Page 101

MS-3 Laser E.book Page 19 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

Fixed Symbol Length Status (Codabar) Usage:

Restricting symbol lengths can help prevent truncations and increase data integrity by ensuring that only one or a defined range of symbol lengths will be accepted.

Definition:

When set to Fixed, the reader will check the symbol length against the Symbol Length field. When set to Any/Minimum, any length is considered a valid symbol. The following rules apply:

Serial Cmd:

<K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output status>

Default:

Any/Minimum

Options:

0 = Disabled

1 = Enabled

Symbol Length (Codabar) Definition:

Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any symbol not having the specified length.

Serial Cmd:

<K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit status,check digit output status>

Default:

10

Options:

1 to 64

Note: Fixed Symbol Length Status must be enabled for Symbol Length to take effect. Note: Because of symbology limitations, setting Symbol Length to any number less than four will produce undetermined results.

MS-3 Laser Scanner User’s Manual

5-19

Page 102

MS-3 Laser E.book Page 20 Monday, August 30, 2004 11:09 AM

Codabar

Check Digit Status (Codabar) Usage:

Modulus 16 is used in the photo-finishing market.NW7 is used in Japanese markets.

Definition:

Allows the user to select the check digit type Codabar will use.

Serial Cmd:

<K471,status,start & stop match,start & stop output status,large intercharacter gap,fixed symbol length status,fixed symbol length,check digit type,check digit status,check digit output status>

Default:

Disabled

Options:

0 = Disabled 1 = Modulus 16

2 = NW 7 3 = Both

Check Digit Output Status (Codabar) Usage:

For additional security a check digit can be added to the symbol.

Definition:

When enabled, the check digit character is sent along with the symbol data. When disabled, symbol data is sent without the check digit.

Serial Cmd:

<K471,status,start & stop match,start & stop output status,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output status>

Default:

Disabled

Options:

0 = Disabled

5-20

1 = Enabled

MS-3 Laser Scanner User’s Manual

Page 103

MS-3 Laser E.book Page 21 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

UPC/EAN Usage:

Definition:

Used primarily in POS application in the retail industry. It is commonly used in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two- or five-digit supplemental symbol data following the normal code. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC version A and UPC version E only.

UPC Status Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> Disabled 0 = Disabled 1 = Enabled

EAN Status Usage: Definition:

Serial Cmd: Default: Options:

EAN is the European version of the UPC symbology and is used in European market applications. EAN is a subset of UPC. When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> Disabled 0 = Disabled 1 = Enabled

MS-3 Laser Scanner User’s Manual

5-21

Page 104

MS-3 Laser E.book Page 22 Monday, August 30, 2004 11:09 AM

UPC/EAN

Supplementals Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:

Reads Supplementals typically used in publications and documentation. A supplemental is a 2 or 5 digit symbol appended to the main symbol. When set to Enabled or Required, the scanner reads supplemental symbol data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required

Disabled UPC Supplementals will not be decoded.

Enabled When enabled, the scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, at the end of the read cycle, the main will be sent by itself. The UPC main and supplemental symbols are considered to be one symbol and will be treated as such.

Required When set to Required and either the main or supplemental symbol is not read, a single noread condition results. The UPC main and supplemental symbols are treated as one symbol. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character, then the data will be displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of symbols should be set accordingly.

5-22

MS-3 Laser Scanner User’s Manual

Page 105

MS-3 Laser E.book Page 23 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

Separator Status (UPC/EAN) Note: UPC must be enabled for EAN to take effect. Usage: Definition: Serial Cmd: Default: Options:

Allows user to distinguish between the main and Supplemental symbols. Allows the user to insert a character between the standard UPC or EAN symbol and the supplemental symbol when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> Disabled 0 = Disabled 1 = Enabled

Separator Character (UPC/EAN) Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Usage: Definition: Serial Cmd: Default: Options:

As required by the application. Allows the user to change the separator character from a comma to a new character. <K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> , (comma) Any ASCII character

Note: Whenever Separator Character is defined as a comma (,) sending a <K473,s ?> command will return the current settings including the separator character comma which appears after the separator status comma.

UPC-E Output to UPC-A (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:

Useful for applications that require UPC-A output. Allows the user to change the output from UPC-E to UPC-A. <K473,UPC status,EAN status,supplementals status,separator status,separator character,unused,UPC-E output as UPC-A> , (comma) Any ASCII character

MS-3 Laser Scanner User’s Manual

5-23

Page 106

MS-3 Laser E.book Page 24 Monday, August 30, 2004 11:09 AM

Code 93

Code 93 Usage: Definition:

Used occasionally in clinical industry. Code 93 is a variable length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces.

