Page 41
3 Hardware Integration Contents Cordsets ....................................................................................................................................... 3-2 QX-870 and QX-1 Connectors and Pinouts.................................................................................. 3-3 Power and Trigger Switching........................................................................................................ 3-8 Port Routing.................................................................................................................................. 3-9 Application Examples ................................................................................................................. 3-10
This section introduces the details of QX-870 hardware, and explains how that hardware can be integrated in an application.
QX-870 Industrial Raster Scanner User Manual
3-1
Page 42
Cordsets
Cordsets The terms “cordset” and “cable” are both applicable to industrial connectivity, but they are not synonymous. Cordsets enable communications and power between scanners and interface devices. Cordsets have an M12 connector at one or both ends. Examples of cordsets are shown below.
M12 to M12 Cordset
M12 to RJ45 (Ethernet) Cordset
M12 to Photo Sensor Cordset
Cables do not have M12 connectors at either end. An example of a cable is shown below.
Cable with flying leads
3-2
QX-870 Industrial Raster Scanner User Manual
Page 43
Hardware Installation
QX-870 and QX-1 Connectors and Pinouts When deploying a network of scanners and interface devices in an industrial setting, it is important to use components whose pin assignments are arranged in a way that avoids communication errors and equipment damage. This can be achieved with components that are designed in a logical, consistent, and easy-to-implement way. The QX-870 has a very simple pin assignment methodology. The clearly identified connectors at the back of the unit can be used to receive and bus power, and also to send and receive data and commands. QX-870 (Base View) A is a serial M12 12-pin plug on both Serial and Ethernet models. B is a serial M12 12-pin socket on serial models, and an 8-pin socket on Ethernet models.
B
A
P/M is a serial M12 12-pin plug on both Serial and Ethernet models.
P/M
T
T is a 4-pin Micro-Change socket on both Serial and Ethernet models (identical to the QX-1 trigger connector). RS-422/485 TxD (–)
Output 2 Default
New Master
Power
Output 1
RS-232 TxD
Output 3
N/C
N/C
Power
RS-422/485 TxD (+)
N/C RS-422/485 RxD (+) N/C
Trigger Ground
Ground RS-232 RxD
Input Common
RS-422/485 RxD (–)
A (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12
Function Trigger Power Default New Master Output 1 Output 3 Ground Input Common RS-232 (Host) RxD RS-232 (Host) TxD Output 2 Output Common
N/C
N/C
Output Common
Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue
P/M (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12
Function N/C Power N/C N/C 422/485 TxD (+) 422/485 RxD (+) Ground N/C N/C N/C 422/485 TxD (–) 422/485 RxD (–)
Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue
Continued next page QX-870 Industrial Raster Scanner User Manual
3-3
Page 44
QX-870 and QX-1 Connectors and Pinouts
QX-870 and QX-1 Connectors and Pinouts (continued) RS-422/485 RxD (–) Input Common
RS-232 TxD/ RS-232 RTS Trigger
Ground
RS-232 RxD/ RS-232 CTS
RS-422/485 RxD (+)
Power
RS-422/485 TxD (+)
TX (+)
Terminated
RX (–)
RX (+) Terminated
Terminated
Input 1
TX (–)
RS-422/485 TxD (–)
Terminated
B (Serial Models) M12 12-pin Socket Pin 1 2 3 4 5 6 7 8 9 10 11 12
Terminated
Function Trigger Power Terminated Input 1 Port 3 422/485 TxD (+) Port 3 422/485 RxD (+) Ground Input Common Port 2 TxD/Port 1 RTS Port 2 RxD/Port 1 CTS Port 3 422/485 TxD (–) Port 3 422/485 RxD (–)
Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue
B (Ethernet Models) M12 8-pin Socket Pin 1 2 3 4 5 6 7 8
Function Terminated Terminated Terminated Port 4 TX (–) Port 4 RX (+) Port 4 TX (+) Terminated Port 4 RX (–)
Trigger
+10-28V
Ground
Trigger/New Master / Input 1 Common
Connector T (Trigger) 4-pin Socket Pin 1 2 3 4
3-4
Function + 10-28V Trig/NM/Input 1 Common Ground Trigger
QX-870 Industrial Raster Scanner User Manual
Page 45
Hardware Installation
QX-1 Interface Device The QX-1 Interface Device’s receptacles are physically the same as those on the QX-870, but they do not have explicit pin assignments. The QX-1 allows users to bus power and communications as required by the application. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. 1, 3 1,3, T
PWR TRIG
1,2, 3 1,2, 3, T
QX-1 Interface Device Pin 1 2 3 4
Function + 10-28V Trig/NM/Input 1 Common Ground Trigger
QX-1 Trigger Connector 4-pin Socket This simple diagram (shown on the base of the QX-1) illustrates how power, communications, I/O, and trigger signal can be routed through the QX-1 device depending on the needs of the application. The switches greatly increase signal routing flexibility.
