Operations Menu
Match Start Position
Match Length Default: 1 Options: 1 to 31 Defines the length of the character string that will be compared with that of the master label when Match Code Type is set to Enabled or Sequential and Match Start position is set to 1 or greater. For example, If Match Length is set to 6 in a 10 character label, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared.
Wild Card Character Default: * (asterisk) Options: Any ASCII character Allows you to define the wild card character that can be used when defining a master label. Master Label Entry With Match Code Type set to Enabled, Sequential, or Wild Card, a master label can be entered in four ways: 1. By typing in from the keyboard at the command line of the Operations menu under Match Code Master. 2. With New Master Pin enabled (see page 2-34), toggling scanner pin 12 to ground (or by momentarily pressing the New Master button on the IB105) will save the next label read as the master label. 3. Sending serial command <G> allows the next label read to be the master label. 4. Sending a serial command in the format <)XXXX)> downloads data as the master label.
MS-7100/7180 Industrial Scanner User’s Manual
2-21
2–Menu Config.
Default: 0 Options: 0 to 31 Match Start Position must be set to 1 or greater to enable this feature. Defines the first character in the label (from left to right) that will be compared with those of the master label when Match Code Type is set to Enabled or Sequential. For example, if you set Match Start Position to 3, the first 2 characters read in the label will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.
Page 52
Chapter 2
Menu Configuration
Code Types Menu The Code Types menu allows you to choose among five bar code types and define their parameters, as shown in figure 2-61. Code Types
–
Bold text represents default settings.
2–Menu Config.
Narrow Margins – Disabled – Enabled Symbology Identifier – Disabled – Enabled Code 39 - Status – Enabled – Disabled - Check Digit – Disabled – Enabled - Check Digit Output – Disabled – Enabled - Large Interchar Gap – Disabled – Enabled - Fixed Code Length – Disabled – Enabled - Code Length – 10 – User Definable (1 to 31)
Codabar - Status – Disabled – Enabled - Start & Stop Match – Enabled – Disabled - Start & Stop Output – Enabled – Disabled - Large Interchar Gap – Disabled – Enabled - Fixed Code Length – Disabled – Enabled - Code Length – 10 – User Definable (1 to 31)
UPC I 2 of 5 - Status - Status – Disabled – Disabled – Enabled – Enabled - EAN - Check Digit – Disabled – Disabled – Enabled – Enabled - Supplementals - Check Digit Output – Disabled – Enabled – Disabled – Required – Enabled - Code Length #1 - Separator – Enabled – 10 – Disabled – User Definable - Separator (even, 0 to 30) – , (comma) - Code Length #2 – User Definable – 6 (ASCII char.) – User Definable (even, 0 to 30)
Code 128 - Status – Disabled – Enabled - Fixed Code Length – Disabled – Enabled - Code Length – 10 – User Definable (1 to 31) - UCC/EAN-128 – Status – Disabled – Enabled
– Required
–
Format
–
Ap. Rec. Sep.
–
Ap. Rec. Sep.
–
Ap. Rec. Brackets
–
Ap. Rec. Padding
– Standard – Ap. Rec.
– Disabled – Enabled
– , (comma)
– User Definable – Disabled – Enabled
– Disabled – Enabled
Figure 2-6 Code Types Menu Structure
Options can be defined for any bar code type whether or not the bar code itself is enabled at the time. 1. Options listed in the command line appear in a different order than those posted in the first column of the Code Types menu
2-22
MS-7100/7180 Industrial Scanner User’s Manual
Page 53
Code Types Menu
Narrow Margins Default: Disabled Options: Disabled, Enabled Allows the scanner to read bar codes with quiet zones less than 10 times the narrow-bar-width. Quiet zone is a term used to describe the minimum space at the leading and trailing ends of a label. Each quiet zone can be as small as five times the narrow bar element when Narrow Margins is enabled.
