Page 421

Appendices 12. Change the first byte to non-zero. The first byte (User Tag echo) in the blue area (IN) will change to the same value.

All bytes in the green OUT area will be echoed back in the blue IN area, at the same location relative to the beginning of the assemblies. Each byte, and bit, has a unique purpose. Please consult the object model for a description. Note that all data is displayed in little-endian order.

QX-870 Industrial Raster Scanner User Manual

A-135

Page 422

Interface Standards

Appendix O, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. In the QX-870, selection of interface is made by pin assignment and, in the case of host communication, by software switching between RS-232 and RS-422/RS-485.

RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

RS-422/RS-485 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.

Ethernet TCP/IP and EtherNet/IP TCP/IP and EtherNet/IP protocols are supported over Ethernet. A 6-byte hardware address is used, which is divided into a 3-byte vendor ID and a 3-byte vendor-defined field. Ethernet-enabled device manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.

A-136

QX-870 Industrial Raster Scanner User Manual

Page 423

Appendices

Appendix P, Glossary of Terms AGC, See Automatic Gain Control. Analog, A smooth, continuous voltage or current signal or function whose magnitude (value) is the information. Automatic Gain Control (AGC), Adjustment to signal strength that seeks to maintain a constant level regardless of the distance between a scanner and symbol. Baud Rate, The number of discrete signal events per second; bits per second. Check Character, A Modulus 43 or Modulus 10 character that is added to encoded symbol data for additional data integrity. Connector, A plug or socket on a device or cable providing in/out connectivity for various circuits and pins. Concentrator, Intermediary device that relays data from scanners to a host and commands from the host to the scanners or other devices. Counter, Memory space allocated to keep track of scanner events. Daisy Chain, Linkage of primary and secondary scanners allowing data to be sent to the host. Decode, A good read. The successful interpretation and output of the information encoded in a symbol. Default, Restores non-volatile or flash memory settings, initializes serial commands, and resets all counters. Delimited, A delimited command or field is bracketed by predefined characters. Decode Rate, The number of good reads per second ahieved by a scanner. Discrete I/O, Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. End of Read Cycle, The time or condition at which the scanner stops expecting symbol information to decode. External Edge, Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object. The read cycle ends with a good read, a timeout, or a new trigger. External Level, Allows a read cycle to be initiated by a trigger signal from a photo sensor. The read cycle ends when the object moves out of the detector’s range. Firmware, Software hard-coded in non-volatile memory and closely tied to specific pieces of hardware. Fixed Symbol Length, Increases data integrity by ensuring that only one symbol length will be accepted. Full Duplex, A communication system in which signals can travel simultaneously between devices. Gain, Optimal signal strength. Good Read, A decode. The successful scanning and decoding of the information encoded in a symbol.

QX-870 Industrial Raster Scanner User Manual

A-137

Page 424

Glossary of Terms Half Duplex, A communication system in which signals can travel between devices in both directions, but not simultaneously. Host, A computer, PLC, or other device that is used to execute commands and process data and discrete signals. Initialize, Implement serial configuration commands into the scanner’s active memory. Input, A channel or communication line. Decoded data or a discrete signal that is received by a device. Ladder Orientation, A linear symbol orientation in which the bars are parallel to the symbol’s direction of travel. LED, See Light-Emitting Diode. Light-Emitting Diode (LED), A semiconductor device that emits light when conducting current. Multidrop, A communication protocol for networking two or more scanners or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Noise, The same as static in a phone line or “snow” in a television picture, noise is any unwanted electrical signal that interferes with the symbol data being decoded and transmitted by the scanner. Normally Closed, A discrete output state that is only active when open. Normally Open, A discrete output state that is only active when closed. Output, A channel or communication line. Data or discrete signals that are transmitted or displayed by a device. Parity, An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Picket Fence Orientation, A linear symbol orientation in which the bars are perpendicular to the symbol’s direction of travel. Pitch, Rotation of a symbol around an axis parallel to the symbol length on the substrate. PLC, See Programmable Logic Controller. Port, Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Programmable Logic Controller (PLC), An electronic device used in industrial automation environments such as factory assembly lines and automotive manufacturing facilities. Protocol, The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Read Cycle, A programmed period of time or condition during which a scanner will accept symbol input. Skew, Rotation of a symbol around an axis parallel to the symbol height on the substrate. Substrate, The surface upon which a symbol is printed, stamped, or etched. Symbol Transitions, The transition of bars and spaces on a symbol, used to detect the presence of a symbol on an object.

A-138

QX-870 Industrial Raster Scanner User Manual

Page 425

Appendices Symbology, A symbol type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Tilt, Rotation of a symbol around an axis perpendicular to the substrate. Trigger, A signal, transition, or character string that initiates a read cycle. Very Large-Scale Integration (VLSI), The creation of integrated circuits by combining thousands of transistor-based circuits on a single chip.

QX-870 Industrial Raster Scanner User Manual

A-139

Page 426

Glossary of Terms

A-140

QX-870 Industrial Raster Scanner User Manual