For the Microscan MS-3

Page 111

MS-3 Laser E.book Page 29 Monday, August 30, 2004 11:09 AM

Chapter 5 Symbologies

Background Color Usage:

Definition: Serial Cmd: Default: Options:

If the background is darker than the symbol, then enable black background. Typically the background is white; but on PCBs for example, they can be black. Allows the user to choose which symbol background (spaces and surrounding medium) the scanner can read. <K451,background color> White 0 = White 1 = Black

Autodiscriminate Although Autodiscriminate is not a configuration command, but it is included here as a convenient tool for enabling most symbol types. Usage:

Commonly used for quick setup mode to detect symbol type. This is particularly useful for users who might be unfamiliar with their application’s symbology. Note: It does not alter individual fields such as Start/Stop, Fixed Length, etc. These need to be setup individually.

Definition:

Enables all available symbology types except PDF417, UCC/EAN 128. The user may also individually disable/enable each symbology type.

Serial Cmd:

<P>

Default:

Code 39 (only)

Options:

<P> Enables all codes except noted above. <Q> Enable Code 39 only <R> Enable Codabar only <S> Enable I 2/5 only

Note: If using an I 2/5 symbol, verify that the number of characters in the symbol being scanned matches the symbol length enabled for the I 2/5 symbol type (default is 10 and 6).

MS-3 Laser Scanner User’s Manual

5-29

Page 112

MS-3 Laser E.book Page 30 Monday, August 30, 2004 11:09 AM

Autodiscriminate

5-30

MS-3 Laser Scanner User’s Manual

Page 113

MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM

Chapter

I/O Parameters

6 Chapter Contents Output Conditions by ESP Menu.................................................................6-2 I/O Parameters by Serial Command............................................................6-3 Symbol Data Output ....................................................................................6-4 Message Output ..........................................................................................6-7 Noread Message .........................................................................................6-8 Bad Symbol Message .................................................................................6-9 No Symbol Message .................................................................................6-10 Beeper .......................................................................................................6-11 Partial Output ............................................................................................6-12 Serial Verification ......................................................................................6-13 Test Button ................................................................................................6-15 Output 1.....................................................................................................6-18 Output 2.....................................................................................................6-24 Output 3.....................................................................................................6-25 Quality Output ...........................................................................................6-26 This section includes instructions for setting up conditions for beeper and test button controls and for changing input/output of data messages and electrical transitions for control of internal and external devices. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?>. To see all “K” commands, send <K?>.

MS-3 Laser Scanner User’s Manual

6-1

Page 114

MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM

Output Conditions by ESP Menu

Output Conditions by ESP Menu

Click this Button to bring up the I/O Parameters menu

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

6-2

MS-3 Laser Scanner User’s Manual

Page 115

MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM

Chapter 6 I/O Parameters

I/O Parameters by Serial Command Command Title Symbol Data Output Noread Message Bad Symbol Message No Symbol Message Beeper Partial Output Serial Verification Test Button Output 1 Parameters Trend Analysis (Output 1) Diagnostics (Output 1) Output 2 Parameters Trend Analysis (Output 2) Diagnostics (Output 2) Output 3 Parameters Trend Analysis (Output 3) Diagnostics (Output 3) Quality Output

Format <K705,symbol output status,when to output> <K714,status,noread message> <K715, bad symbol status,bad symbol message> <K716, no symbol status,no symbol message> <K702,beeper output> <K703, partial output status,start postion,length> <K701,serial command echo status,serial command beep status,control/hex output> <K770, global status,default on power-on> <K810,output on,polarity,pulse width,output mode> <K780, trend analysis mode,number of triggers,number to output on,decodes/trigger threshold> <K790,usused,service threshold,unused,laser current high,laser current low> <K811,output on,polarity,pulse width> <K781, trend analysis mode,number of triggers,number to output on,decodes/trigger threshold> <K791,usused,service threshold,unused,laser current high,laser current low> <K812,output on,polarity,pulse width> <K782, trend analysis mode,number of triggers,number to output on,decodes/trigger threshold> <K792,usused,service threshold,unused,laser current high,laser current low> <K704,quality output separator,reads/trigger status>

MS-3 Laser Scanner User’s Manual

6-3

Page 116

MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM

Symbol Data Output

Symbol Data Output Usage:

Useful when the host needs symbol data only under certain conditions.

