The text of a manual · part 10 of 25
MS-3 Laser Scanner User's Manual, pages 91 to 100
Pages 91 to 100 of 242
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-3
Page 91
MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Output Format (Code 128) Usage: Definition: Serial Cmd:
Default: Options:
Application Record is useful in applications in which the software can utilize application record formatting to help automate the processing of its EAN-128 data. Offers an option between Standard EAN-128 and Application Record format. <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Standard 0 = Standard 1 = Application Record
In Standard UCC/EAN-128 application identifiers and data fields are sent, but none of the formatting (separators, parentheses, padding) will be included. Application Record is a variation of UCC/EAN-128 that allows the user to define separators between data fields, enclose application identifiers in parentheses, and enable padding (zeros) for variable length fields. Note: If an illegal Application Record format is detected, the scanner will process it as a noread and output a noread message (if enabled).
MS-3 Laser Scanner User’s Manual
5-9
Page 92
MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM
Code 128
Application Record Separator Status (Code 128) Definition: Serial Cmd: Default: Options:
When enabled, a separator character is inserted between application records. <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Note: Output Format must be set to Application Record before this parameter can take effect. Note: When set to Disable, app rec sep char is forced to NUL. When set to Enable, Application Record Separator Character must also be sent in the same command.
Application Record Separator Character (Code 128) Note: Application Record Separator Character Status is enabled by setting the parameter to any value other than a null. Definition: Serial Cmd:
Default: Options:
Allows the user to define an ASCII character as an application record separator. <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> , (comma) User Defined ASCII character
Note: Has no effect unless Application Record Separator Status is enabled.
5-10
MS-3 Laser Scanner User’s Manual
Page 93
MS-3 Laser E.book Page 11 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Application Record Brackets (Code 128) Definition: Serial Cmd:
Default: Options:
When enabled, parentheses ( ) are added to enclose application identifiers. <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Note: Output Format must be set to Application Record before this parameter can take effect.
MS-3 Laser Scanner User’s Manual
5-11
Page 94
MS-3 Laser E.book Page 12 Monday, August 30, 2004 11:09 AM
Code 128
Application Record Padding (Code 128) Definition:
Serial Cmd:
Default: Options:
Padding is the insertion of zeros to make up the maximum length of a variable application record data field, except for the last field which does not require padding. When enabled, padding is included. When disabled, padding is omitted. Note: Padding is never added to fixed length fields or to the last data field of a symbol. Enabling or disabling Record Padding will have no effect on these. <K474,status,fixed symbol length status,fixed symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Note: Output Format must be set to Application Record before this parameter can take effect.
5-12
MS-3 Laser Scanner User’s Manual
Page 95
MS-3 Laser E.book Page 13 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Interleaved 2 of 5 Usage:
It is has been popular because it is the most dense symbol for printing numeric characters less than 10 characters in length; however we do not recommend this symbology for any new applications because of inherent problems such as truncation.
Definition:
A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode I 2/5 symbols.
Interleaved 2 of 5 Status Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
5-13
Page 96
MS-3 Laser E.book Page 14 Monday, August 30, 2004 11:09 AM
Interleaved 2 of 5
Check Digit Status (Interleaved 2 of 5) Usage:
It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification.
Definition:
An error correcting routine in which the check digit character is added.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Output Status (Interleaved 2 of 5) Definition:
When enabled, a check digit character is sent along with the bar symbol data for added data security.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
Disabled
Options:
0 = Disabled
5-14
1 = Enabled
MS-3 Laser Scanner User’s Manual
Page 97
MS-3 Laser E.book Page 15 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Symbol Length #1 (Interleaved 2 of 5) Usage:
With Industrial 2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length #2 to 0 (zero) to ensure data integrity is recommended.
Definition:
Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length. Because Industrial 2/5 is a continuous symbol, it is prone to substitution errors. Hence, a symbol length must be defined and a bar symbol must contain an even number of digits.Note: If start, stop or check digits are used, they are not included in the symbol length count. Note: If Range Mode is set to Enable, the settings for Symbol Length #1 and Symbol Length #2 will define the range of symbol lengths that can be decoded.
Serial Cmd:
<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
10
Options:
0 to 64 Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character.
MS-3 Laser Scanner User’s Manual
5-15
Page 98
MS-3 Laser E.book Page 16 Monday, August 30, 2004 11:09 AM
Interleaved 2 of 5
Symbol Length #2 (Interleaved 2 of 5) Usage:
If using a second symbol, a zero or any even symbol length in the option range may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity.
Definition:
Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length. Note: If Range Mode is set to Enable, the settings for Symbol Length #1 and Symbol Length #2 will define the range of symbol lengths that can be decoded.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
6
Options:
0 to 64 Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character.
Range Mode Status (Interleaved 2 of 5) Usage:
Useful in applications where symbol lengths may vary.
Definition:
Allows user the option to define a symbol length range for I–2 of 5.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,unused,range mode>
Default:
0
Options:
0 = Disabled 1 = Enabled When set to Enabled, minimum and maximum symbol lengths will be defined by Symbol Length #1 and Symbol Length #2.
5-16
MS-3 Laser Scanner User’s Manual
Page 99
MS-3 Laser E.book Page 17 Monday, August 30, 2004 11:09 AM
Chapter 5 Symbologies
Codabar Usage:
Used in photo-finishing and library applications. Formerly used in some medical applications but not typically used in newer applications.
Definition:
Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths.
Codabar Status Serial Cmd:
<K471,status,start & stop match status,start & stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Start & Stop Match Status (Codabar) Usage:
Used to increase security of symbology.
Definition:
Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.
Serial Cmd:
<K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Start & Stop Output Status (Codabar) Usage:
Used to verify matching.
Definition:
Causes the start and stop characters to be transmitted with symbol data.
Serial Cmd:
<K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit status,check digit output status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
5-17
Page 100
MS-3 Laser E.book Page 18 Monday, August 30, 2004 11:09 AM
Codabar
Large Intercharacter Gap (Codabar) Usage:
It is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since enabling Large Intercharacter Gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.
Definition:
Instructs the scanner to read symbols with gaps between characters exceeding three times the narrow element width.
Serial Cmd:
<K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output status>
Default:
Disabled
Options:
0 = Disabled
5-18
1 = Enabled
MS-3 Laser Scanner User’s Manual