Page 41
Communications Menu
RS-422
Aux Port Parameters Allows you to set mode and communications parameters between the scanner and an auxiliary monitor. An auxiliary monitor can be used to configure the menus, send data to the host, and display data transmissions originating from the host or scanner. Note: Aux Port operates in RS-232 only. See Appendix I, “Auxiliary Monitor,” on page A-16 for a full description of auxiliary port options.
Aux Mode Default: Disabled Options: Disabled, Transparent, Half Duplex, Full Duplex, Daisy Chain. Aux Mode (auxiliary mode) allows you to select a communications mode for auxiliary operations (see Appendix I, “Auxiliary Monitor,” on page A-16).
Other Aux Port Parameters The other Aux Port parameters - Baud Rate, Parity, Stop Bits, and Data Bits - are identical to the host port parameters and are changed in the same manner. Note: The Aux Port baud rate should never exceed Host Port baud rate or auxiliary port data could be lost.
MS-7100/7180 Industrial Scanner User’s Manual
2-11
2–Menu Config.
Default: Disabled Options: Disabled Note: Used only in Point-to-Point protocol, and not with RTS/CTS. Enabled Whenever RS-422 is disabled, RS-232 is enabled in the background. However, when Multidrop is enabled, the functioning protocol is RS-485 regardless of the displayed status of RS-422 in the menus. Before enabling RS-422, first double-check that Multidrop is not enabled. (See “Protocol” on page 2-6. (See Appendix H, “Interface Standards,” on page A-15 for additional information on RS-422.)
Page 42
Chapter 2
Menu Configuration
Operations Menu The Operations menu allows you to set the operations parameters for the scanner. To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-3. – Bold text represents default settings.
2–Menu Config.
Operations Triggering Mode
End of Read Cycle
– Continuous Read – Continuous Read 1 Output – External Level – External Edge
TImeout in 10 ms incs.
– Timeout
– 100
– ^]
– New Trigger
– User Definable
– User
– Timeout & New
– Serial Data
Serial Trigger Character
(ASCII char.)
Definable (ASCII char.)
Trigger
– Serial Data & Edge
External Trigger Polarity
Noread Message
Bar Code Output
– NOREAD
– Enabled
– Enabled
– User
– Disabled
– Disabled
Noread Message
– Positive – Negative
Definable (ASCII Chars)
Good Decode Reads
– As Soon As
Possible – End Of
Read Cycle
Number of Labels
Field Separator – , (comma) – User Definable
– 1
– 1
– User Definable
– User Definable
(1-31)
When to Output
(ASCII char.)
(1-6)
Matchcode Match Code Type
Match Code Master
Sequential Matching
– Disabled
– (blank)
– Increment
– Enabled
– User entry
– Decrement
(up to 15 characters)
– Sequential – Wild Card
Match Start Position
Match Length
Wild Card Character
– 0
– 1
– * (asterisk)
– 0 to 31
– 1 to 31
– any ASCII character
Figure 2-3 Operations Menu Structure
2-12
MS-7100/7180 Industrial Scanner User’s Manual
Page 43
Operations Menu
Triggering Mode Default: Continuous Read Options: Continuous Read, Continuous Read 1 Output, External Level, External Edge, Serial Data, Serial Data & External Edge Allows you to establish the type of trigger event that initiates or ends the read cycle. (See “End of Read Cycle” on page 2-14.) Has this effect:
Continuous Read
Trigger input options are disabled and the scanner is always in the read cycle. Bar code data is decoded, and label information is transmitted repeatedly, as long as the label is in the read range of the scanner. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing label or scanner functions.
Note: If Continuous Read is enabled with Match Code, the scanner defaults to Continuous Read 1 Output mode.
Continuous Read 1 Outputa NOTE: Enabling Continuous Read 1 Output when Number of Labels (page page 2-18,) is set to any number greater than one, will cause Number of Labels to default back to one.
Label data is immediately transmitted with Timeout enabled for End Of Read Cycle. If the label doesn't change, the scanner will repeat the output at the end of each subsequent timeout period. For example, if Timeout were set to one second, the scanner would output the label data immediately, and then repeat the output at intervals of one second, for as long as the label continued to be scanned. With Timeout disabled (that is, End Of Read Cycle set to New Trigger), the scanner will output the current label data immediately, but output it only once. A new label appearing at any time in the scan range will produce a new read output as long as the new label is not identical to the previous label.
