Page 71
Scanner Parameters
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
QX-870 Industrial Raster Scanner User Manual
5-5
Page 72
Communication
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner. Note: Command processing is always enabled for RS-232 A.
Data Data enables RS-232 A as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-6
QX-870 Industrial Raster Scanner User Manual
Page 73
Scanner Parameters
RS-232 B The following settings define the basic transmission speeds and digital standards that ensure common RS-232 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
QX-870 Industrial Raster Scanner User Manual
5-7
Page 74
Communication
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
5-8
QX-870 Industrial Raster Scanner User Manual
Page 75
Scanner Parameters
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner.
Data Data enables RS-232 B as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
QX-870 Industrial Raster Scanner User Manual
5-9
Page 76
Communication
RS-422 The following settings define the basic transmission speeds and digital standards that ensure common RS-422 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
5-10
QX-870 Industrial Raster Scanner User Manual
Page 77
Scanner Parameters
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
QX-870 Industrial Raster Scanner User Manual
5-11
Page 78
Communication
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner.
Data Data enables RS-422 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-12
QX-870 Industrial Raster Scanner User Manual
Page 79
Scanner Parameters
Ethernet Status Enables or disables Ethernet connectivity in the scanner. Important: For further information about setting up TCP/IP with a PC, see Appendix G – Configuring Ethernet TCP/IP.
QX-870 Industrial Raster Scanner User Manual
5-13
Page 80
Communication
IP Address Enter the IP address of the scanner in this field.
5-14
QX-870 Industrial Raster Scanner User Manual