Page 411

Appendices • Click the Next button.

• Click the Next button.

QX-870 Industrial Raster Scanner User Manual

A-125

Page 412

Allen-Bradley Version 20 PLC Setup • Click the Next button.

• Click the Finish button.

A-126

QX-870 Industrial Raster Scanner User Manual

Page 413

Appendices • Now the EDS file has been loaded into RSLogix’s database. Right-click the Ethernet menu item and select New Module.

• To find your camera in the list, type fis and the dialog will show only devices with the letters “fis” in the name. Either double-click the camera you want or highlight it and click the Create button.

QX-870 Industrial Raster Scanner User Manual

A-127

Page 414

Allen-Bradley Version 20 PLC Setup • Enter the name of the device used in the PLC program and the IP address of the camera.

• After the new device has been added to the project, the default assembly data will be the small size. You can change it to large by double-clicking the camera menu item in the tree control and clicking the Change button on the dialog.

A-128

QX-870 Industrial Raster Scanner User Manual

Page 415

Appendices • Select the large assembly size and click the OK button when done.

QX-870 Industrial Raster Scanner User Manual

A-129

Page 416

EIPScan Setup

Appendix N, EIPScan Setup This procedure is for the EIPScan simulation tool published by Pyramid Solutions. 1. Right-click on EIPScan Test Tool and select Add Device.

2. Set the IP Address to match the QX-870.

A-130

QX-870 Industrial Raster Scanner User Manual

Page 417

Appendices The QX-870 will appear in the main window.

3. Right-click on QX-870 and select Add Class1 Connection.

QX-870 Industrial Raster Scanner User Manual

A-131

Page 418

EIPScan Setup 4. When the Add Class1 Connection dialog appears, select Data Size. 5. Populate Originator->Target (OUT) with 12, and Target->Originator (Big IN) with 176.

Alternately, Target->Originator could be set to 84 for the Small IN assembly. 6. Select Rate and set packet rate to 20 milliseconds in both directions.

A-132

QX-870 Industrial Raster Scanner User Manual

Page 419

Appendices 7. Select Destination. 8. Populate Originator->Target (OUT) with 198, and Target->Originator (Big IN) with 101.

Alternately, Target->Originator could be set to 100 for the Small IN assembly. 9. Click OK and the IO data windows will appear in the main area. 10. In the I/O menu, select Run mode so that there is a check mark next to it.

QX-870 Industrial Raster Scanner User Manual

A-133

Page 420

EIPScan Setup EIPScan begins polling the unit, and displays the content of the IN (blue) and OUT (green) assemblies.