External Level
Allows a read cycle to be initiated by a trigger signal from an object detector when an object appears within the detector’s range. The read cycle endures until the object moves out of the detector’s range (figure 2-4 on page 2-14) unless a timeout occurs and Timeout is enabled for End of Read Cycle.b
External Edge
As with Level, Edge allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). But unlike Level mode, the removal of an object (falling edge) does not end the read cycle. With Edge enabled, the read cycle ends with a good read output, a timeout, or a new trigger (figure 2-5 on page 2-14).
MS-7100/7180 Industrial Scanner User’s Manual
2-13
2–Menu Config.
Selecting:
Page 44
Chapter 2
Menu Configuration Selecting:
Has this effect:
Serial Data
The scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle.
Serial Data & External Edge
The scanner accepts either an external trigger or a serial ASCII command to start a read cycle.
2–Menu Config.
a. Continuous Read 1 Output will allow an output regardless of how Good Decode Reads is set. b. Level and Edge apply to the active logic state (positive or negative) that exists while the object is in a read cycle, between the rising edge (the appearance of an object) and falling edge (disappearance of the object).
1
First trigger An object, moving in front of the detector beam, causes the first trigger (rising edge trigger) signal to be sent to the decoder, initiating the read cycle.
1
Object detector
Object detector
2
1
Object detector
Second trigger The same object, moving out of the detector's beam, causes a second trigger (falling edge trigger) signal to be sent to the decoder, ending the read cycle.
Figure 2-4 External Level Trigger Signals
Object detector
First rising edge trigger Object #1, moving in front of the detector beam, causes the first trigger (rising edge trigger) signal to be sent to the decoder, initiating the read cycle. Subsequent rising edge trigger Object #2, moving in front of the detector's beam, causes a second trigger (rising edge trigger) signal to be sent to the decoder. This signal initiates a new read cycle and ends the previous read cycle provided that New Trigger or Timeout and New Trigger is enabled and a good read or timeout has not already occurred.
Figure 2-5 External Edge Trigger Signals
End of Read Cycle Default: Timeout Options: Timeout, New Trigger, Timeout & New Trigger Allows you to choose the conditions that will end the read cycle. The read cycle is the time during which the scanner will receive and process label
2-14
MS-7100/7180 Industrial Scanner User’s Manual
Page 45
Operations Menu data. When the Triggering Mode option is set in an External or Serial mode of operation, the trigger event initiates the read cycle. Note: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle. Has this effect:
Timeout
Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger. With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again.
New Trigger
Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event. With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger.
Timeout & New Trigger
Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. An edge or serial trigger also initiates a new read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.
MS-7100/7180 Industrial Scanner User’s Manual
2-15
2–Menu Config.
Selecting:
Page 46
Chapter 2
Menu Configuration
Timeout (in 10 ms incs) 100 (one second). Corresponds to 1000 ms displayed in the menu. Options: 0 to 65535. Divide the number entered on the command line by 100 for time in seconds. Note: Timeout or Timeout & New Trigger under End of Read Cycle (page 2-14,) must be enabled for Timeout (in 10 ms incs) to take effect. Allows you to define the duration of the timeout period.
2–Menu Config.
Default:
Serial Trigger Character Default: ^]. Corresponds to <GS > displayed in the menu. Options:A single ASCII character, including control characters, except a NUL (00H), an existing host command character,1 or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “Defining Special Characters” on page 2-4 and Table A-1, “ASCII Table with Control Characters,” on page A-5. Note: Serial Data (page 2-14) or Serial Data & Edge (page 2-14) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an on-line host command and requires the same command format as all host commands (that is, to be entered within the < > brackets).
External Trigger Polarity Default: Positive Options: Positive, Negative Note: External Level (page 2-13) External Edge (page 2-13) or Serial Data & Edge (page 2-14) must be enabled for External Trigger Polarity to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: If using the Microscan object detector (P/N 99-440001-03), use positive trigger polarity.
1. For example, assigning an upper case D would nullify the <D> (Enter Menu Configuration) command. For a list of operational commands used by the scanner, see table 5-1 on page 5-2.
2-16
MS-7100/7180 Industrial Scanner User’s Manual
Page 47
Operations Menu
Noread Message Default: NOREAD Options: Up to seven ASCII characters Allows you to define any combination of ASCII characters (except a NUL) up to seven characters as the noread message. The noread message, if enabled and if no bar code label has been decoded, will be transmitted to the host at a timeout or the end of a read cycle.
Default: Enabled Options: Enabled, Disabled Note: If Noread Output is enabled, the noread message will only output if Bar Code Output (page 2-17) is also enabled. Allows you to enable or disable the noread message.
Bar Code Output Default: Enabled Options: Enabled, Disabled Allows you to choose whether or not to output label data or a noread to the host. When disabled, a label is decoded and the read cycle transpires as usual, but neither label data nor the noread message is transmitted to the host. Scanner counters are updated, and the current number of good reads or noreads can be obtained via operational commands.
