Page 131
MS-3 Laser E.book Page 19 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters Trend Analysis Tracks the occurrences and frequency of mismatches, noreads, and the number of reads per trigger and output the results to any of three outputs.
Validation (Not yet implemented)
Diagnostic Warning The output remains active as long as one of the diagnostic conditions is met.
Polarity Definition:
Sets the polarity of the discrete output. When set to Negative polarity, and an output condition from the scanner is met, the output-1 pin on the scanner’s 15 pin connector go low for the time specified in Pulse Width. (See Table A-3, “MS-3 Laser Connector, 15-pin Socket,” on page A-4.)
Serial Cmd:
<K810,output on,polarity,pulse width,output mode>
Default:
Negative
Options:
0 = Negative
1 = Positive
Pulse Width Definition:
Sets the time in 1 mS increments that the discrete output remains active.
Serial Cmd:
<K810,output on,polarity,pulse width,output mode>
Default:
50 (50 mS)
Options:
0 to 65535 (0 to 65.535 seconds). Divide the number entered on the command line by 1000 for time in seconds.
MS-3 Laser Scanner User’s Manual
6-19
Page 132
MS-3 Laser E.book Page 20 Monday, August 30, 2004 11:09 AM
Output 1
Output Mode Definition:
Sets the condition in which the discrete output is de-activated.
Serial Cmd:
<K810,output on,polarity,pulse width,output mode>
Default:
Pulse
Options:
0 = Pulse 1 = Latch Mode 1
2 = Latch Mode 2 3 = Latch Mode 3
Pulse Definition:
This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.
Latch Mode 1 (Unlatch on New Master Change) Definition:
The programmable output will be activated when the Output On condition is met and will stay active until the state of the new master pin changes from inactive to active or the configuration button is depressed in the appropriate mode. Important Note: To unlatch using the new master pin the new master pin status must be set to disabled. To unlatch using the button the button status must be set to unlatch mode.
Latch Mode 2 (Unlatch Opposite Condition) Definition:
The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if Noread is enabled under Output On, the programmable output will go active upon a noread and remain active until the opposite condition, a good read, occurs.
Latch Mode 3 (Unlatch Enter Read Cycle) Definition:
The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins.
NOTE: All of the Output On modes are inhibited when any Output on Warning is active for Output 1 (see <K713> command).
6-20
MS-3 Laser Scanner User’s Manual
Page 133
MS-3 Laser E.book Page 21 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Trend Analysis (Output 1) Usage:
Useful in cases in which the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions.
Definition:
Applies trend analysis settings to Output 1. With Trend Analysis, the user can track the occurrences and frequency of mismatches, noreads, and the number of reads per trigger and output the results to any of three outputs.
Example:
Trend analysis mode = Noread Number to Output On = 4 Number of Triggers = 5 In this example, the scanner will activate an output whenever 4 noreads occur within 5 triggers (read cycles).
Trend Analysis Mode Definition:
Sets the trend condition (Mismatch, Noread, or Reads/Trigger) that will activate the output.
Serial Cmd:
<K780,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Default:
Noread
Options:
0 = Mismatch 1 = Noread 2 = Decodes per Trigger
Mismatch Definition:
Output will be activated when the number of Mismatches equals the value entered for Number to Output On within the trigger window selected in Trigger Evaluation Period.
Noread Definition:
The output will be activated when the number of noreads equals the value entered for Number to Output On within the trigger window selected in Trigger Evaluation Period.
MS-3 Laser Scanner User’s Manual
6-21
Page 134
MS-3 Laser E.book Page 22 Monday, August 30, 2004 11:09 AM
Output 1
Number of Triggers (Trend Analysis) Definition:
The number of triggers to examine for the trend analysis condition.
Serial Cmd:
<K780,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Default:
0
Options:
0 to 255
Number to Output On (Trend Analysis) Definition:
Sets the number of Trend Analysis events (mismatches, noreads or reads/trigger as configured by Trend Analysis Mode) to occur within the Number of Triggers before activating the associated output.
Usage:
For example, if Number to Output On is set to 3 and Trend Analysis Mode is set to Noread, then the output will not be activated until 3 noreads have occurred.
Serial Cmd:
<K780,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Default:
0
Options:
0 to 255
Decodes per Trigger (Trend Analysis) Note: This setting only applies when Trend Analysis Mode is set to Decodes per Trigger. Definition:
Sets the threshold for decodes required per trigger (read cycle) that must occur before an output can be activated.
Example:
Trend analysis mode = Decodes per Trigger Number to Output On = 4 Number of Triggers = 25 Decodes per Trigger Threshold = 10 In this example, the scanner will activate an output whenever the number of decodes falls below the decodes per trigger threshold (10) for 4 trigger (read cycle) events.
Serial Cmd:
<K780,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Default:
0
Options:
0 to 65535
6-22
MS-3 Laser Scanner User’s Manual
Page 135
MS-3 Laser E.book Page 23 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Diagnostics (output 1) Applies warning to Output 1. Note: When Diagnostics is enabled (“Output On” on page 6-18), the output mode configuration has no effect. The output will remain active as long as one of the diagnostic conditions is met. The output will go inactive as soon as it detects no active diagnostic warning. Usage:
Alerts user to critical conditions.
