Page 81
MS-3 Laser E.book Page 21 Monday, August 30, 2004 11:09 AM
Chapter 4 Read Cycle
Laser Setup Laser Setup includes Laser On/Off and Laser Framing. Note: See also “Auto Frame” on page 9-6 for more details on laser framing.
Laser On/Off Usage:
Laser On/Off extends the life of the laser. It is useful where there are significant time gaps between symbols. It also provides visual confirmation of a read cycle timeout and minimizes laser exposure to people.
Definition:
When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously.
Serial Cmd:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Laser Framing Status Usage:
Useful in avoiding highly reflective objects, for filtering out unwanted signals, or avoiding the wrong symbols.
Definition:
When Laser Framing is disabled, the laser is ON for 100 percent of the full scan. When enabled, the extent of the laser arc is determined by the Laser On Position and Laser Off Position settings.
Serial Cmd:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
To adjust laser framing automatically, click the Calibration button and click the Auto Frame button. Note: Because scan widths are not always perfectly symmetrical, the most effective way to setup laser framing is to experiment with the Laser On Position and Laser Off Position commands until you get the best results.
MS-3 Laser Scanner User’s Manual
4-21
Page 82
MS-3 Laser E.book Page 22 Monday, August 30, 2004 11:09 AM
Laser Setup
Laser On Position Laser On Position
LASER
Percentage of the full scan arc that the scan beam moves through before the laser turns ON. For example, if set for 30, the laser will be off during the first 30 percent of the scan. When Laser Framing is disabled, the laser is ON for 100 percent of the full scan. When Laser Framing Status is enabled, the laser remains OFF from the start of the scan and remains OFF for the specified percentage of the scan, which is up to 70 percent of the scan, as specified by this command.
MS-3
Definition:
Figure 4-4 Laser On Position
Serial Cmd:
<K700,laser on/off status,laser framing status,laser on position,laser off position,laser power>
Default:
10
Options:
1 to 80
Laser Off Position Laser Off Position
LASER
Percentage of the full scan arc that the scan beam moves through before the laser turns OFF. Notes: The combined values of Laser On Position and Laser Off Position cannot exceed 100 percent, the total arc of one scan. Laser Off Position must always exceed the value of Laser On Position for an actual laser scan to take place.
MS-3
Definition:
Serial Cmd:
Fi 4 5L Off P iti <K700,laser on/off status,laser framing status,laser on position,laser off position,laser power>
Default:
90
Options:
20 to 100
4-22
MS-3 Laser Scanner User’s Manual
Page 83
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Chapter
Symbologies
5 Chapter Contents Symbology by Serial Command ..................................................................5-2 Code 39 .......................................................................................................5-3 Code 128 .....................................................................................................5-6 Interleaved 2 of 5.......................................................................................5-13 Codabar.....................................................................................................5-17 Code 93 .....................................................................................................5-24 Narrow Margins .........................................................................................5-27 Symbology ID ............................................................................................5-28 Background Color......................................................................................5-29 Autodiscriminate ........................................................................................5-29
This section describes the various symbol types that can be read and decoded by the reader. Code 39 is enabled by default. To enable all codes, send a <P> serial command to the scanner from the Terminal window.1 See http://www.aimusa.org/standards/aimpubs.htm for additional information about symbologies. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. 1. If using an I 2/5 symbol, verify that the number of characters in the symbol being scanned matches the code length enabled for the I 2/5 symbol type (default is 10 and 6).
MS-3 Laser Scanner User’s Manual
5-1
Page 84
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
Symbology by Serial Command
Symbology by Serial Command Command Title Code 39 Code 128 Interleaved 2 of 5 Codabar UPC/EAN Code 93 Pharmacode Narrow Margins/ Symbology ID Background Color
5-2
Format <K470, status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set> <K474,status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> <K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode> <K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,fixed symbol length,check digit type,check digit output status> <K473,UPCstatus,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> <K475,status,fixed symbol length status,symbol length> <K477,status,fixed bar length status,fixed bar length,min. no. of bars,bar widths,direction,fixed threshold value> <K450,narrow margins status,symbology ID status> <K451,background color>
MS-3 Laser Scanner User’s Manual
Page 85
MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Code 39 Usage:
Code 39 is considered the standard for non-retail bar code applications.
Definition:
An alphanumeric symbol with unique start/stop symbol patterns, composed of 9 black and white elements per character, of which 3 are wide.
Code 39 Status Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Enabled Note: This is the only symbol type enabled by default.
Options:
0 = Disabled
1 = Enabled
Check Digit Status (Code 39) Serial Cmd:
<K470,code 39 status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Output (Code 39) Usage:
Check Digit Output Status, added to the symbol, provides additional security.
Definition:
When enabled, the check digit character is read and sent along with the symbol data. When disabled, symbol data is sent without the check digit. Note: With Check Digit Output Status and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
5-3
Page 86
MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM
Code 39
Large Intercharacter Gap (Code 39) Usage:
Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since a large intercharacter gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.
Definition:
When enabled, the scanner can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
5-4
1 = Enabled
MS-3 Laser Scanner User’s Manual
Page 87
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Fixed Symbol Length Status (Code 39) Definition:
When enabled, the scanner will check the symbol length against the symbol length field. If disabled, any length is considered a valid symbol.
Serial Cmd:
<K470, status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Symbol Length (Code 39) Usage:
Fixed symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any symbol not having the specified length.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
10
Default:
1 to 64
Full ASCII Set (Code 39) Usage:
Definition:
Serial Cmd: Default: Options:
Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two symbol words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the reader can read the full ASCII character set, from 0 to 255. <K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
MS-3 Laser Scanner User’s Manual
5-5
Page 88
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Code 128
Code 128 Usage:
Code 128 is useful in applications with tight spots and high security needs.
Definition:
A very dense alphanumeric symbology. It encodes all 128 ASCII characters; it is continuous, has variable length, and uses multiple element widths measured edge to edge.
Code 128 Status Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding>
Default:
Disabled
Options:
0 = Disabled
5-6
1 = Enabled
MS-3 Laser Scanner User’s Manual
Page 89
MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Fixed Symbol Length Status (Code 128) Definition:
When enabled, the scanner will check the symbol length against the symbol length field. When disabled, any length is considered a valid symbol.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length,EAN128 status,output format,application record separator status,application record separator character,application record brackets,application record padding>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Symbol Length (Code 128) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only a fixed symbol length will be accepted.
Definition:
Specifies a fixed number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any symbol not having the specified length.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding>
Default:
10
Options:
1 to 64
Note: Fixed Symbol Length Status must be enabled for Symbol Length to take effect.
MS-3 Laser Scanner User’s Manual
5-7
Page 90
MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM
Code 128
EAN-128 Status Note: Code 128 must be Enabled for EAN-128 to function. Usage: Definition: Serial Cmd:
Default: Options:
Used as a standard for shipping symbols. A subset of Code 128, with extended features. (See the Uniform Code Council, Inc. at www.uc-council.org.) <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled 2 = Required
If set to Enabled, symbols can be read with or without a function 1 character in the first position. If set to Required, the symbol must have a function 1 in the first position and conform to EAN format in order to decode the symbol.
5-8
MS-3 Laser Scanner User’s Manual