Definition:

Defines the conditions under which decoded symbols are transmitted to the host.

Symbol Data Output Status Serial Cmd:

<K705,symbol output status,when to output>

Default:

Good Read

Options:

0 = Disabled 1 = Match

2 = Mismatch 3 = Good Read

Note: If set to Match or Mismatch, Symbol Output Status will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Disabled Usage:

Useful when an application only needs to use the discrete outputs and can allow the scanner to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks.

Definition:

When set to Disabled, the scanner will not transmit any data that is generated during a read cycle (symbols, noreads, etc.).

Match Usage:

Match is used in an application that requires specific symbol information and needs to sort, route or verify based on matching the specific symbol data.

Definition:

When set to Match, the scanner transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A noread can still be transmitted if Enabled.

6-4

MS-3 Laser Scanner User’s Manual

Page 117

MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM

Chapter 6 I/O Parameters Mismatch Usage:

Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.

Definition:

With Mismatch enabled, the scanner transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A noread can still be transmitted if enabled.

Good Read Usage:

Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.

Definition:

With Good Read enabled, the scanner transmits symbol data on any good read regardless of Matchcode Type setting. Note: A noread can still be transmitted if enabled.

MS-3 Laser Scanner User’s Manual

6-5

Page 118

MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM

Symbol Data Output

When to Output Symbol Data Definition:

This command allows the user to choose when symbol data can be sent to the host.

Serial Cmd:

<K705,symbol output status,when to output>

Default:

As Soon As Possible

Options:

0 = As Soon As Possible

1 = End of Read Cycle

As Soon As Possible Usage:

As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data.

Definition:

Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good decode, depending on how Decodes Before Output is set.

End of Read Cycle Note: See “End of Read Cycle Mode” on page 4-14 for options to end the read cycle. Usage:

End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded.

Definition:

Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle

Start of read cycle Read cycle Timeout Host activates trigger

This is when host expects output Figure 6-6 Read Cycle

6-6

MS-3 Laser Scanner User’s Manual

Page 119

MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM

Chapter 6 I/O Parameters

Message Output The following flow chart explains the logic paths taken for Noread, Bad Symbol and No Symbol outputs.

Start of Read Cycle

Scans until end of read cycle

Does the scanner decode the symbol?

Notes: When Symbol Detect is enabled, the scanner will test for a minimum number of bar and space transitions as set in Transition Counter Threshold. If that minimum threshold is met, a Bad Symbol message is sent; otherwise a No Symbol message is sent. If conditions for a Bad Symbol, No Symbol, or No Object messages are met but the corresponding output is not enabled, a Noread message will be output.

Yes

No Is Symbol Detect enabled?

No

Noread message sent (if enabled)

Yes

Bad Symbol message sent (if enabled)

Yes Is Transition Counter Threshold met?

No No Symbol message sent (if enabled)

End of read cycle

MS-3 Laser Scanner User’s Manual

6-7

Page 120

MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM

Noread Message

Noread Message Usage:

Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification.

Definition:

When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the noread message will be transmitted to the host.

Noread Status Serial Cmd:

<K714,status,noread message>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Noread Message Definition:

Any combination of ASCII characters can be defined as the noread message.

Serial Cmd:

<K714,status,message>

Default:

NOREAD

Options:

1 to 7 ASCII characters.

Note: Noread Message will only be transmitted if Symbol Output (“Symbol Data Output Status” on page 6-4) is set to Match, Mismatch or Good Read. Noread Message can be set to any ASCII characters except NULL <> and , (comma).

6-8

MS-3 Laser Scanner User’s Manual