Code 93 Status Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 93) Definition: Serial Cmd: Default: Options:

When enabled, the scanner will check the symbol length against the symbol length field. When disabled, any length is considered a valid symbol. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled

Minimum Symbol Length (Code 93) Definition: Default:

When enabled, the scanner will check the minimum symbol length against the minimum symbol length field. When disabled, any length is considered a valid symbol. Disabled

Symbol Length (Code 93) Usage: Definition: Serial Cmd: Default: Options:

5-24

Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any symbol not having the specified length. <K475,status,fixed symbol length status,fixed symbol length> 10 1 to 64

MS-3 Laser Scanner User’s Manual

Page 107

MS-3 Laser E.book Page 25 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

Pharmacode Usage: Definition:

Pharmacode is used mostly with packaging for the pharmaceuticals industry. The symbol encodes up to five different numbers, each with its own color which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999999. In binary format, each input have up to 19 ones and zeros.

Note: It is recommended that you disable AGC before enabling Pharmacode.

Pharmacode Status Serial Cmd: Default: Options:

<K477,status, fixed bar count status,fixed bar count, min. no. of bars,bar widths,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled

Fixed Bar Count Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed bar count status, fixed bar count, min. no. of bars,bar widths,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled

Fixed Bar Count (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed bar count status, fixed bar count, min. no. of bars, bar widths,direction,fixed threshold value> 10 2 to 16

Minimum Bars (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed bar count status, fixed bar count, min. no. of bars, bar widths,direction,fixed threshold value> 4 2 to 16

MS-3 Laser Scanner User’s Manual

5-25

Page 108

MS-3 Laser E.book Page 26 Monday, August 30, 2004 11:09 AM

Pharmacode

Bar Width Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed bar count status,fixed bar count, min. no. of bars, bar widths,direction,fixed threshold value> Mixed 0 = Mixed 1 = Narrow 2 = Wide 3 = Fixed Threshold Value

Direction (Pharmacode) Definition: Serial Cmd: Default: Options:

Specifies the direction that a bar can be read. <K477,status,fixed bar count status,fixed bar count,min. no. of bars, bar widths,direction,fixed threshold value> Forward 0 = Forward 1 = Reverse

Fixed Threshold Value (Pharmacode) Definition: Serial Cmd: Default: Options:

5-26

Used when Bar Width Status field is set to Fixed Threshold Value. <K477,status,fixed bar count status,fixed bar count,min. no. of bars, bar widths,direction,fixed threshold value> 400 1 to 65535

MS-3 Laser Scanner User’s Manual

Page 109

MS-3 Laser E.book Page 27 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

Narrow Margins Usage:

Used when the leading and trailing edges of the symbols are smaller than the standard margin or when other objects encroach into the margins.

Definition:

Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled.

Serial Cmd:

<K450,narrow margins status,symbology id status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Note: Do not use Narrow Margins with Large Intercharacter Gap enabled in Code 39 or Codabar.

MS-3 Laser Scanner User’s Manual

5-27

Page 110

MS-3 Laser E.book Page 28 Monday, August 30, 2004 11:09 AM

Symbology ID

Symbology ID Usage:

Used when the symbology type and how it’s decoded needs to be known.

Definition:

Symbology ID is an AIM standard prefix set of characters that identify the symbol type. When enabled, the reader analyzes and identifies the symbology and adds a three character identifying prefix to the data: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, C, E, I, L, Q, b, d, p, P, M A = Code 39; C = Code 128 or EAN-128; E = UPC/EAN; I = I–2/5; P = Plessy; M = MSI Code 3. Modifier (see Explanation of Modifiers below)

Serial Cmd:

<K450, narrow margins,symbology identifier status>

Serial Cmd:

<K450,0,symbology identifier status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Explanation of Modifiers for Code 39, Codabar, and I–2/5 • For Code 39, Codabar and I–2/5, the modifier indicates Check Digit and Check Digit Output Status. • For Code 39 only, Full ASCII needs to be enabled to see modifiers 4, 5, and 7. Modifier

Check Digit

0 1 3 4 5 7

Disabled Enabled Enabled Disabled Enabled Enabled

Check Digit Output N/A Enabled Disabled N/A Enabled Disabled

Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes

Example:]A5 indicates a Code 39 symbol with Check Digit and Check Digit Output Status enabled and Full ASCII conversion performed.

For Other Codes • For Code 128, a 1 indicates EAN-128; otherwise the modifier is a 0. • For all other codes, the modifier is 0.

5-28