Page 101
Operational Commands or the last Match Counter Reset command. This counter is always enabled, but will only work as a match count when Match Code option is enabled. If the Match Code option is not enabled, this counter records the number of good reads, or decodes. This count can be requested at any time.1 <W> Match Counter Reset. Sets the Match Counter to 00000. <X> Mismatch Counter. The message X/XXXXX displays the number of labels successfully read that do not match the master label since power-on or the last Mismatch Counter command. <Y> Mismatch Counter Reset. Sets the Mismatch Counter to zero.
Test Commands <C> Enter Read Rate Test. Instructs the decoder to output the percentage of scans decoded. The read rate can vary dramatically due to the angle and location of the label in relation to the scan beam. This test is very useful in aligning and positioning the scanner during installation.
100 %012345 100 %012345 100 %012345 100 %012345
Read Rate Percentage Label Data
<m> Enter Scan Rate Test. Displays the current number of scans per second produced by the spinning mirror.
<J> Exit Read Rate or Scan Rate Test. Ends the read rate test or scan rate test and returns to read or ready mode. Note: Read rate and scan rate are also displayed in the Calibration Setup menu. See “About Calibration,” on page 4-2.
Status Commands <#> Display Software Part Number. Displays software part number. <!> Display Checksum of EPROM. Displays a four-digit hex number (corresponding to a given firmware version) used to verify a scanner’s EPROM.
Master Label Commands
1. Can also be used as a good read counter when Match Code is not enabled. MS-7100/7180 Industrial Scanner User’s Manual
5-5
5–Operations
<E> Enable Operational Commands:master labelMatch Code Option. Identical to Match Code command in Chapter 2, “Menu Configuration,” Instructs the scanner to compare bar code labels being scanned with a master label that has been entered in nonvolatile or volatile RAM, and may under certain conditions open or close an internal relay connected to external pins and send TTL pulses to pins on the host, power, and trigger connectors. (See
Page 102
Chapter 5
Operational Commands “Relay Settings,” on page 2-32.) If no master label has been entered, every decoded label will be a “mismatch” and will increment the mismatch counter by one. Enable Match Code Option is intended for use when the scanner is in a triggered mode. If the Match Code option is enabled in the Continuous Read mode, the scanner defaults to Continuous Read One Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. See “Match Code,” on page 2-19 and “Relay Settings,” on page 2-32. <F> Disable Match Code Option. Disables Match Code. <G> Store Next Label Scanned as Master Label. Causes the scanner to use the next bar code label read as the master label if Match Code option has been enabled. All subsequently decoded labels are compared against the master label information stored in RAM. (See “Match Code,” on page 2-19.) <)XXXX)> Download Master Label Information. Downloads master label information from the host or a terminal. The master label information can be downloaded at any time, and can be saved in nonvolatile memory with a <Z> command. A stored master label will not affect standard operation unless Match Code option is enabled. The Xs denote alphanumeric data, from 1 to 31 characters. <)> Request Master Label Information. Immediately sends the master label information to the host. To prevent conflicts with outputting label data, first send the <I> command (Disable Laser Scanning (Laser Off)).
5–Operations
<))> Delete Master Label Information. Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command. Note: If the master label information has previously been stored in nonvolatile RAM (by a <Z> command), sending an <A> Reset or cycling the power will restore that information.
5-6
MS-7100/7180 Industrial Scanner User’s Manual
Page 103
Appendices
Appendices A
Contents Appendix A, Scanner Specifications ................................................A-2 Appendix B, ASCII Table..................................................................A-5 Appendix C, Orientation ...................................................................A-6 Appendix D, Ground and Shield Considerations..............................A-9 Appendix E, Defaulting the Scanner ..............................................A-10 Appendix F, Troubleshooting .........................................................A-11 Appendix G, Bar Code Symbology.................................................A-14 Appendix H, Interface Standards ...................................................A-15 Appendix I, Auxiliary Monitor..........................................................A-16 Appendix J, Multidrop Communications ..............................................A-21 Appendix K, Glossary of Terms......................................................A-25
MS-7100/7180 Industrial Scanner User’s Manual
A-1
Page 104
Appendices Appendices
Appendix A, Scanner Specifications 2.46 cm.
1.66" 4.21 cm.
2.25" 5.72 cm.
1.13" 2.86 cm. Centerline of raster scan
FRONT
3.06" 7.76 cm.
3.62" 9.20 cm.
1.55" 3.95 cm.
TO P 5.75" 14.59 cm.
TOP
5.33" 13.53 cm.
BACK
Trigger
3.06" 7.76 cm.
3.06" 7.76 cm. Host
Host
Power
5.35" 13.58 cm.
BOTTOM
Power
1.11" 2.82 cm
1.11" 2.82 cm.
3.25" 8.26 cm.
B AC K
Trigger
4.05" 10.30 cm.
5.65" 14.34 cm.
3.25" 8.26 cm 8.72" 22.15 cm
M4 x 0.7 7.1 mmdeep
8.42" 21.39 cm M 4 x 0.7 7.1 m m deep
0.57" 1.45 cm.
