Page 81

Scanner Parameters

Subnet Enter the Subnet address of the scanner in this field.

QX-870 Industrial Raster Scanner User Manual

5-15

Page 82

Communication

Gateway Enter the Gateway address of the scanner in this field.

5-16

QX-870 Industrial Raster Scanner User Manual

Page 83

Scanner Parameters

IP Address Mode Determines how the scanner’s IP address will be defined.

Static In Static Mode, the scanner uses the user-defined IP address entered in ESP.

DHCP In DHCP Mode, the scanner automatically acquires the IP address, Subnet, and Gateway addresses from a DHCP or BOOTP server.

QX-870 Industrial Raster Scanner User Manual

5-17

Page 84

Communication

TCP Port 1 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2001.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 1 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.

5-18

QX-870 Industrial Raster Scanner User Manual

Page 85

Scanner Parameters

TCP Port 2 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2003.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 2 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.

QX-870 Industrial Raster Scanner User Manual

5-19

Page 86

Communication

EtherNet/IP Enables or disables EtherNet/IP operation in the scanner. Important: See Appendix H, Using EtherNet/IP, for detailed information about implementing EtherNet/IP in an application.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables EtherNet/IP as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. 5-20

QX-870 Industrial Raster Scanner User Manual

Page 87

Scanner Parameters

Protocol Selection In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communication standards. Protocols define the sequence and format in which information is transferred between the scanner and the host, or in the case of Multidrop, between the scanners and a concentrator. Note: In all protocol modes, the Preamble and Postamble character strings can be used to frame the decoded data, and both are included in calculating the LRC (Longitudinal Redundancy Check).

QX-870 Industrial Raster Scanner User Manual

5-21

Page 88

Communication

Protocol Options

Point-to-Point (Standard) Used only with RS-232 or RS-422. Standard Point-to-Point requires no address and sends the data to the host whenever it is available, without a request or handshake from the host.

Point-to-Point with RTS/CTS A scanner initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. RTS and CTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS-232. Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshake protocol that allows a scanner to initiate data transfers to the host.

Point-to-Point with XON/XOFF If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices. Used only with RS-232. This option enables the host to send the XON and XOFF command as a single byte transmission command of start (^Q) or stop (^S).

Point-to-Point with RTS/CTS and XON/XOFF Used only with RS-232. This option is a combination of Point-to-Point with RTS/CTS and Point-to-Point with XON/XOFF.

ACK/NAK See ACK / NAK Options.

Polling Mode See Polling Mode Options.

5-22

QX-870 Industrial Raster Scanner User Manual

Page 89

Scanner Parameters

Address The Protocol Address can be any number between 1 and 50.

Protocol Port RS-232 A or RS-422 can be used as Protocol Ports.

QX-870 Industrial Raster Scanner User Manual

5-23

Page 90

Communication

ACK / NAK Options These parameters take effect for ACK/NAK on the main RS-232 or RS-422 ports (not on the Auxiliary Port), and are completely independent of the Polling Mode Options. The scanner always follows the protocol in both directions (to and from the host). There is no option to disable it from either direction.

RES-NAK Defaults RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)

5-24

NUL (0x00) NUL (0x00) NUL (0x00) NUL (0x00) ACK (0x06) NAK (0x15)

QX-870 Industrial Raster Scanner User Manual