Page 61

User Outputs Menu

User Outputs Menu The User Outputs menu allows you to configure the scanner’s output. To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-7. User Outputs

Beeper Volume

Relay Settings

Level 4 – Level 5 – Level 1 – Level 2 – Level 3

On Good – On Noread – Disabled

Bold text represents default settings.

–

–

Relay-Output #1

TTL-Output #2

Mismatch or Noread – Good Match – Mismatch – Noread

Mismatch or Noread – Good Match – Mismatch – Noread

–

–

Output Pulse Width*

Output Polarity Positive – Negative

–

–

Full Screens Enabled – Disabled –

Command Start Character < – User Definable (ASCII Char.) –

New Master Pin

–

Laser On/Off

Reverse Video

Disabled – Enabled

Disabled – Enabled

–

–

K Command Options

50 ms User Definable (0 to 255)

– –

Disabled Enabled

Partial Output

Echo K Cmd Disabled – Enabled –

Beep on K Disabled – Enabled –

Ctrl Char Output Ctrl – Hex –

Status – –

Disabled Enabled

Start Position – –

1 1 to 31

Partial Length – –

31 1 to 31

* The number entered on the command line represents 1/10 actual value in milliseconds.

Figure 2-7 User Outputs Menu Structure

MS-7100/7180 Industrial Scanner User’s Manual

2-31

2–Menu Config.

Beeper Status

–

Page 62

Chapter 2

Menu Configuration

Beeper Status

2–Menu Config.

Default: On Good Options: On Good, On Noread, Disabled On Good is enabled by default. The options are On Good, On Noread, or Disabled. Note: The beeper interrupts operations for approximately 100 ms. We recommend that you disable the beeper in high-speed Multidrop operations since the time delay can cause labels to be missed.

Beeper Volume Default: Level 4 Options: Level 4, Level 5, Level 1, Level 2, Level 3

Relay Settings Relay--Output #1 Default: Mismatch or Noread Options: Mismatch or Noread, Good Match, Mismatch, Noread Allows you to determine the conditions under which internal relay contacts (pins 7 and 9 of the trigger and power connector) will be opened or closed. The TTL level output that drives this internal relay is also available on pin 6 of the host connector and pin 8 of both the trigger and power connectors.1 Selecting:

Has this effect:

Mismatch or Noread

Sends a pulse when the label's data does not match that of the master label, or the label is not decoded before the end of the read cycle.

Good Match

Sends a pulse when the decoded label matches the master label (or any good read if match code is disabled).

Mismatch

Sends a pulse when the label’s data does not match that of the master label.

Noread

Sends a pulse when the label’s data is not decoded before the end of the read cycle.

Note: If Good Match is enabled but Match Code is not enabled (see “Match Code” on page 2-19) then any occurance of a good read will cause a pulse to be output and mismatches will be ignored.

1. Pins 6 and 8 can source or sink 4 mA maximum. Pins 7 and 9 can conduct up to 200 mA or 4VA.

2-32

MS-7100/7180 Industrial Scanner User’s Manual

Page 63

User Outputs Menu TTL--Output #2 Default: Mismatch or Noread Options: Mismatch or Noread, Good Match, Mismatch, Noread Allows you to determine the conditions under which a user-programmable TTL pulse will be output (high or low depending on polarity) to pin 25 of the host connector. Has this effect:

Mismatch or Noread

Sends a pulse when the label's data does not match that of the master label, or the label is not decoded before the end of the read cycle.

Good Match

Sends a pulse when the decoded label matches the master label (or any good read if match code is disabled).

Mismatch

Sends a pulse when the label’s data does not match that of the master label.

Noread

Sends a pulse when the label’s data is not decoded before the end of the read cycle.

Note: If Good Match is enabled but Match Code is not enabled (see “Match Code” on page 2-19) then any occurance of a good read will cause a pulse to be output and mismatches will be ignored.

Output Polarity Default: Positive Options: Positive, Negative Allows you to choose between positive and negative logic signals to pins 6, 8, and 25 on the host connector, to pin 8 on both the trigger and power connectors, and to the internal relay contacts that open or close a switch between pins 7 and 9 on both the trigger and power connectors. When Output Polarity is set to Positive, the switch between pins 7 and 9 on the power and trigger connectors will be normally open (unless closed by an output pulse). Conversely, if Output Polarity is set to Negative, pins 7 and 9 of the power and trigger connectors will be normally closed. Output Pulse Width Default: 5 (.05 seconds). Corresponds to 50 ms displayed in the menu. Options: 0 to 255 (0 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds. Allows you to set the duration of the output pulses to pins 6, 8, and 25 on the 28-pin connector, to pin 8 on both the trigger and power connectors,

MS-7100/7180 Industrial Scanner User’s Manual

2-33

2–Menu Config.

Selecting:

Page 64

Chapter 2

Menu Configuration and to internal relay contacts that open or close a switch between pins 7 and 9 on both the trigger and power connectors. Caution: Too long of a pulse width can cause missed labels, especially if Output Pulse Width exceeds End of Read Cycle Timeout (see page 2-14,).

