Page 251

6 Terminal Contents Terminal Window.......................................................................................................................... 6-2 Find .............................................................................................................................................. 6-3 Send ............................................................................................................................................. 6-4 Macros.......................................................................................................................................... 6-5 Terminal Window Menus.............................................................................................................. 6-6

This section describes the multiple functions of ESP’s Terminal interface.

QX-870 Industrial Raster Scanner User Manual

6-1

Page 252

Terminal Window

Terminal Window Click this button to display the Terminal view. Copy, paste, save

Clear screen

Macros listed on this bar

Type text here to find matching text in the Terminal window.

Terminal screen

Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.

Type serial commands here.

Click on desired Macro to run.

The Terminal interface allows the user to send serial commands to the scanner by using macros, by copying and pasting, or by typing commands in the Send text field. The Terminal also displays symbol data or information from the scanner. Right-clicking on the Terminal screen displays a menu of additional options.

6-2

QX-870 Industrial Raster Scanner User Manual

Page 253

Terminal

Find The Find function allows the user to enter text strings to be searched for in the Terminal. For example: 1. Type “ABC” into the Find box.

2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.

QX-870 Industrial Raster Scanner User Manual

6-3

Page 254

Send

Send The Send function allows the user to enter serial commands and then send them to the scanner. 1. Type the command into the Send box.

2. Press Enter. 3. Click the Send button to the left of the text field to send the command additional times.

6-4

QX-870 Industrial Raster Scanner User Manual

Page 255

Terminal

Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.

Click on Next Row to see the next row of macros

Click on the first arrow here to see Add Macro or Default Macros. When macros are defaulted, the entire macro set is restored to the original macro commands.

Click on subsequent arrows to edit macros.

Click a macro button to execute it in the Terminal. If the macro is a command, it is sent to the scanner at the same time that it is displayed.

Editing a Macro Click the arrow next to any macro and select Edit to display the following dialog:

Edit the macro value or type a new Macro Name in the text field provided and define it in the Macro Value field. Click OK to save the entry.

QX-870 Industrial Raster Scanner User Manual

6-5

Page 256

Terminal Window Menus

Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows the user to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all the above settings to default. • Keyboard Macros allows the user to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)

Terminal Dropdown Menu The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... allows the user to append data in real time to a text file. While in operation, the text file cannot be opened. Pause interrupts the capture flow and Stop ends the flow and opens the file. • Save Current Text... saves all text in the Terminal window to a text file. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.

6-6

QX-870 Industrial Raster Scanner User Manual

Page 257

7 Utilities Contents Serial Utility Commands ............................................................................................................... 7-2 Read Rate .................................................................................................................................... 7-4 Counters ....................................................................................................................................... 7-6 Device Control .............................................................................................................................. 7-8 Differences from Default............................................................................................................... 7-9 Master Database ........................................................................................................................ 7-10 Digital Bar Code ......................................................................................................................... 7-16 Firmware..................................................................................................................................... 7-17 Default/Reset/Save..................................................................................................................... 7-20 Scanner Status Requests........................................................................................................... 7-22 Other Serial Utility Commands ................................................................................................... 7-23 Embedded Menus ...................................................................................................................... 7-28

This section explains the function and purpose of serial utility commands, which are generally performed during scanner operation.

QX-870 Industrial Raster Scanner User Manual

7-1

Page 258

Serial Utility Commands

Serial Utility Commands Note: For a list of all K commands, see Serial Commands. Type Read Rate

Counters

Device Control

Master Database

Part Number / Checksum

Command <C> <Cp> <J> <a1> <N> <O> <T> <U> <V> <W> <X> <Y> <L1> <L2> <L3> <I> <H> <G> <Gn> <NEWM> <#> <#a> <#b> <#f> <!> <!a> <!b> <!f> <Z> <Zc>

Default/Reset/Save

<Zrc> <Zrd>

7-2

Name Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests PDF417 Information No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display FPGA Code Part Number Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display FPGA Code Checksum Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On Recall Customer Default Settings and Save for Power-On Recall Microscan Default Settings and Save for Power-On (Will not default “sticky settings”)

QX-870 Industrial Raster Scanner User Manual

Page 259

Utilities

<A> <Arp> <Arc> <Ard> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <D> <@CAL> <@> <BCCFG>

Recall Microscan Default Settings and Save for Power-On (Will also default “sticky settings”) Reset (Will not save for power-on) Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Reset and Recall Microscan Default Parameters All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Default Customer Parameter Enter Embedded Menus Calibrate without Menu Calibrate with Menu Enter Bar Code Configuration

QX-870 Industrial Raster Scanner User Manual

7-3

<Zrdall> Default/Reset/Save

Scanner Status Request Commands

Embedded Menus Other Serial Utility Commands

Page 260

Read Rate

Read Rate Click the Utilities button and then the Read Rate tab to display the Read Rate view.

To see the number of decodes per second, click the Decodes/sec radio button and then the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. Read Rate information is displayed in the lower portion of the Utilities view. Serial commands can also be sent to the scanner from this screen.

To end a Read Rate test, click the Stop button (the Start button becomes a Stop button during an active Read Rate test.)

Important: When Read Rate is enabled, the Configuration Database is not active, regardless of how the scanner is configured.

7-4