Page 21
MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM
Chapter 1 Quick Start
Step 8, Calibrate the Reader If, after doing the read rate test, the results are not satisfactory, try the calibration routine. During the calibration routine, the scanner attempts various settings to determine the optimum decode rate for the given conditions. In this process it might do the following: • Adjust laser power • Adjust mirror motor speed • Adjust AGC gain
• Enable Autodiscrimination (read several symbol types)
The test will end automatically when the optimum combination of settings has been achieved.
By ESP Click the Calibrate button in Easy Setup Mode to begin the read rate test.
You can observe the progress of the calibration routine on the Calibration popup. Note: You can also calibrate the scanner in the Calibration menu in the Apps Mode. Test Button TEST
Read rate performance LEDs
100% GR 80% ST 60% 40% 20% PWR
LASER
Press and hold the TEST button until you hear two beeps and see two amber performance LEDs turn amber to indicate that the calibration is in progress. The scanner will beep once at the end of calibration.
MS-3
By the Test button
11-000063-01
Figure 1-4 Calibration
MS-3 Laser Scanner User’s Manual
1-9
Page 22
MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM
Step 9, Save Calibration Settings for Power-on After calibrating the MS-3, you can save your new settings to be available on power-on.
By ESP Caution: If you have settings in the scanner that you have not yet loaded into ESP, the ESP settings will overwrite the scanner’s settings when you save. Under these conditions, it is highly recommended that you first do Receive Reader Settings before you save for power-on. After testing and/or calibrating the scanner, you can save the settings for power-on by clicking the Save button.
Test Button T ES T
Read rate performance LEDs
100% GR 80% ST 60% 40% 20% PWR
LASER
Press and hold the TEST button until you hear three beeps and see three performance LEDs momentarily turn amber.1
MS-3
By the Test Button
1 1- 0000 63-0 1
Figure 1-5 Save Settings
1. This assumes that the default functions of the test button have not been re-programmed.
1-10
MS-3 Laser Scanner User’s Manual
Page 23
MS-3 Laser E.book Page 11 Monday, August 30, 2004 11:09 AM
Chapter 1 Quick Start
Step 10, Configure the Reader See the succeeding chapters and Appendices to see specific configuration command explanations for both ESP and serial commands.
By ESP To change reader settings, or to access the utilities or terminal window, click on the App Mode button.
See Chapter 2, “Using ESP.”
By Serial Commands From your terminal program or the terminal screen in ESP, you can enter serial string commands and configuration and utility commands as described in this manual. See “Serial Configuration Commands” on page A-13 and “Summary of Utilities Commands” on page 11-3. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>.
MS-3 Laser Scanner User’s Manual
1-11
Page 24
MS-3 Laser E.book Page 12 Monday, August 30, 2004 11:09 AM
1-12
MS-3 Laser Scanner User’s Manual
Page 25
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Chapter
Using ESP
2 Chapter Contents Setup Mode .................................................................................................2-2 Application Mode .........................................................................................2-3 Pulldown Menus ..........................................................................................2-4 Connect Menu .............................................................................................2-9 View...........................................................................................................2-11 Navigating in ESP .....................................................................................2-12 Send/Receive Options...............................................................................2-13
This section is designed to help you understand the structure, elements, and application of the ESP (Easy Setup Program). When you start up ESP, unless otherwise specified, you will enter the Setup Mode for initial setup. From there, you move easily into the App Mode (application mode) where you can access several configuration and utilities menus.
MS-3 Laser Reader User’s Manual
2-1
Page 26
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
Setup Mode
Setup Mode In Setup Mode you are presented with the Test option and if appropriate for your application, Calibration. After connecting to your scanner (or reader) the Setup Mode will first appear. This will provide you with instructions specific to your model that will help you in positioning, testing, and if appropriate, calibrating.
Test Click the Test button to start the read rate test for a quick indication of the read capabilities and the limits of your application. When Decodes per Second is unchecked, the test will count the percentage of decodes relative to the number of actual scans. Click Stop to end the test.
Calibrate Some models include a calibration routine that will optimize reads by comparing read rates at various settings in focal lengths, scan speeds, and gain settings.
Test button Click here to change from percentage of good decodes to decodes per second
Calibration is available on some models
Note: This view may be slightly different for each model.
Saves Calibration results (if available)
Ends the read rate test On some models, clicking Auto Discriminate will enable most available symbology types.
2-2
MS-3 Laser Reader User’s Manual
Page 27
MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM
Chapter 2 Using ESP
Application Mode From Setup Mode, you can click on the App Mode button to access specific configuration menus, utilities, and a terminal window where serial commands can be entered.
Note that the App Mode and Setup Mode buttons appear in the same position to allow easy switching between these primary modes. The icons on this toolbar are for operations
Click here to open a terminal window
Click here to access read rate and other utilities
Pulldown menus Click this icon to return to Easy Setup mode Click this icon to return to this view from Utilities or Terminal Click on icons in this toolbar to access configuration menu trees to make specific changes in configuration
Note: This view may be slightly different for each model.
Note: For specific information on any of the icons shown above in the operations bar or configuration bar, see specific chapters in this document.
MS-3 Laser Reader User’s Manual
2-3
Page 28
MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM
Pulldown Menus
Pulldown Menus File New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to your reader. Figure 2-1 shows how settings can be saved and received between ESP and the reader and ESP and the host hard drive. Receive Reader Settings
ESP
Reader Save to Reader
File Save
File Open
Host hard drive
Figure 2-1 How Settings are Saved
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
2-4
MS-3 Laser Reader User’s Manual
Page 29
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter 2 Using ESP
Model In Model you can select between models. When you choose another model, your current connection with your present model will be terminated. To connect to another model, select New Model, choose a new model and click OK. Note that all the models you have enabled by selecting will continue to appear in the Model menu and that the same menu is repeated when clicking the Switch Model icon.
When you save your ESP file, you will be saving the settings of all the models defined in a single ESP file.
MS-3 Laser Reader User’s Manual
2-5
Page 30
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Pulldown Menus
Options You can use the Options menu save memos and set up ESP Preferences. Note: Preferences will be saved and be loaded into ESP when ESP is opened next, whether or not you save the ESP file to the computer.
Preferences General tab Reload Last File At startup, reloads the last file saved to the computer. Show Model Prompt At startup, remembers the last connected model and displays it in the Connecting... dialog whenever you attempt to connect. Skip Easy Mode At startup, Skips the Easy Mode and opens directly in the application mode. Show Connect Prompt At startup, displays the Would you like to connect... prompt. Receive After Connect At startup, loads the reader’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.) Enable ‘Send and Save as Factory Settings’ At startup, enables the Send and Save as Factory option in the Send/Recv command.
2-6
MS-3 Laser Reader User’s Manual