Page 121
MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Bad Symbol Message Note: Bad Symbol Message does not apply to multisymbol operations. Usage:
Useful in verifying the presence of a symbol that has not been decoded.
Definition:
When enabled, a message is sent to the host when a symbol is detected but not decoded. See “Transition Counter Threshold” on page 6-8. The Bad Symbol output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is met, a user defined message will be sent to the host. See “Output Message Flow” on page 9-8.
Bad Symbol Status Serial Cmd:
<K715,bad symbol status,bad symbol message>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Bad Symbol Message Serial Cmd:
<K715,bad symbol status,bad symbol message>
Default:
BADCODE
Options:
Up to 10 ASCII characters (except NUL) The Bad Symbol output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is met, a user defined message will be sent to the host.
MS-3 Laser Scanner User’s Manual
6-9
Page 122
MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM
No Symbol Message
No Symbol Message Note: No Symbol Message does not apply to multisymbol operations. Usage:
Useful in determining if an object has an attached symbol.
Definition:
When enabled, sends a message to the host whenever an object is detected but no symbol is detected. The No Symbol output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is NOT met, a user defined message will be sent to the host. See “Transition Counter” on page 4-20.
No Symbol Status Serial Cmd:
<K716,no symbol status,no symbol message>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
No Symbol Message Serial Cmd:
<K716,no symbol status,no symbol message>
Default:
NO_SYMBOL
Options:
Up to 10 ASCII characters (except NUL)
6-10
MS-3 Laser Scanner User’s Manual
Page 123
MS-3 Laser E.book Page 11 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Beeper Usage:
Can be used as an audible verification that either a good read or a noread has occurred.
Definition:
A beep is emitted either after each good read of a symbol or after each noread, according to the Beeper Output Condition selection. Note: Beeper will also sound if any of the following occur: • the scanner is defaulted a send/save command from ESP or an Exit command from any embedded menu. • a <Z>, <Zp>, <Zd>, or <K,1> command is sent
Beeper Output Condition Serial Cmd:
<K702,beeper output>
Default:
On Good Read
Options:
0 = Disabled
1 = On Good Read
2 = On Noread
MS-3 Laser Scanner User’s Manual
6-11
Page 124
MS-3 Laser E.book Page 12 Monday, August 30, 2004 11:09 AM
Partial Output
Partial Output Definition:
When enabled, allows you to pre-select portions of symbols to be transmitted by the scanner.
Usage:
In Multisymbol mode, partial output is performed on each separate symbol. For example, if Start Position is set to 3 and Partial Length is set to 5, the following symbols are transmitted as follows: 1234567890 as 34567 1234 as 34 123456789,abcde as “34567,cde” (two symbols with separator) 12 as [blank]
Status Serial Cmd:
<K703,partial output status,start position,length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Start Position (Partial Output) Definition:
Allows you to determine the first character from the beginning of a symbol to transmit.
Serial Cmd:
<K703,partial output status,start position,length>
Default:
1
Options:
1 to 64
Length (Partial Output) Definition:
Allows you to determine the number of characters to be transmitted.
Serial Cmd:
<K703,partial output status,start position,length>
Default:
63
Options:
1 to 64
6-12
MS-3 Laser Scanner User’s Manual
Page 125
MS-3 Laser E.book Page 13 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Serial Verification Usage:
These commands are useful in removing any doubt about the scanner’s acceptance and response to host configuration commands. For example, if the current preamble is “SOM” and <Kd1, START> is entered, the scanner will echo back <Kd1, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message.
Definition:
Allows the user to verify configuration command status.
Serial Command Echo Status Important Note: ESP will not function whenever this command is enabled. Definition:
When enabled, a configuration command received from the host is echoed back to the host with the resultant settings.
Host
Scanner
Function:
If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/hex output>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
6-13
Page 126
MS-3 Laser E.book Page 14 Monday, August 30, 2004 11:09 AM
Serial Verification
Serial Command Beep Status Important Note: ESP will not function whenever this command is enabled. Usage:
Used to audibly verify the acceptance and validity of a command.
Definition:
Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed.
Function:
If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/hex output>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Control/Hex Output Usage:
Useful for viewing settings with binary characters when using serial command on a terminal.
Definition:
Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a nondisplayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/hex output>
Default:
Control
Options:
0 = Control
6-14
1 = Hex
MS-3 Laser Scanner User’s Manual
Page 127
MS-3 Laser E.book Page 15 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Test Button The test button provides a convenient way to perform programmable operations both globally and for each of the three programmable button positions. The test button has three positions, each of which can be user-programmed to perform a variety of functions.