Definition:
Sets up the destinations and specific warnings that will cause activation. (See Chapter 8, “Diagnostics” for more information.)
Service Threshold Definition:
Activates the output whenever the service threshold has been met. Will output upon every occurrence of the threshold.
Serial Cmd:
<K790,usused,service threshold,unused,laser current high,laser current low>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Laser Current High Definition:
Activates the output whenever the high current threshold has been met. Will output once.
Serial Cmd:
<K790,usused,service threshold,unused,laser current high,laser current low>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Laser Current Low Definition:
Activates the output whenever the high current threshold has been met. Will output once.
Serial Cmd:
<K790,usused,service threshold,unused,laser current high,laser current low>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
MS-3 Laser Scanner User’s Manual
6-23
Page 136
MS-3 Laser E.book Page 24 Monday, August 30, 2004 11:09 AM
Output 2
Output 2 Serial Cmd:
<K811,output on,polarity,pulse width,output mode>
Output 2 has the same parameters and default settings as Output 1.
Trend Analysis (output 2) Definition:
Applies trend analysis settings to Output 2.
Serial Cmd:
<K781,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Trend Analysis to Output 2 has the same parameters and default settings as Trend Analysis to Output 1.
Diagnostic Warnings (output 2) Definition:
Applies warning to Output 2.
Serial Cmd:
<K791,usused,service threshold,unused,laser current high,laser current low>
Diagnostic Warnings to Output 2 has the same parameters and default settings as Diagnostic Warnings to Output 1.
6-24
MS-3 Laser Scanner User’s Manual
Page 137
MS-3 Laser E.book Page 25 Monday, August 30, 2004 11:09 AM
Chapter 6 I/O Parameters
Output 3 Serial Cmd:
<K812,output on,polarity,pulse width,output mode>
Output 3 has the same parameters and default settings as Output 1.
Trend Analysis (output 3) Definition:
Applies trend analysis settings to Output 3.
Serial Cmd:
<K782,trend analysis mode,number of triggers,number to output on,decodes/trigger threshold>
Trend Analysis to Output 3 has the same parameters and default settings as Trend Analysis to Output 1.
Diagnostic Warnings (output 3) Definition:
Applies warning to Output 3.
Serial Cmd:
<K792,usused,service threshold,unused,laser current high,laser current low>
Diagnostic Warnings to Output 3 has the same parameters and default settings as Diagnostic Warnings to Output 1.
MS-3 Laser Scanner User’s Manual
6-25
Page 138
MS-3 Laser E.book Page 26 Monday, August 30, 2004 11:09 AM
Quality Output
Quality Output Usage:
Host system can monitor scanning performance (printing process, scanning environment changes, etc.) by setting thresholds in their processing or displaying the outputs for visual verification.
Definition:
Allows the host to track the number of good reads per trigger by appending a five digit numeric field to the end of symbol data. When enabled, symbol data is followed by a separator, followed by the five digits in the form of 00000. For example, a certain symbol that has been averaging 00100 reads per read cycle suddenly drops to 00012, this would be a good indication that a problem has arisen even though good reads are still occurring.
Quality Output Separator Serial Cmd:
<K704,quality output separator,reads/trigger status,decode direction status>
Default:
, (comma)
Options:
any ASCII character
Note: For all serial configuration commands, the following characters cannot be used:, < > NUL
Reads/Trigger Status Serial Cmd:
<K704,quality output separator,reads/trigger status,decode direction status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Decode Direction Output Definition:
If enabled the decode direction is appended to the barcode output with a quality output separator as an “F” (forward) or an “R” (reverse).
Serial Cmd:
<K704,quality output separator,reads/trigger status,decode direction status>
Default:
Disabled
Options:
0 = Disabled
6-26
1 = Enabled
MS-3 Laser Scanner User’s Manual
Page 139
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Chapter
Matchcode
7 Chapter Contents Matchcode by ESP ......................................................................................7-2 Matchcode by Serial Command ..................................................................7-2 Overview of Matchcode ...............................................................................7-3 Using Master Symbols.................................................................................7-3 Matchcode Type ..........................................................................................7-4 New Master Pin ...........................................................................................7-9 Master Symbol Database ..........................................................................7-10
This section explains the matchcode output functions and the master symbol database setup. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?>. To see all “K” commands, send <K?>.
MS-3 Laser Scanner User’s Manual
7-1
Page 140
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
Matchcode by ESP
Matchcode by ESP
Click this button to bring up the Matchcode menu.
To change a setting, double-click the setting and use your cursor to scroll through the options.
Matchcode by Serial Command Command Title Matchcode Type New Master Pin Master Symbol Database Size Matchcode Enable Enter data to database Request Master Symbol Information Request all Master Symbol Information Delete Master Symbol Store Next Symbol as Master Symbol
7-2
Format <K223,matchcode type,sequential matching,match start position,match length,wild card character, sequence on noread,sequence on mismatch> <K225,status> <K224,number of master symbols> <K223,status> <K231,master symbol number,master symbol data> <K231?,master symbol number> <K231,?> <K231, master symbol number,> <G master symbol number>
MS-3 Laser Scanner User’s Manual