCS "Pitch" angle
= 0.90 = 0°
"Skew" angle "Tilt" angle
= 10° = 0°
Reading Features - 3.7