4.41" 11.21 cm. 5.56" 14.13 cm.
0.57" 1.45 cm.
0.57" 1.45 cm
4.41" 11.20 cm
0.57" 1.4 5 cm
5.56" 14.12 cm
Figure A-1 MS-7100 Scanner Dimensions
A-2
Figure A-2 MS-710 Raster Scanner Dimensions
MS-7100/7180 Industrial Scanner User’s Manual
Page 105
Scanner Specifications MS-7100: Length: 5.33 in./13.54 cm Height: 3.06 in./7.77 cm MS-7180: Length: 8.72 in./22.15 cm Height: 4.05 in./10.3 cm
Status Lights LED Light Power LED Green None (off) Green Status LED Amber Red Error patterna
Width: 5.56 in./14.12 cm Weight: approx. 3 lbs./1.36 kg Width: 5.56 in./14.12 cm Weight: approx. 4 lbs./1.8 kg
Light Source Type: laser diode Output: visible, 670 nm nominal Operating life: 10,000 hrs. min @ 122°F (50°C)
Scanning Parameters Type: rotating polygon mirror Rate: 600 to 1000 scans/second (standard) Scan width angle: 40°; Pitch: ±50°; Skew: ±40°
Communications RS-232, 422, and 485; ASCII 7 or 8 data bits, 1 or 2 stop bits, 600 to 38.4K baud, selectable parity
Code Types Code 39, Codabar, Interleaved 2 of 5, UPC/EAN, Code 128, Code 49 optional
User Outputs Beeper, 3 relay pulse outputs, match code, two status LEDs
Protocols Point-to-point, XON/XOFF, RTS/CTS, RTS/CTS with XON/XOFF, polling mode D, user defined, multidrop, and user defined multidrop
Environmental Housing: Dust tight case, NEMA12 Operating temp.: 32° to 122°F (0° to 50°C) Storage temp.: –51° to 158°F (–46° to 70°C) Humidity: up to 90% (non-condensing) Ambient light immunity: 450 foot candles (indoor: fluorescent, incandescent, mercury and sodium vapor); 2000 foot candles (outdoors: soft)
Electrical Power supply requirement.: Input 10 to 28 VDC unregulated @ 9W max. with less than 1V p-p ripple
Status On power-on Read cycle (no decode) Read cycle (good decode) Ready (good decode) Ready (no read) Error a Error pattern consists of alternating RED–Normal –GREEN–Normal– NONE-Normal (where “normal” is the background read/ ready condition: none, amber, red, or green)
Options Low density, high density, and ultra high density host connections
I/O Connectors Trigger connections: 1 2 3 4 5 6 7 8 9
Power ground Supply +12 VDC (out) @ 50 mA Optional power input to the scanner (10 to 28 VDC unreg.) Trigger input from the object detector Power ground Optional power input to the scanner (10 to 28 VDC unreg.) Relay contact 1, (200 mA or 4 VA) Relay--output #1 (source or sink 4 mA) Relay contact 2 (200 mA or 4 VA)
Power connections: 1 Power ground 2 Aux. transmit (RS-232) Power input 10 to 28 VDC unreg. @ 9W max. with less than 3 1V p-p ripple 4 Aux. receive data (RS-232) 5 Chassis ground Power input 10 to 28 VDC unreg. @ 9W max. with less than 6 1V p-p ripple 7 Relay contact 1, (200 mA or 4 VA) 8 Relay--output #1 (source or sink 4 mA) 9 Relay contact 2 (200 mA or 4 VA)
MS-7100/7180 Industrial Scanner User’s Manual
A-3
Appendices
Mechanical
Page 106
Appendices
Appendices Host Connections 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Chassis ground Transmit data (RS-232) Receive data (RS-232) Request to send (RS-232) Clear to send (RS-232) Relay--output #1 (source or sink 4 mA) Signal ground (RS-232) Noread +5 VDC out (100 mA max.) Trigger in. (0 VDC to +24 VDC) +12 VDC out (50 mA max.) @ 50 mA –12 VDC out (20 mA max.) @ 50 mA Signal ground Pwr In. (10 to 28 VDC unreg.)