Default: Disabled Options: Disabled, Enabled When enabled, the scanner reads and outputs a three character prefix: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, F, I, E, or C A = Code 39; F = Codabar; I = I 2 of 5; E = UPC/EAN; C = Code 128 3. A single number indicating the status of the check digit character (table 2-1): If check digit is not enabled, the output is 0 (col. 1). If check digit and check digit output are enabled, the output is as shown in column 2. If check digit is enabled, but output is disabled (col. 3), the output is as shown in col. 4, which is the sum of col. 2 and col. 3. Table 2-1 Symbology Identifier Option Values
Column 1 No check character
Column 2
Column 3
Check digit and Check digit output enabled output disabled
Column 4 Sum of Column 2 and 3
Code 39
0
1
(2)
3
Codabar
0
2
(4)
6
I 2 of 5
0
1
(2)
3
UPC/EAN Code 128
Always zero, do not follow AIM spec.
Example 1: For Code 39, if check digit and check digit output are both enabled, a 1 will be output; but if check digit output is disabled, a 3 (the sum of column 2 and column 3) will be output. Example 2: For Codabar, if check digit and check digit output are both enabled, a 2 will be output; but if check digit output is disabled, a 6 (the sum of 2 and 4) will be output.
MS-7100/7180 Industrial Scanner User’s Manual
2-23
2–Menu Config.
Symbology ID
Page 54
Chapter 2
Menu Configuration
Code 39 Status Default: Enabled Options: Enabled, Disabled
Check Digit 2–Menu Config.
Default: Disabled Options: Disabled, Enabled Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial trigger option enabled (see “Triggering Mode” on page 2-13) an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.
Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.
Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Fixed Code Length Default: Disabled Options: Disabled, Enabled Used to increase data integrity by ensuring that only label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length (page 2-24) must be enabled for Code Length to take effect.
2-24
MS-7100/7180 Industrial Scanner User’s Manual
Page 55
Code Types Menu Allows you to specify the exact number of characters that the scanner will recognize. Any code not having the prescribed length will be ignored by the scanner. Available only when Fixed Code Length is enabled.
Codabar Status 2–Menu Config.
Default: Disabled Options: Disabled, Enabled
Start & Stop Match Default: Enabled Options: Enabled, Disabled Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.
Start & Stop Output Default: Enabled Options: Enabled, Disabled Allows the start and stop characters to be transmitted with bar code data.
Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Fixed Code Length Default: Disabled Options: Disabled, Enabled Used to increase data integrity by ensuring that only label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Allows you to specify the exact number of characters that the scanner will recognize. Any code not having the prescribed length will be ignored by the scanner. Available only when Fixed Code Length is enabled.
MS-7100/7180 Industrial Scanner User’s Manual
2-25
Page 56
Chapter 2
Menu Configuration
Interleaved 2 of 5 Status
2–Menu Config.
Default: Disabled Options: Disabled, Enabled Because I 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity.
Check Digit Default: Disabled Options: Disabled, Enabled I 2 of 5 uses a Modulus 10 check digit.
Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.
Code Length #1 Default: 10 Options: 0 to 30, even (If you enter an odd number the scanner will use the next lower number.) With I 2 of 5, two code lengths can be defined. When using only one label length in an application, we recommend setting Code Length #2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count.
Code Length #2 Default: 6 Options: 0 to 30, even. (If you enter an odd number the scanner will use the next lower number.) If using a second label, you may also specify a zero or any even code length from 2 to 30. If not using a second label, set Code Length #2 to 0 to ensure data integrity.
2-26
MS-7100/7180 Industrial Scanner User’s Manual
Page 57
Code Types Menu
UPC Status Default: Disabled Options: Disabled, Enabled When enabled, the scanner will read UPC version A and UPC version E only.