Full Screens

2–Menu Config.

Default: Enabled Options: Enabled, Disabled Allows you to display either the full menu screen or just the command line. When Full Screens is disabled, only the command line will be displayed.

New Master Pin Default: Disabled Options: Disabled, Enabled Note: Match Code (page 2-19,) and a triggered mode (page 2-13,) must be enabled for New Master Pin to take effect. Allows you to momentarily connect pin 27 to ground (pin 7) in order to clear any existing master label information from memory and to record the next good read as the new master label information.

Laser On/Off Default: Disabled Options: Disabled, Enabled Note: A serial or external trigger (see “Triggering Mode” on page 2-13) must be enabled for Laser On/Off to take effect. When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. Note: Laser On/Off does not relate to the <H> (Enable Laser Scanning) and <I> (Disable Laser Scanning) operational commands discussed under “Device Control Commands” on page 5-3.

Reverse Video Default: Disabled Options: Disabled, Enabled When enabled, the scanner will read bar code labels with bars that are lighter in color than their corresponding backgrounds.

2-34

MS-7100/7180 Industrial Scanner User’s Manual

Page 65

User Outputs Menu

Command Start Character Default: < Options: Any ASCII character (except a NUL). Allows you to define a new ASCII start character in a serial command.

K Command Options

Note: It is important to note that if a command with multiple fields is processed, some of the fields may have been processed properly following an “invalid” command. These changes will be in the string echoed back so that the user will know what did or did not change.

Beep on K Command Default: Disabled Options: Disabled, Enabled When enabled, the scanner beeps once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. Control Character Output Default: Ctrl Options: Ctrl, Hex Determines response to an Echo K or status request command. When set to CTRL, ASCII control character output includes a control character as shown in the “Ctrl” column of Table A-B, “ASCII Table,” on page A-5. When set to Hex, the output is the actual character.

MS-7100/7180 Industrial Scanner User’s Manual

2-35

2–Menu Config.

Echo K Command Default: Disabled Options: Disabled, Enabled When enabled, serial configuration commands (“K” commands) will be processed and the new string for that command will be echoed back to the host. If an invalid command is sent to the host, the scanner will echo back the current setting of that command. For example, if the current Noread Message is “NOREAD” and <Kk1,NONSENSE> is entered, the scanner will echo back: <Kk1,NOREAD>. In this example the attempted entry “NONSENSE” exceeds the maximum allowable seven characters. Therefore it is rejected and the current NOREAD message is echoed back and remains the Noread Message.

Page 66

Chapter 2

Menu Configuration

Partial Output

2–Menu Config.

Status Default: Disabled Options: Disabled, Enabled When enabled, allows you to pre-select portions of labels to be transmitted by the scanner. In multilabel mode, partial output is performed on each separate label. For example, if Start Position is set to 3 and Partial Length is set to 5, the following labels are transmitted as follows: 1234567890 as “34567” 1234 as “34” 1234,abcde as “34,cde” (two labels with separator) 12 as ““ Start Position Default: 1 Options: 1 to 63 Allows you to determine the first character from the beginning of a label to transmit. Partial Length Default: 63 Options: 1 to 63 Allows you to determine the number of characters to be transmitted.

2-36

MS-7100/7180 Industrial Scanner User’s Manual

Page 67

Raster Setup Menu

Raster Setup Menu The Raster Setup menu allows you to set the top and bottom of the raster arc in degrees, control the number of raster sweeps per second, and enable Raster On/Off. Figure 2-8 shows the structure of this menu. Raster Setup

Top Offset In Degrees

Enabled – Disabled –

– –

0 User Definable (0 to 45)

Bottom Offset In Degrees 45 – User Definable (0 to 45) –

Sweeps Per Second – –

Raster On/Off

14 User Definable (0 to 135)

– –

2–Menu Config.

Status

Enabled Disabled

Figure 2-8 Raster Setup Menu Structure

For additional information on raster setup, see Step 4, “Determine Raster Height and Arc,” on page 1-5 and Step 5, “Calculate Number of Scans,” on page 1-6.

Status Default: Enabled Options: Enabled, Disabled

Top Offset in Degrees Default: 0 (degrees) Options: 0 to 45 (in one-degree increments) MS-7180 Raster Scanner

Top Offset= 0°

Raster Arc

Bottom Offset = 45°

Figure 2-9 Raster Sweep Arc

Table 2-2 Raster Settings Raster Arc

1° 5° 10° 15° 20° 25° 30° 35° 40° 45°

MS-7100/7180 Industrial Scanner User’s Manual

Sweeps per Second Minimum Maximum

1 1 1 1 1 1 1 1 1 1

135 75 45 35 29 23 21 19 17 14

2-37

Page 68

Chapter 2

Menu Configuration Note: Top Offset must always be less than the bottom offset or the resulting arc will be 0°.

Bottom Offset in Degrees Default: 0 (degrees) Options: 0 to 45 (in one-degree increments)

Sweeps Per Second 2–Menu Config.