15 16 17 18 19 20 21 22 23 24 25 26 27 28
TXD+ (RS-422/RS-485) TXD– (RS-422/RS-485) Reserved Aux transmit data (RS-232) Aux receive data (RS-232) Power ground RXD + (RS-422/RS-485) RXD – (RS-422/RS-485) Reserved Reserved TTL--output #2 (source or sink 4 mA) Default config. New master CPU master reset
Optical Characteristics
Operating range: 2 to 55 inches (5.1 to 140 cm) depending on density option, label type and size Label contrast: 25% min. absorption dark to light differential at 670 nm Narrow-Bar-Width
Read Range
Maximum Scan Width
.020” .030” .040”
Low Density 6” to 23” (15.2 to 58.4 cm) 4” to 34” (10.2 to 86.4 cm) 10” to 44” (25.4 to 112 cm)
13” (33.0 cm) 18” (45.7 cm) 25” (63.5 cm)
.050” .010” .015” .020”
10” to 55” (25.4 to 140 cm) High Density 6” to 11” (15.2 to 27.9 cm) 5” to 16” (12.7 to 40.6 cm) 3” to 16” (7.6 to 40.6 cm)
7.5” (19.1 cm) 10.5” (26.7 cm) 10.5” (26.7 cm)
.030”
4” to 20” (10.2 to 50.8 cm)
13.5” (34.3 cm)
.040”
4” to 20” (10.2 to 50.8 cm) Ultra High Density 2” to 4.25” (5.1 to 10.8 cm) 2” to 5” (5.1 to 12.7 cm)
13.5” (34.3 cm)
.005” .0075”
34” (86.4 cm)
3.25” (8.3 cm) 3.75” (9.5 cm)
Note: See Figure 1-1, “MS-7100/7180 Ranges and Scan Widths,” on page 1-4.
A-4
MS-7100/7180 Industrial Scanner User’s Manual
Page 107
ASCII Table
Table A-1 ASCII Table with Control Characters Dec
Hex
Mne
Ctrl
Dec
Hex
Ch
Dec
Hex
Ch
Dec
Hex
Ch
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
^ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ ∆
MS-7100/7180 Industrial Scanner User’s Manual
A-5
Appendices
Appendix B, ASCII Table
Page 108
Appendices
Appendices
Appendix C, Orientation Label Orientation If the bar code label bars are parallel to the direction of travel, as shown in figure A-3, the label is said to be in a ladder orientation; if the bars are perpendicular with the direction of travel, the label is said to be in a picket fence orientation (figure A-4).
Ladder Orientation In general, depending on label size and speed, ladder orientation is preferable because different portions of the label are scanned as the label goes by. In addition, label placement is not as critical. As shown in figure A-3, a label can be successfully read if fully placed (including quiet zones) anywhere within the readable portion of the scan line.
Direction of label travel
Scan Line
Figure A-3 Ladder Orientation
Picket Fence Orientation Unlike ladder, picket fence allows only a small portion of the entire label to be scanned. As a result, labels must be of good quality since even slight label imperfections such as extraneous ink, voids, etc., can cause misreads or non-reads.
Direction of label travel
Scan Line
One advantage of the picket fence Figure A-4 Picket Fence Orientation over the ladder orientation is in the area of label speed. In ladder mode, the label travel distance is the height of the bar code; in picket fence mode, the label can be read while it travels the full distance of the scan width. Note: Either ladder or picket fence can be rotated without losing its orientation, provided that the label’s direction of travel does not change in relation to the scan line.
A-6
MS-7100/7180 Industrial Scanner User’s Manual
Page 109
Orientation
The problems associated with picket fence can be minimized by slightly tilting the scan line (figure A-5). This allows a larger portion of the label to be scanned and increases the label placement area by “simulating” the ladder orientation. This of course is impractical with a short bar code height.
Appendices
Angled Picket Fence Orientation
Direction of label travel
Scan Line
Figure A-5 Angled Picket Fence Orientation
Angled picket fence is recommended only where the bar code is reasonably tall and the label speed is not too fast in relation to the scan field width, since angling the label will reduce the number of scans on the label
Object Detector Orientation In a typical operation, a scanner will “look” for bar code data only during a triggered read cycle. A read cycle is initiated by a “trigger” which can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the scanner to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before the object’s label can be scanned by the scanner.
Direction of label travel Detecto r
Alternative detector position
Scanner Label
Figure A-6 Detector Side Orientation
An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the scanner reception.
MS-7100/7180 Industrial Scanner User’s Manual
A-7
Page 110
Appendices Appendices
As the item continues to move down the line, its label moves into the scanner beam and is read by the scanner. Figure A-7 shows a picket fence label being scanned with the detector and scanner at right angles to each other.
Label
Detector Scan beam
Direction of label travel Scanner
Figure A-6 shows a label in Figure A-7 Detector Right-Angle Orientation the ladder direction with the object detector on the same side as the scanner, but positioned so as not to cause interference. • Scan Rate (SR) is the number of scans per second (sps) that a given scanner is capable of emitting. • Scan Width (SW) (picket fence formula only) is the width across the scan beam, at a given distance from the scanner, in which a label can be read. • Label Speed (LS) is the distance per second that a label moves as it Label length travels through the scan lines. • Label Length (LL) (picket fence forLabel mula only) is the length of the longest height printed label to be read plus the length of the quiet zones (figure A-8). Q uiet zones • Label Height (LH) (ladder formula only) is a measurement of the height of Figure A-8 Label Dimension individual bars (figure A-8). • Raster Height (RH) is the distance between the extremities of the scan Scan W idth lines as shown in the raster image in figure A-9. Raster height is generally dictated by the application (range and R aster label placement). Other factors being H eight equal, the greater the raster height, the fewer scan lines available for given label. Figure A-9 Raster Image
A-8
MS-7100/7180 Industrial Scanner User’s Manual