Page 261

Utilities

Read Rate Serial Utility Commands Enter Decodes / Second Test Sending <C> instructs the scanner to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the scanner during setup.

Enter Decode Percent Test Sending <Cp> instructs the scanner to transmit the percentage of decodes and any decoded symbol data.

End Decodes / Second and Decode Percent Tests Sending <J> ends both the Percent test and the Decodes/Second test.

PDF417 Information Sending <a1> causes PDF417 data that is decoded in a triggered read cycle to be prefaced with information about the symbol’s level of error correction (error correction level n), number of rows (n rows), number of columns (n columns), number of informative code words (n code words), and number of data bits (n data bits). This feature can be disabled by sending <a1> again.

QX-870 Industrial Raster Scanner User Manual

7-5

Page 262

Counters

Counters Click the Utilities button and then the Counters tab to display the Counters view. Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter will automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the scanner does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the scanner, or if the scanner receives a Reset or Save command. Click the Request button to display the appropriate count or Clear to set the counter to zero.

Trigger, Good Read, No Read, and Mismatch counters can be requested and cleared simultaneously (Request All and Clear All buttons) or individually (Request and Clear buttons to the left of each item).

7-6

QX-870 Industrial Raster Scanner User Manual

Page 263

Utilities

Counters Serial Utility Commands No Read Counter Sending <N> displays the total number of No Reads that have occurred since the last reset.

No Read Counter Reset Sending <O> sets the No Read Counter to 00000.

Trigger Counter Sending <T> displays the total number of triggers since the last reset.

Trigger Counter Reset Sending <U> sets the trigger counter to 00000.

Good Read / Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master symbol, or, if Master Symbol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this counter records the number of good reads. This count can be requested at any time.

Good Read / Match Counter Reset Sending <W> sets the Match Counter to 00000.

Mismatch Counter Sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.

Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.

QX-870 Industrial Raster Scanner User Manual

7-7

Page 264

Device Control

Device Control Click the Utilities button and then the Device Control tab to display the Device Control view.

The Output 1 Pulse, Output 2 Pulse, and Output 3 Pulse buttons activate the link between the + and – of the host connector. The buttons in the Extras section can Disable or Enable the reader, or deactivate and reactivate the motor.

Device Control Serial Utility Commands Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector (regardless of Master Symbol or Output 1 status).

Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector (regardless of Master Symbol or Output 2 status).

Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector (regardless of Master Symbol or Output 3 status).

Disable Reader Sending <I> will turn the scanner OFF, end the current read cycle, and will not allow the scanner to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the scanner is being configured. Disabling the scanner will not affect any commands that have already been downloaded.

Enable Reader Sending <H> will turn the scanner ON and allow it to enter read cycles.

7-8

QX-870 Industrial Raster Scanner User Manual

Page 265

Utilities

Differences from Default Click the Utilities button and then the Differences tab to display the Differences from Default view. Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.

Click Generate Barcode to display the Bar Code Dialog. Then create configuration symbols containing the required configuration commands.

Send configuration settings to the scanner without saving by clicking Send to Reader.

Click Save As to save the report as plain text or a tab-delimited text file.

Send configuration settings to the scanner and save in ESP by clicking Send and Save.

• To create a symbol containing any of the command settings in the table, click Generate Barcode. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the scanner and save them, or Send to Reader to send the settings without saving them. Important: To use Differences from Default, connect to the scanner and Receive Reader Settings via the Send/Recv button on the toolbar. QX-870 Industrial Raster Scanner User Manual

7-9

Page 266

Master Database

Master Database Click the Utilities button and then the Master Database tab to display the Master Database view. Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.

Master Database Overview Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands. 1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which the master symbol will be entered. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.

Loads the next symbol decoded into the selected index.

Saves the database to the scanner. Loads the scanner’s saved master symbols into ESP.

Double-click a row to enter data into popup text box.

7-10

QX-870 Industrial Raster Scanner User Manual

Page 267

Utilities

Master Symbol Database Size Master Symbol Database Size allows the user to select 1 to 10 master symbols for the master symbol database.

Set Master Symbol Database Size here.

Important: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5 #6 #7 #8 #9 # 10

Maximum Characters 3000 1500 1000 750 600 500 428 375 333 300

QX-870 Industrial Raster Scanner User Manual

7-11

Page 268

Master Database

Enter Master Symbol Data Allows the user to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Enter data for 1 to 10 master symbols. Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols to be created in Master Symbol Database Size. 3. Double-click on each master symbol number in the table, type master symbol data in the popup dialog that appears, and click OK. 4. When all master symbol data has been entered, click the Send Database to the Reader button.

Enter master symbol data in this field.

7-12

QX-870 Industrial Raster Scanner User Manual

Page 269

Utilities

Request Master Symbol Data Returns master symbol data for any enabled master symbols from 1 to 10. 1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.

Read Next Symbol as Master Symbol After the size of the database is set, the scanner can read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab, 1. Select the master symbol index number in which new symbol data will be stored. 2. Click the Read Symbol into Selected Index button.

Caution: If an index with existing data is selected, that data will be overwritten by the new decoded data when this command is used.

QX-870 Industrial Raster Scanner User Manual

7-13

Page 270

Master Database

Request New Master Status Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. Send the <NEWM> command from ESP’s Terminal. The scanner returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.

7-14

QX-870 Industrial Raster Scanner User Manual