Default: 14 (sweeps per second) Options: 0 to 135 Allows you to control the raster motor speed. A “sweep” is defined as a single pass, up or down, creating the raster image. Table 2-2, “Raster Settings,” on page 2-37 shows minimum and maximum possible sweep speeds at selected raster arcs. The minimum speed at any arc is always one sweep per second (SPS). Note that the maximum sweep speed for the raster arc that you have chosen will not exceed the default, even if you enter a higher speed. To maximize the number of scans a label will receive, it is recommended that as few as possible sweeps per second be selected. However, to ensure that the minimum required scan lines cross the bar code label, it is essential that at least two full sweeps occur during the time it takes for the label to pass through the readable scan width area. For example, if the label is readable in the read range for only 1/10th of a second, then the number of sweeps per second should be at least 20. If readable for only 1 second, then sweeps per second should be at least 2. (To see a formula for calculating sweeps per second, see Step 5, “Calculate Number of Scans,” on page 1-6.)

Raster On/Off Default: Disabled Options:Disabled, Enabled Note: Laser On/Off must be enabled (KC1) for Raster On/Off to take effect. When enabled, the raster will shut off (or turn on) approximately 1.9 ms after a change in the state of the laser. Since this time delay may interfere with certain applications - for example where a trigger has occurred and a read is expected - you can disable Raster On/Off and the raster motor will remain on at all times.

2-38

MS-7100/7180 Industrial Scanner User’s Manual

Page 69

Chapter

3

Serial Configuration Chapter Contents

This chapter describes how to configure the MS-7100/7180 scanner by serial commands from a host.1 All of the configuration parameters that can be changed in the menus with the exception of Full Screens, as described in Chapter 2, “Menu Configuration,” can also be changed by serial configuration commands. All of the serial configuration parameters, with the exception of Trigger Filter Timing Value, also appear in the menus.

1. The scanner communicates in full duplex, terminal mode with no handshake. It also recognizes carriage returns and line feeds. The host or ASCII terminal with must match the following default settings before any communication can take place: 9600 Baud Rate, Seven Data Bits, Even Parity, and One Stop Bit. If communicating from an auxiliary terminal via the auxiliary port (pins18 and 19 of the 28 pin connector, the serial command <D> (Enter Menu Configuration Program) is the only command that the scanner will recognize.

MS-7100/7180 Industrial Scanner User’s Manual

3-1

3–Serial Config.

Summary of Serial Configuration Commands...................................... 3-2 Communications Commands............................................................... 3-5 Operations Commands ........................................................................ 3-9 Code Type Commands ...................................................................... 3-12 User Outputs Commands .................................................................. 3-15 Raster Setup Commands................................................................... 3-17

Page 70

Chapter 3

Serial Configuration

Summary of Serial Configuration Commands Table 3-1 Summary of Serial Configuration Commands Function (Not in menu)

3–Serial Config.

Communications

Operations

Cmd

Command Title

KF

Trigger Filter Timing Value

Format <KF?> (returns current value in milliseconds) <KFtime in 10 ms increments>

Kf

Host Protocol

<Kfprotocol,data,...>

Kd

Preamble

<Kdstatus,ASCII characters>

Ke

Postamble

<Kestatus,ASCII characters> <Kcstatus>

Kc

LRC

KA

Host Response Timeout

<KAnumber>

KB

Intercharacter Delay

<KBnumber>

Ka

Host Port

<Kabaud,parity,stop bits,data bits>

Kb

RS-422

<Kbstatus>

Ky

Aux Port

<Kymode,baud,parity,stop bits,data bits>

KG?1 Comm. Status Request

<KG?1>

Kg

Triggering Mode

<Kgmode>

Kh

End of Read Cycle

<Khmode,time>

Ki

Serial Trigger Character

<Kicharacter>

Kj

External Trigger Polarity

<Kjmode>

Kk

Noread Message

<Kkstatus,message>

Kl

Bar Code Output

<Klstatus,when to output>

Km

Good Decode Reads

<Kmnumber>

Kn

Match Code

KL

Number of Labels

<Kntype,sequential matching,match start position,match

KG?2 Operations Status Request

Code Type length,wild card character,sequence on noread,sequence on every mismatch>

<KLnumber of labels,separator character> <KG?2>

Ko

Narrow Margins/ Symbology ID

<Konarrow margins status,symbology ID status>

Kp

Code 39

<Kpstatus,check digit,check digit output,large interchar gap,fixed length,length>

Kq

Codabar

<Kqstatus,S/S match,S/S output,large interchar gap,fixed length,length>

Kr

Interleaved 2 of 5

<Krstatus,check digit,check digit output, length 1,length 2>

Ks

UPC/EAN

<Ksstatus,EAN status,supplementals status, separator status,separator char.>

Kt

Code 128

<Ktstatus,fixed length,length,UCC/EAN status,format,ap.

KG?3 Code Type Status Request

3-2 rec. separator,ap. rec. separator,ap. rec. brackets,ap. rec. padding>

<KG?3>

MS-7100/7180 Industrial Scanner User’s Manual