QX-1 Communications - I/O Power - Trigger
QX-870 Industrial Raster Scanner User Manual
3-5
Page 46
QX-870 and QX-1 Connectors and Pinouts
Grounding the QX-870 Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
An earth ground is provided through the cable shields and chassis of the scanner.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.
3-6
QX-870 Industrial Raster Scanner User Manual
Page 47
Hardware Installation
Expected Power and Ground Connections for Proper Operation
Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.
QX-870 Industrial Raster Scanner User Manual
3-7
Page 48
Power and Trigger Switching
Power and Trigger Switching
1, 3 1,3, T
3-8
PWR TRIG
1,2, 3 1,2, 3, T
Power can be bussed between scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the QX-1 can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required by the application.
QX-870 Industrial Raster Scanner User Manual
Page 49
Hardware Installation
Port Routing The physical advantages created by flexible signal routing and switching are enhanced further by Port Routing, which can be configured in ESP. Port Routing eliminates the need for dedicated “Host” and “Aux” ports in a traditional sense. With Port Routing, any port can be defined as a Host or Aux port. Port Routing also allows users to define the data types that are accessible from specific ports. The primary benefit of Port Routing is that any type of data can be routed to any port, and can be sent through multiple ports simultaneously. Multiple types of data can also be appended to the symbol data that is output from the scanner to the host. Command data, symbol data, extra symbol information, and diagnostic data are enabled by default in the QX-870. The table below lists different types of data, with examples for each data type. Data Type
Example
Command Data
Serial commands; scanner responses to serial commands.
Symbol Data
Any string of data encoded in a symbol.
Extra Symbol Information
Decodes per trigger, decode direction, configuration database index number.
Diagnostic Data
Laser status, temperature, service message.
The screen capture below (from ESP) shows the QX-870’s four communications ports and the parameters for each.
RS-232 A, RS-232 B, and RS-422 are serial. RS-232 A is always enabled. RS-232 B and RS-422 can be enabled or disabled to match the physical requirements of the application. Ethernet can also be enabled or disabled as required. RS-232 A, RS-232 B, and RS-422 can be configured for Baud Rate, Parity, Stop Bits, Data Bits, Symbol Data Output, Extra Symbol Information (Decodes Before Output, Symbol Position Output, etc.), Diagnostics Output, and External Source Processing Mode (Command or Data). Ethernet can be configured for IP Address, Subnet Mask, Gateway, IP Address Mode (Primary or Secondary TCP Port), Symbol Data Output, Extra Symbol Information, Diagnostics Output, and External Source Processing Mode.
QX-870 Industrial Raster Scanner User Manual
3-9
Page 50
Application Examples
Application Examples The following examples demonstrate how the components described in previous pages can be deployed in industrial applications.
Daisy Chain Daisy chain configurations are used in applications such as product packaging, where single items have multiple symbols. For example, a box with one symbol on the top and symbols on either side requires at least three scanners to ensure that all symbols will be decoded. The highlighted areas below demonstrate how a daisy chain can be arranged. One scanner is placed above the conveyor line and one scanner is placed on each side of the line. The three scanners essentially function as a single scanner, and data is sent from the primary scanner to the host or PLC. Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanners in the daisy chain.
3-10
QX-870 Industrial Raster Scanner User Manual