The text of a manual · part 5 of 6
DP2000-P, DP9000-P Process Indicators, pages 41 to 50
Pages 41 to 50 of 60
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omega DP2000
Page 41
4. Using the same LI, UI, LD, and UD numbers, calculate the Gain (G) in Counts/Input.
Gain (G) = (UD - LD)= (UI - LI)
5. Select the voltage range which contains the Gain (G) number calculated in step 4.
Output Count Range Voltage Receiver Input
Selection Span DP2000P DP9000P P1 0/0.5 V 80/2850 400/14250 P2 0/0.5 V 2840/5500 14200/27500 P3 0/0.5 V 5490/8170 27450/40850 P4 0/5.0 V 8/231 40/1155 P5 0/5.0 V 230/449 1150/2245 P6 0/10.0 V 4/114.5 20/572 P7 0/10.0 V 114/223 570/1115 VR = (Counts/Volts) This selection will be used in configuration (Section 21.3). 6. Proceed to Installation (Section 20.4).
37
Page 42
20.3.4 Current Receiver Selection CR1.2,3,.4,5,.6,.7,8,9,10,11,12,13,.14,15,16,.17,18,19,20,21,22,23,24
1. Using the Input Span Range and the required Display Reading, calculate the zero offset required (with polarity).
(LI) Lower Input = (Ul) Upper Input = (LD) Lower Display = (UD) Upper Display =
2. When specifying the Lower Input (LI) and Upper Input (Ul), the maximum display reading for a DP2000-P is +1999. The maximum reading for a DP9000-P is +9999.
ZON = _(LDx Ul) - (UDx LI) (UI - LI)
3. Select a Zero Offset Range (ZO) from the appropriate OMEGA series where the calculated Zero Offset Number (ZON) falls between the minimum and maximum numbers of that range.
DP2000-P DP9000-P ZO1 = -3000/-1895 ZO1 = -15000/-9475 ZO2 = -1900/-600 ZO2 = -9500/-3000 ZO3 = -605/+870 ZO3 = -3025/+4350 (204 = +865/+2100 ZO4 = +4325/+10500 ZO = This selection will be used in configuring the meter (Section 21.5).
4. Using the same LI, Ul, LD, and UD numbers used, calculate the Gain (G) in Counts/Input.
Gain (G) = (UD - LD) = (UI - LI)
5. Using the chart on page 39, select the Count Output Range required for the Input Span Range chosen.
6. Select the group of four CR ranges under the Input Span Range required.
7. Select one of the four ranges which contains the Gain (G) number calculated.
38
Page 43
Counts per Milliamp Current Receiver Input
Selection Span DP2000-P DP9000-P P8 4.0/20.0 mA 2.5/70.4 13/352 P9 4.0/20.0 mA 70.2/137 351/685 P10 10.0/50.0 mA 1/28.2 5/141 P11 10.0/50.0 mA 28.1/55 141/275 CR = (Counts/mA) This selection will be used in configuration (Section 21.4). 8. Proceed to Installation (Section 20.4).
39
Page 44
20.4 INSTALLATION
20.4.1
20.4.2
NOTE:
General If unit is to be configured as a voltmeter (VM1-15) or an ammeter (AM1-18) then zero offset (Z03) is required.
Select the Voltmeter (VM1-15), Ammeter (AM1-18), Voltage Receiver (VR1-24), Current Receiver (CR1,24), and/or the Zero Offset (201-4) required. Install the push-on jumpers as per pages 44 through 52 depending on which range is required.
Reference Voltage (DP9000-P only)
Select reference RV2 by removing any jumpers on position S3 as per Subsection 13.3 in Main Assembly Section DP90/DP98.
Decimal Point If a decimal point is required, refer to the appropriate Main Assembly Section for location and configuration procedure.
lf using Main Assembly DP2000, refer to Section DP20/DP29. lf using Main Assembly DP9000, refer to Section DP90/DP98.
40
Page 45
21.0 CONFIGURATION CHARTS 21.1 VOLTMETER (VM1-6)
Zero (Z) ~~ os
Span (S) 7 |
$1 B-8°'B 848 8:8 B°B°R 8°88 Bon configuration(s).
Step 1: Remove all push-on jumpers not used in the desired install the push-on jumpers indicated.
Step 2: Select the desired configuration from the chart below, then
Contiguration* $1 $2 $3 sistance VM1 +190/235 mV B Cc D G - 100 kOhms VM2 | +233/350 mV | B A D| Gi] - 100 kOhms VM3 | +348/450 mV | B B C} G]{ - 100 kOhms VM4 +440/580 mV B C D H - 230 kOhms VMS | +575/850 mV | B A D{H] - 230 kOhms VM6 {| +800/1030 mV] B Cc Di J - 385 kOhms
* Used on the DP2000-P or DP9000-P.
