Page 51
Hardware Installation
Multidrop Multidrop networks are used in applications where it is necessary to decode symbols at multiple locations within an industrial process. Scanners are placed at stations located between manufacturing steps, and data from those scanners is directed to a multidrop concentrator before being sent to a host. An example of this type of application is food packaging, in which part number data is collected and tracked throughout the packaging process. The highlighted areas below demonstrate how a multidrop network can be arranged.
QX-870 Industrial Raster Scanner User Manual
3-11
Page 52
Application Examples
Ethernet TCP/IP and EtherNet/IP Ethernet TCP/IP is the standard Ethernet interface used to connect multiple locations in a network, such as computers in an office network. It can also be used to network other communications devices, such as scanners and PLCs on a factory floor. EtherNet/IP™ is a protocol developed and governed by ODVA (Open DeviceNet Vendors Association). It is based on the Common Industrial Protocol (CIP™). The CIP layer is an additional layer within the standard Ethernet interface (Ethernet TCP/IP). EtherNet/IP is common in control systems and PLCs, especially in the United States. The highlighted areas below demonstrate how an Ethernet daisy chain can be arranged. Ethernet-enabled scanners can also be set up in standalone configurations, or multiple Ethernet-enabled scanners along a production or packaging line can be connected to Ethernet.
“EtherNet/IP” and “CIP” are trademarks of the Open DeviceNet Vendors Association.
3-12
QX-870 Industrial Raster Scanner User Manual
Page 53
4 Scanner Setup Contents Calibration..................................................................................................................................... 4-2 Configuration Database ................................................................................................................ 4-4 Ordered Output............................................................................................................................. 4-6 Output Format............................................................................................................................. 4-10
This section describes ESP’s four Setup interfaces: Calibration, Configuration Database, Ordered Output, and Output Format. Each interface allows the user to make changes to scanner configuration quickly and easily.
QX-870 Industrial Raster Scanner User Manual
4-1
Page 54
Calibration
Calibration The settings in the Calibration interface can also be configured using the <@> and <@CAL> serial commands, and the Calibration Options command. The Test and Calibrate features are also available in EZ Mode.
Click Save to save calibration settings, or Stop to cancel the calibration process.
4-2
Top Offset, Bottom Offset, Sweep and other raster functions can be set using the fields below, and top and bottom offset can also be set by clicking and dragging the edges of the laser arc in the picture.
Scan Speed, Gain, Tracking, Laser Power, and Raster Options can also be configured in the Reader Setup command.
QX-870 Industrial Raster Scanner User Manual
Page 55
Scanner Setup
Laser Off Position Percentage of the full scan arc that the scan beam moves through before the laser turns off. The combined values of Laser On Position and Laser Off Position cannot exceed 100 percent, the total arc of one scan. Laser Off Position must always exceed the value of Laser On Position for a scan to take place.
Laser Off Position
Laser On Position Percentage of the full scan arc that the scan beam moves through before the laser turns on. For example, if set to 30, the laser will be off during the first 30 percent of the scan. When Laser Framing is disabled, the laser is on for 100 percent of the full scan.
Laser On Position
QX-870 Industrial Raster Scanner User Manual
4-3
Page 56
Configuration Database
Configuration Database Configuration Database settings can also be configured by using the Configuration Database serial commands.
Double-clicking on an Index will bring up the Configuration Database Settings dialog.
Use the Number of Active Indexes field to determine how many database indexes will be used. Use the Number of Database Cycles to determine how many times the active indexes will be repeated. Use the Switch Timing field to determine the amount of time between active indexes.
4-4
QX-870 Industrial Raster Scanner User Manual
Page 57
Scanner Setup
Configuration Database Settings Double-clicking an Index will bring up the Configuration Database Settings dialog for that database index.
The settings shown above can be configured differently for every active index. Once all active database indexes are configured, the index can be concatenated and cycled for the number of times specified in Number of Database Cycles.
QX-870 Industrial Raster Scanner User Manual
4-5
Page 58
Ordered Output
Ordered Output Output filtering is a method of providing a set of good read qualifiers and also providing ordered output. There is a filter for up to the first 10 positions in a multisymbol output. The first filter corresponds to the first symbol output at the end of the read cycle. Each filter has settings for the following six parameters: Filter Number, Symbology Type, Length, Wildcard, Placeholder, Matching Data, Decode Direction, and Database Number.
Filter Number, Symbology Type, Length, Wildcard, Placeholder, and Matching Data are all displayed in the table below. Double-clicking on any row of the table will display the Ordered Output Filter Settings dialog, where settings can be changed.
Receive settings from the scanner, Send settings to the scanner, or Send and Save settings.
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable output filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 5, then filter indexes 1, 2, 3, 4, and 5 will be applied.
4-6
QX-870 Industrial Raster Scanner User Manual
Page 59
Scanner Setup
Filter Number This is the filter index number that represents the position of the symbol in the data output at the end of the read cycle. This index number should be entered along with the following filter settings for the predetermined symbol position.
Symbology Type Specifies the symbology type allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all the requirements of the selected filter index.
Length Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Wildcard This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Placeholder The placeholder character requires a character to be present, but does not compare the data value.
Matching Data This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”. QX-870 Industrial Raster Scanner User Manual
4-7
Page 60
Ordered Output
Ordered Output Filter Settings
Double-clicking on a row in the Ordered Output table brings up the Ordered Output Filter Settings dialog. Use these settings to determine Symbology Type, Length of the symbol, a user-defined Matching String, ASCII Lookup, Wildcard Character, Placeholder Character, Database Number, and Decode Direction. Click Apply to save the settings to the corresponding filter.
4-8
QX-870 Industrial Raster Scanner User Manual