Page 11

MS-3 Laser E.book Page xi Monday, August 30, 2004 11:09 AM

Warning and Caution Summary This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For connection to a UL Listed direct plug-in power unit marked Class 2 and rated at 5 VDC at 2 Amps or greater. European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety EN 60950. WARNING Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser light radiation exposure. WARNING There are no user serviceable parts in the scanner. Opening the scanner voids the Microscan Systems warranty and could expose the user to laser diode power of up to 7 mW.

WARNING The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.

MS-3 Laser Scanner User’s Manual xi

Page 12

MS-3 Laser E.book Page xii Monday, August 30, 2004 11:09 AM xii

MS-3 Laser Scanner User’s Manual

Page 13

MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM

Chapter

Quick Start

11 Chapter Contents Step 1 Hardware Required ..........................................................................1-2 Step 2 Connect the System.........................................................................1-3 Step 3 Position Symbol and Scanner ..........................................................1-4 Step 4 Install ESP .......................................................................................1-5 Step 5 Select Scanner Model ......................................................................1-6 Step 6 Autoconnect .....................................................................................1-7 Step 7 Test for Read Rate...........................................................................1-8 Step 8 Calibrate the Scanner ......................................................................1-9 Step 9 Save Calibration Settings for Power-on .........................................1-10 Step 10 Configure the Scanner .................................................................1-11

This section is designed to get the scanner up and running quickly so the user can get a sense of its capabilities and test sample bar code symbols. Detailed setup information for configuring the scanner for your specific application can be obtained in the subsequent chapters.

MS-3 Laser Scanner User’s Manual

1-1

Page 14

MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM

Step 1, Hardware Required Caution: If using your own power supply (see “Warning and Caution Summary” on page i-xi), be certain that it is wired correctly and supply voltage is 10 to 28 VDC. Incorrect wiring or voltage can cause software or equipment failures.

If connecting to a host with an IB-131 Interface box, you will need the following: Itema Part Number 1 FIS-0003-1XXXG 2 FIS-0001-0035G 3 99-000018-01 4 5 61-300026-03 97-100004-15 6 (90-264 VAC, 24VDC) 7 99-000017-01

Description MS-3 laser scanner IC-332 Interface converter IB-131 Interface box Host computer Null modem configuration cable Power supply Optional object detector a. See figure 1-1 for diagram of system.

1 2 3

Scanner

Host

5

Network

4

6

Figure 1-1 Hardware Required

1-2

MS-3 Laser Scanner User’s Manual

7

Page 15

MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM

Chapter 1 Quick Start

Step 2, Connect the System Caution: • Be sure all cables are connected BEFORE applying power. • Always power down BEFORE disconnecting any cables.

To connect the system, do the following:

4. Connect power supply (6) to the IB-131 “POWER” connector. 5. Apply power to the system.

1 2 3

Scanner

5

6

Network

4

Host

1. Connect the scanner (1) to the “SCANNER” connector on the IC-332 interface converter (2) using the attached 3-foot cable.1 2. Connect the IC-332 directly to the “SCANNER” 15 pin connector on the IB-131 (3). 3. Connect the host computer (4) to the IB-131 “HOST” 25-pin connector via the null modem cable (5).2 (Refer to “IB-131 Interface” on page A-8 for pin connections.)

7

Figure 1-2 Hardware Connections

1. Since power supply is included in the single cabling assembly, the reader cable should not exceed 3 feet. RS232 cabling from the IB-131 to the host can be up to 47 feet provided it does not include power input. 2. If using your own null modem RS232 host cable, be certain that the host’s TxD connects to the reader’s RxD and the reader’s TxD connects to the host’s RxD. MS-3 Laser Scanner User’s Manual

1-3

Page 16

MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM

Step 3, Position Symbol and Scanner Note: Code 39 is the default code type enabled. If you are uncertain as to your symbology type, enable all codes by selecting the Auto Discriminate macro in Terminal mode. 1. Set up a symbol at the scanning distance you are using in your application.1 (See “Read Ranges” on page A-3.) 2. Avoid bright light or IR light from other sources, including other scanners. 3. Pitch symbol or scanner slightly to avoid specular reflection, the return of direct, non-diffused light.

Bar code symbol

Skew axis Tilt axis

Scanner Pitch axis Scan line

Figure 1-3 Symbol/Scanner Position Note: If using an I 2/5 symbol, verify that the number of characters in the symbol being scanned matches the symbol length enabled for the I 2/5 symbol type. (Default is 10 and 6.) See “Interleaved 2 of 5” on page 5-13.

1. Consult table A-1 and table A-2 on page A-3.

1-4

MS-3 Laser Scanner User’s Manual

Page 17

MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM

Chapter 1 Quick Start

Step 4, Install ESP (ESP is short for Easy Setup Program.) With your scanner connected to a host computer with Windows operating system, you can use the ESP to configure and control the reader. 1. Insert your Microscan CD into your computer’s CD drive. 2. Launch Setup.exe under ESP and follow the prompts. If downloading from the web: a) Go to http://www.microscan.com/downloadcenter/ b) Enter company information. c) Select ESP and download to your computer hard drive. d) Extract ESP WinZip files to a directory of your choice. 3. Note where your ESP.exe file is stored on your hard drive. At the end of the install process, you should see the following icon on your desktop:

4. Click the ESP icon to start the program.

MS-3 Laser Scanner User’s Manual

1-5

Page 18

MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM

Step 5, Select Reader Model When you start the program, the following menu will appear.

Note: If you need to select another model later, you can find it in the App Mode under Model on the menu bar. 1. Select MS-3 laser from the menu and click OK. If you do not want to make this selection every time you load ESP, uncheck Show this window at Startup. 2. Select the default name, for example MS-3 Laser-1, or type in a file name of your choice and click OK. 3. Click Yes when the connect to the reader dialog appears.

1-6

MS-3 Laser Scanner User’s Manual

Page 19

MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM

Chapter 1 Quick Start

Step 6, Autoconnect 1. In the Connecting to... dialog, if your communications port is not the default COM1, use the pull down arrow to change your communications port.

2. Click the Start button. When connected, the CONNECTED message will appear in a green box in the status bar on the bottom right of the dialog.

3. If connection fails, enable a different Com port, check connections, and try again. Tip: If you do not see either the CONNECTED or DISCONNECTED message at the bottom of your dialog, try expanding the ESP window horizontally. Important Note: When you connect to the reader, the reader’s settings will be loaded into ESP.

MS-3 Laser Scanner User’s Manual

1-7

Page 20

MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM

Step 7, Test for Read Rate With this test you can learn the percentage of decodes per images captured by observing the LEDs (20% through 100%) on the top of the MS-3 which are active during a read rate test. If the results are not satisfactory, move on to “Calibrate the Reader” on page 1-9.

By ESP After connecting to the scanner, ESP will open in Easy Setup Mode. 1. Click the Test button in Easy Setup Mode to begin the read rate test.

2. Follow the instructions in Easy Setup Mode screen. 3. To end the Read Rate test, click the Stop button. Test Button Read rate performance LEDs

T ES T

100% GR 80% ST 60% 40% 20% PWR

Laser

1. Press and hold the TEST button on the MS-3 until you hear one beep and see one LED momentarily turn amber. This will signal the beginning of the read rate routine.1 2. To end the read rate test press the TEST button and quickly release.

MS-3

By the Test Button

1 1- 0000 63-0 1

1. This assumes that the default functions of the test button have not been re-programmed.

1-8

MS-3 Laser Scanner User’s Manual