Page 241

Scanner Parameters

Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.

Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.

Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.

Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.

QX-870 Industrial Raster Scanner User Manual

5-175

Page 242

Diagnostics

Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Matchcode settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Diagnostics section of Appendix E.

5-176

QX-870 Industrial Raster Scanner User Manual

Page 243

Scanner Parameters

Counts (Read-only)

Power-On 16-bit counter that increments on scanner power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Returns the number of times the scanner has been re-powered or a watchdog reset occurs. 0 to 65,535 power-ons.

Resets 16-bit counter that increments every time the scanner is reset. Value is reset on power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware defaults. A watchdog reset is a reset that is forced whenever the software locks up. 0 to 65,535 resets.

Power-On Saves 16-bit counter that increments every time a scanner setting is saved for power-on.

Custom Default Saves 16-bit counter that increments every time a scanner setting is saved to the customer parameter section of flash memory.

QX-870 Industrial Raster Scanner User Manual

5-177

Page 244

Diagnostics

Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.

Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.

Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.

5-178

QX-870 Industrial Raster Scanner User Manual

Page 245

Scanner Parameters

Laser High When Enabled, a Laser High message is transmitted whenever the laser current exceeds a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Microscan Service.)

Status Allows the user to Enable or Disable the Laser High message.

Message Defines the Laser High message.

QX-870 Industrial Raster Scanner User Manual

5-179

Page 246

Diagnostics

Laser Low When Enabled, a Laser Low message is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Microscan Service.)

Status Allows the user to Enable or Disable the Laser Low message.

Message Defines the Laser Low message.

5-180

QX-870 Industrial Raster Scanner User Manual

Page 247

Scanner Parameters

High Temperature Threshold A message can be defined that will display when a user-defined High Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner. Helps ensure that the scanner is being used within its temperature specification. Also, since hotter environments tend to shorten the life of electronics components, a user may want to set the temperature threshold closer to the nominal temperature of 25° F. A user can set a temperature value that when exceeded will cause a high temperature message to be displayed. If High Temperature Threshold is set to zero, the warning message is disabled.

Status Allows the user to Enable or Disable the High Temperature Threshold.

Message The user can enter a message of up to 10-characters that will be displayed whenever High Temperature Threshold is exceeded.

QX-870 Industrial Raster Scanner User Manual

5-181

Page 248

Diagnostics

Low Temperature Threshold A message can be defined that will display when a user-set Low Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner. Helps ensure that the scanner is being used within its temperature specification. The user can set a low temperature value that, whenever the ambient temperature falls below it, causes a low temperature message to be displayed. If Low Temperature Threshold is set to zero, the warning message will be disabled.

Status Allows the user to Enable or Disable the Low Temperature Threshold.

Message The user can enter a message of up to 10-characters that will be displayed whenever the ambient temperature falls below the Low Temperature Threshold.

5-182

QX-870 Industrial Raster Scanner User Manual

Page 249

Scanner Parameters

Service Message Status When Enabled, a Service Message of up to 128 characters is sent whenever the system detects that the service time has expired.

Service Message Allows the user to define a service message of up to 128 characters.

Threshold Allows the user to determine the length of time until the service message will be sent.

Resolution The service timer has a resolution field for setting up the timer increment. Options are increments of seconds or minutes.

QX-870 Industrial Raster Scanner User Manual

5-183

Page 250

Diagnostics

User-Defined Name User-Defined Name allows the user to enter any combination of ASCII characters to identify the scanner.

5-184