EAN
Supplementals Default: Disabled Options: Disabled, Enabled, Required Note: Narrow Margins must be enabled if the gap between the standard code and the supplemental code is between 5:1 and 10:1 (in relation to narrow-bar-width). Allows the scanner to read supplemental bar code data that has been appended to the standard UPC or EAN codes. When in Required mode, supplemental and bar code label data are treated as a single label, and supplemental data must be found or a noread will result. When set to Enabled, the scanner treats the supplemental data and the bar code label as separate labels.
Separator Default: Enabled Options: Enabled, Disabled Allows you to insert a character between the standard UPC or EAN code and the supplemental code.
Separator (character) Default: , (comma) Options: Any ASCII character Allows you to change the separator character from a comma to a new value.
MS-7100/7180 Industrial Scanner User’s Manual
2-27
2–Menu Config.
Default: Disabled Options: Disabled, Enabled Note: UPC must also be enabled for EAN to take effect. When EAN is enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It will also append a leading zero to UPC version A label information and transmit 13 digits. If you do not want to transmit 13 digits when reading UPC version A labels, disable EAN.
Page 58
Chapter 2
Menu Configuration
Code 128 Status Default: Disabled Options: Disabled, Enabled
Fixed Code Length 2–Menu Config.
Default: Disabled Options: Disabled, Enabled Allows you to increase data integrity by ensuring that only one label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Allows you to specify the exact number of characters that the scanner recognizes. The scanner ignores any label not having the specified length.
UCC/EAN-128 Status Default: Disabled Options: Disabled, Enabled, Required A subset of Code 128, with extended features. Note: Code 128 must be Enabled for UCC/EAN-128 to function.
With Enabled selected, both Code 128 and UCC/EAN-128 labels are decoded. With Required selected, only UCC/EAN-128 labels are decoded.
Format Default: Standard Options: Standard, Ap. Rec. (Application Record) Allows you to choose between Standard UCC/EAN-128 and Application Record formats. With Standard enabled, UCC/EAN-128 labels are interpreted and output in standard UCC/EAN-128 format. Application Record is a user-definable variation of UCC/EAN-128 that does the following:1 • Separates Application Identifier fields.
2-28
MS-7100/7180 Industrial Scanner User’s Manual
Page 59
Code Types Menu
Application Record Separator Default: Disabled Options: Disabled, Enabled Note: Application Record must be enabled under Format before this parameter can take effect.
When enabled, a separator character is inserted between data fields.
Application Record Separator Default: , (comma) Options: User Defined Note: Application Record must be enabled under Format before this parameter can take effect.
Allows you to define an ASCII character as a separator.
Application Record Brackets Default: Disabled Options: Disabled, Enabled Note: Application Record must be enabled under Format before this parameter can take effect.
When enabled, brackets ( ) are added to enclose application identifiers.
1. When Number of Labels (page 2-18,) is set to greater than One, Application Record Padding must be disabled. If Application Record Padding is enabled, label data will be output in the Standard Format. MS-7100/7180 Industrial Scanner User’s Manual
2-29
2–Menu Config.
• Pads variable length fields (unless disabled) with 0’s until the maximum length is reached (except for the last field of the label). • Passes each Application Identifier and its data field onto the application processing software. • Allows you to add and define separators between data fields, enclose Application Identifier’s in brackets, and disable padding. Note: If an illegal Application Record format is detected, then the scanner will process it as a “noread” message, except that it will output it as a “Bad Format” in place of the noread.
Page 60
Chapter 2
Menu Configuration Application Record Padding Default: Enabled Options: Enabled, Disabled Note: Application Record must be enabled under Format before this parameter can take effect. Note: When Number of Labels (page 2-18,) is set for more than One, Application Record Padding must be disabled. If Application Record Padding is enabled, output will automatically default to Standard Format.
2–Menu Config.
Padding is the insertion of zeros to make up the maximum length of a variable application identifier field, except for the last field which does not require padding. When enabled, padding is included. When disabled, padding is omitted. Note: Padding is never added to fixed length fields or to the last data field of a label. Enabling or disabling padding will have no effect on these.
2-30