When to Output Default: As Soon As Possible Options: As Soon As Possible, End of Read Cycle Allows you to choose when bar code data is sent to the host. Selecting:
Has this effect:
As Soon As Possible Causes bar code data (good reads) to be transmitted immediately upon a good decode. End of Read Cycle
Causes bar code data output to be delayed until the end of the read cycle.
MS-7100/7180 Industrial Scanner User’s Manual
2-17
2–Menu Config.
Noread Message (enable/disable)
Page 48
Chapter 2
Menu Configuration
Good Decode Reads
2–Menu Config.
Default: 1 Options: 1 to 31 Allows you to select the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure that the value set is within the determined scan rate for the scanning setup so that the scanner is capable of scanning a label the required number of times.
Number of Labels Default: 1 Options: 1 to 6 Note: If Number of Labels is set to any number greater than one while Match Code or Continuous Read 1 Output is enabled, Number of Labels will default back to one. Allows you to choose the number of different labels that the scanner will read during a single trigger event. The labels can be a mix of any enabled bar code symbologies and more than one label can be decoded per scan line. The following conditions apply: 1. Each label must be different to be read. 2. The maximum number of characters in any one label is 51, unless Fixed Code Length is enabled in which case the maximum length is 31. 3. The maximum number of characters in a single scan line is 102. 4. The maximum number of characters for all labels scanned is 255, including preamble, postamble, and all spaces and commas. 5. All noread messages are posted at the end of the data string. 6. If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance.
Field Separator Default: , (comma) Options: Any available ASCII character, except NUL. Allows you to choose the separator character to be inserted between labels.
2-18
MS-7100/7180 Industrial Scanner User’s Manual
Page 49
Operations Menu
Match Code
2. Sending serial command <G> enables the next good read to be the master label. 3. Sending serial command <)XXXX)> downloads data as master label. “Master Label Entry” on page 2-21 shows the sequence of operation (and reference) for setting up and entering master labels. See also “New Master Pin” on page 2-34.
Match Code Type Default: Disabled Options: Disabled, Enabled, Wild Card, and Sequential When not disabled, allows you to enter a master label into the scanner's RAM to be compared with subsequently scanned labels. The results of this comparison determine the scanner’s data and relay outputs, if enabled. The following conditions apply: 1. A triggered mode must be enabled for Match Code Type to take effect. 2. Not disabling Match Code Type when Number of Labels is set to any number greater than one will cause Number of Labels to default back to one. 3. If you wish to send a pulse on a Good Read, Match Code Type must be disabled.
MS-7100/7180 Industrial Scanner User’s Manual
2-19
2–Menu Config.
Default: Disabled Options: Disabled, Match Code Type, Match Code Master, Sequential Matching, Match Start Position, Match Length, Wild Card Character Note: A triggered mode (see“Triggering Mode” on page 2-13) must be enabled for Match Code to take effect. Note: If Match Code is enabled with Continuous Read, the scanner defaults to Continuous Read 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. Note: Enabling Match Code when Number of Labels is set to any number greater than one, will cause Number of Labels to default back to one. Allows you to enter a master label into the scanner's memory to be compared with subsequently scanned labels. With Match Code enabled, a master label can be entered in three ways: 1. With New Master Pin enabled (page 2-34,) toggling pin 27 to ground (pin 7) enables the next good read to be the master label.
Page 50
Chapter 2
Menu Configuration Disabled Disabled has no effect on operations. Enabled Instructs the scanner to compare labels or portions of labels with the master label.
2–Menu Config.
Sequential Instructs the scanner to compare labels or portions of labels for sequential numbers in ascending or descending order. There are four ways to load a master (see “Master Label Entry” on page 221). In every case sequencing occurs after each match. See “Match Code” on page 3-10 for special noread and mismatch sequences. Wild Card Allows you to enter user defined wild card characters in the master label. For example, with wild card defined as the default asterisk, entering URGENT** as your master label will result in matches for URGENT, URGENT1, and URGENT12 but not for URGENT123. As in the above example, when wild cards are appended to the end of the master label, labels of variable lengths can result in matches. However, wild cards in the beginning or center of a label (e.g., UR**NT) do not allow for variable label lengths.
Match Code Master Default: (blank) Options: Displays current master and accepts user entry up to 31 characters. Allows you to edit an existing master or type in a new master label from your keyboard.
Sequential Matching Default: Increment Options: Increment, Decrement Defines the order (ascending or descending) in which labels will be compared when Match Code Type is set to Sequential.
2-20