Page 61

Scanner Setup

Rules for Output Filter Configuration Output Filter Configuration Rule # 1 Each symbol that is decoded must match one of the filters before it can be saved to a read cycle record. There is an exception to this rule, however, when the number of symbols required for a read cycle exceeds the number of active filters. In such a case, unfiltered symbols can be placed into unfiltered output positions. For example, if the number of symbols required is 6 but there are only 5 active filters, the last position can be filled by any (unfiltered) qualified symbol.

Output Filter Configuration Rule # 2 The same filter setup can be used multiple times. For example, filters 1, 2, and 3 can be set up to filter Code 39 symbols, and the output will occur in the order the symbols are decoded.

Output Filter Configuration Rule # 3 All qualified symbols will be sorted and output in the matching filter position. If a symbol matches filter 3, it will be output as the third symbol. If a filter does not have a matching qualified symbol, a No Read message will be output in place of the symbol (assuming the No Read message is enabled). For example, if there is not a symbol that meets filter 3’s requirements, then a No Read message will be output in the third output position.

QX-870 Industrial Raster Scanner User Manual

4-9

Page 62

Output Format

Output Format Enable Output Format This is a global enable/disable parameter. Use Set Number of Symbols and Output Phrase to assign symbols for formatting, and Symbol Parse to determine the specific output content for the assigned symbols. On the Output Format tab, check the Enable Output Format box.

4-10

QX-870 Industrial Raster Scanner User Manual

Page 63

Scanner Setup

Set Number of Symbols Number of Symbols determines the number of symbols to which output formatting will apply.

Output Phrase Output Phrase refers to the user-defined Preamble, selected symbols, and Postamble sequence in the read cycle result. Use the Set Number of Symbols spin box to determine the number of symbols to be included in the output phrase.

Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.

Check the Parse boxes beneath the symbols to be formatted.

QX-870 Industrial Raster Scanner User Manual

Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.

4-11

Page 64

Output Format

Symbol Parse Extract

The Extract Range function corresponds to the Start Location and Length parameters in the Format Extract serial command.

Multiple character sequences can be extracted and inserted using Symbol Parse. In this example, the selected extraction range is characters 2-4. The “Sample Symbol” example on the Symbol Parse dialog shows the selected character positions extracted and output as desired. Simultaneously, the data string from the selected symbol is displayed at the bottom left of the Parse Table, followed by the user-defined extracted output.

Output Index Output Index refers to the database entry to be modified with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output. Starting with index # 1, enter either an extract or insert command to begin building the desired output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until the string is built.

Start Location Defines the location within the symbol data where the character extraction will begin. The first character extracted will also be the first character in the sequence displayed in user-defined output.

Length Defines the length (in consecutive characters) that will be extracted and placed in user-defined output. 4-12

QX-870 Industrial Raster Scanner User Manual

Page 65

Scanner Setup

Insert

The Insert process is very similar to the Extract process, except that Insert allows the user to enter characters using the Insert calculator (shown above).

Notice that Extract and Insert share the same Parse Table.

QX-870 Industrial Raster Scanner User Manual

4-13

Page 66

Output Format

4-14

QX-870 Industrial Raster Scanner User Manual

Page 67

5 Scanner Parameters Contents Communication ............................................................................................................................. 5-2 Read Cycle ................................................................................................................................. 5-43 Symbologies ............................................................................................................................... 5-70 I/O Parameters.......................................................................................................................... 5-107 Matchcode ................................................................................................................................ 5-168 Diagnostics ............................................................................................................................... 5-177

This section explains the function and purpose of the Parameters commands in ESP’s tabbed tree controls. Important: Unless otherwise specified, command settings shown in this section are the default settings.

QX-870 Industrial Raster Scanner User Manual

5-1

Page 68

Communication

Communication Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Communication tab to display the Communication tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Communication settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Communication section of Appendix E.

5-2

QX-870 Industrial Raster Scanner User Manual

Page 69

Scanner Parameters

Port Routing The QX-870 features a communication system based on Port Routing instead of traditional, dedicated serial ports. Decisions can be made about the direction and content of communication between ports based on different Data Types. Any available port can be used in any combination. The fundamental concept of Port Routing is that communication design can be based upon Data Types rather than ports. The advantage of this is the ability to map different data types to different ports - the user is no longer limited to a “Host Port” and “Aux Port” for specific types of input and output. Since each port is independent instead of fixed for a particular purpose, the scanner behaves more like a data switch.

Port Routing Advantages • Data can be routed in on one port and out on the same port or a different port like a switch or router. Transparent Mode, Half Duplex Mode, Full Duplex Mode, and Custom Mode. • External Data Routing still follows the “To/From Host/Aux” paradigm. The new capability allows the customer to define the data direction - which port behaves as the “Host Port” and which port behaves as the “Aux Port”. • Only one daisy chain setup required per system. • Minimal configuration required for each port, with similar items grouped together. QX-870 Industrial Raster Scanner User Manual

5-3

Page 70

Communication

RS-232 A The following settings define the basic transmission speeds and digital standards that ensure common RS-232 formatting.

Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.

Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.

Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.