41
Page 46
VOLTMETER (VM7-15)
Zero Zw + RI Le L3 $2 $3 | R2 HEH Span (s) 7” caer fl |\ HS $1 $2 s3 8 & A 8 B-8°:8 8-48 Be ee ee E F
BS 8° Bon i oe oe
G H a8 GB
K ot oe
Voltmeter Input
Configuration* S1 $2 $3 Resistance VM7 +1.0/1.5 V B A D J - 385 kOhms VM8 +1.4/1.8 V B Cc D J K 325 kOhms VM9 | +1.7/2.5 V B A D J K 325 kOhms VM10 | +2.4/3.1 V B Cc D | - 1 MOhm VM11 | +3.0/4.5 V B A D | - 1 MOhm VM12 | +4.4/5.1 V B B Cc | - 1 MOhm VM13 | +5.0/6.5 V B Cc D K - 1 MOhm VM14 | +6.4/9.6 V B A D K - 1 MOhm VM15 4 +9.5/11.0 V B B C K - 1 MOhm
* Used on the DP2000-P or DP9000-P.
42
Page 47
21.2 AMMETER (AM1-6)
$1
Zero (Z) ~~
Span (Ss), ™
$1
Ll
Ls
B-8°R 8:58 8: B:8°8 8:8 OR s
Step 1: Remove all push-on jumpers not used in the desired configuration(s).
Step 2: Select the desired configuration from the chart below, then install the push-on jumpers indicated.
Configuration* $1 $2 $3 Resistance AMi | +370/470uA | B | C | D | A { G1] 490 ohms AM2 | +460/700uA | B | A | D | A | GI 490 ohms AM3 | +690/800uA | B | B | C | A | GI 490 ohms AM4 | +790/9940uA {| B | C | D {|B { G{ 240 ohms AMS | +935/1400 uA} B | A | D |B | G]| 240 ohms AM6 | +1.39/1.91 uA] B | B | GC | B | G | 240 ohms
* Used on the DP2000-P or DP9000-P.
43
Page 48
AMMETER (AM7-18)
Zero (Z) ee fo m1 s2 133 R2| sass] 1 sans) \e $1 $2 | $3 vd a B-8°S 8-48 oe an on a2°o8 ce BoM SEES tT
K ot a 8
Configuration* $1 $2 S3 Resistance AM7 | +1.90/2.35 mA | B C D D G 100 ohms AM8 | +2.33/3.50 mA | B A D D G 100 ohms AMS | +3.48/4.00 mA | B B C D G 100 ohms AM10 | +3.90/4.70 mA | B Cc D F G 50 ohms AM11 | +4.65/7.00 mA } B A D F G 50 ohms AM12 | +6.90/7.80 mA | B B C F G 50 ohms AM13 | +7.70/9.40 mA | B C D E G 25 ohms AM14 | +9.35/14.0 mA | B A D E G 25 ohms AM15 | +13.9/19.1 mA | B B C;E |G 25 ohms AM16 | +19.0/23.5 mA | B Cc D Cc G 10 ohms AM17 | +23.3/35.0 mA | B A D C G 10 ohms AM18 | +34.0/51.0 mA | B B C C G 10 ohms
* Used on the DP2000-P or DP9000-P.
44
Page 49
Zero (Z), w~ \
VOLTAGE RECEIVER (P1-P7)
_ - Z
Span (S) _V7 | $1 $2 | s3 8 8 A 8B E-8°'R 8-48 8:8 a8 =-e S:°8°8 8°88 Bon Bee fS G H 2 '8 8-8 K ot oe Step 1: Remove all push-on jumpers not called out for the configuration(s) desired. Step 2: Select the desired configuration from the chart below and install the push-on jumpers indicated.
Voltage Receiver Counts/Volt | Counts/Volt Configuration $2 $3 DP2000-P DP9000-P P1 0.5 V Input A B G 80/2850 400/14250 P2 0.5 V Input B C G 2840/5500 14200/27500 P3 0.5 V Input A D G 5490/8170 27450/40850
P4 5.0 V Input A B | 8/231 40/1155 P5 5.0 V Input B {cll 230/449 1150/2245
-P6 }.10.0.Vinput | A | Bl K {| 4/1145 4 20/572 | P7 10.0 V Input B C K 114/223 570/1115
45
Page 50
CURRENT RECEIVER
(P8-P11) | $1 Zero (2) ~~ fr fs R1 $2 $3 z2] Teersee lan Span (S), ™ || \ ascp \ \ $1 \ $2 | s3 8 A B B-8°'S 84S 8's Es BOB E Ff Boe 8°88 Bon Sag sq G H G8 8 K ot i | Step 1: Remove all push-on jumpers not called out for the configuration(s) desired. Step 2: Select the desired configuration from the chart below and install the push-on jumpers indicated. Current Receiver Counts/mA | Counts/mA Configuration $2 $3 DP2000-P DP9000-P P8 4.0/20.0 mA Input A B E |G 2.5/70.4 12/352 PQ 4.0/20.0 mA Input B C E |G 70.2/137 351/685 P10 | 10.0/50.0 mA Input | A B Ci G 1/28.2 5/141 P11 | 10.0/50.0 mA Input B C; Cc; G 28.1/55 140/275
46