Global Status Definition:
Determines the basic function of the test button.
Serial Cmd:
<K770,global status,default on power-on>
Default:
Enabled
Options:
0 = Disabled 1 = Enabled 3 = Unlatch Output
2 = Trigger
Disabled: When selected, the test button is disabled. Enabled: When the Test button is enabled, the function of each button position can be determined by the Test Button Mode command. Trigger: When selected, the test button will act as a trigger for the scanner. All other button operations will not be active. The trigger will operate the same way as an external trigger. Trigger mode External Level
External Edge
Operation The read cycle endures for as long as the test button is pressed, unless a timeout occurs and Timeout is enabled for End Of Read Cycle. As with Level, Edge allows a read cycle to be initiated by pressing the test button, but unlike Level mode, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Output. When selected, will unlatch any outputs that have been latched via “Latch Mode 1 (Unlatch on New Master Change)” on page 6-20.
Default on Power-on Definition:
When enabled, if the test button is held down during power-on, the scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command.
Serial Cmd:
<K770,global status,default on power-on>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
6-15
Page 128
MS-3 Laser E.book Page 16 Monday, August 30, 2004 11:09 AM
Test Button
Test Button Modes Definition:
Provides six user-selectable functions for each of the three test button positions.
Serial Cmd:
<K771,position 1 mode,position 2 mode,position 3 mode>
Defaults:
As indicated (table 6-1).
Options:
As indicated (table 6-1).
The positions are selected by the length of time the button is held. When you want to select position one, you press and holds the button until one beep is emitted from the scanner and the 20% LED is turned on. You then release the button to select position one. If you want to select position two, you continue to hold until you hear two short beeps and the 40% LED is turned on. Finally, to select position three, you continue to hold the button until you hear three short beeps and the 60% LED is turned on. For example, if you want to select the function for position three, you will hear one short beep, then two short beeps, and finally three short beeps and the 20%, 40%, and 60% LEDs turn on in progression. The following table lists the options for the three positions with the default position in bold text: Table 6-1 Test Button Options Single Beep 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-on 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-on 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-on 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode
Disabled: When set to Disabled, the button position will have no function associated with it. The scanner will still respond when the button position is reached. Read Rate: Read rate will perform decodes/second and is the same as sending a <C> from the terminal. (See “Read Rate” on page 11-5.) To exit read rate mode, press the test button once quickly. Calibration: The calibration routine will be initiated (see “Calibrate the Reader” on page 1-9). To abort calibration, press the test button once quickly. Save for Power-on: When when this button position is selected, all scanner settings will be saved to non-volatile memory to be recalled when scanner is powered-on the next time. This is the same as sending the <Z> in the terminal.
6-16
MS-3 Laser Scanner User’s Manual
Page 129
MS-3 Laser E.book Page 17 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters Auto Frame: Auto Framing will be initiated when this button position is selected. To abort auto-framing, press the test button once quickly. Auto framing is a background routine that automatically adjusts the scan width to the length of a symbol. This procedure can also be accessed in a terminal view by the <@> command. Load New Master: This allows the button to function the same as the New Master Pin command. The new master pin’s consecutive decode requirement holds true for this button position when this mode is selected. (See“New Master Pin” on page 7-9.) Sleep Mode: If sleep mode is enabled, the test button will shut off the mirror motor and laser. To exit sleep mode, press the test button once quickly.
MS-3 Laser Scanner User’s Manual
6-17
Page 130
MS-3 Laser E.book Page 18 Monday, August 30, 2004 11:09 AM
Output 1
Output 1 Usage:
This option provides switching to host software to control external devices such as PLCs and relays. It is useful for routing and sorting and to prevent mis-packaging and mis-routing.
Definition:
Sets the discrete output functions for specific user-selected conditions.
Output On Definition:
Allows the user to set the conditions under which an output (or outputs) will be activated.
Serial Cmd:
<K810,output on,polarity,pulse width,output mode>
Default:
Mismatch or Noread
Options:
0 = Mismatch or Noread 1 = Match 2 = Mismatch 3 = Noread
4 = Trend Analysis 5 = Validation 6 = Diagnostic Warning
Note: If Output On is set to Mismatch or Noread, Match, or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.
Mismatch or Noread Activates discrete output when the symbol data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.
Match Activates a discrete output when the symbol data matches the master symbol. Note: If you want to output for a good read and Matchcode is not enabled, you can enable any output for Match.
Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.
Noread Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.
6-18
MS-3 Laser Scanner User’s Manual